![Lynx Side Burner Accessory Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/lynx/side-burner-accessory/side-burner-accessory_use-and-installation-manual_1953874017.webp)
17
gas & electric connections
warning
Never coNNect a gas liNe directly to the accessory. a pressure regulator must
be iNstalled oN all gas equipmeNt. all local codes require it aNd lyNx supplies
the correct regulator with your accessory. removiNg or failiNg to iNstall the
pressure regulator caN result iN fire aNd serious persoNal iNjury aNd will void
the warraNty.
the accessory is factory set to
use either propane (lp) or
natural gas (nat). it is critical
that the gas you use matches
that which the accessory was
set up for. you can verify that by
checking the rating plate.
the rating plate is located on
the heat
shield
behind
the front
panel.
ensure that the gas supplied
meets with the minimum
pressure requirements.
do not operate the accessory on
any gas other than that for which
the accessory has been set.
fuel
wc max
inlet
wc min
under full
load
nat gas
7 in
4 in
lp
14 in
10 in
water Column requirements
Both the regulator and the
manifold orifices have been
tuned for the type of gas
specified on the rating plate.
converting to a different type
of gas requires a conversion
kit which is included with your
side burner accessory and
must be installed by a qualified
technician.
all installation and all instal-
lation parts must conform to
local codes with the national
electrical code, ansi/nfpa
70-1990 and the national
fuel gas code, ansi Z223.1/
nfpa 54 in the u.s. and cga-
B149.1/.2 in canada.
canadian installations must
conform to cga-B149.1/.2
natural gas/propane installation
code. (canada)
natural gas
lynx recommends that only
qualified professionals perform
the required plumbing on this
product.
the gas supply line must be
sized to accommodate the total
BTU requirements of all the
gas-fired equipment that will be
connected to that line.
in no case should pipe less
than 3/4” inside diameter or 1”
outside diameter be used.
►
calculate the total Btu
output of all equipment
and refer to “indeX: gas
supply line Runs” for
allowable run distances.
failure to meet these
minimum requirements may
reduce performance of the
accessory and any other
appliances running on that
supply line.
►
always keep supply line
runs as short as possible.
(see indeX: “gas supply line
runs”)
►
a gas shut-off valve must
be installed in an easily
accessible location by a
qualified plumber.
Gas PlumbinG