Lynx C AD 3100 Скачать руководство пользователя страница 3

Reference Manual C AD 3100 Version 1.1

 

 

Page 3  

 

Warranty 

 

LYNX Technik AG warrants that the product will be free from 
defects in materials and workmanship for a period of two (2) 

years from the date of shipment. If this product proves defective 
during the warranty period, LYNX Technik AG at its option will 

either repair the defective product without charge for parts and 
labor, or will provide a replacement in exchange for the 
defective product. 
 

In order to obtain service under this warranty, customer must 
notify LYNX Technik of the defect before expiration of the 
warranty period and make suitable arrangements for the 
performance of service. Customer shall be responsible for 

packaging and shipping the defective product to the service 
center designated by LYNX Technik, with shipping charges 
prepaid. LYNX Technik shall pay for the return of the product to 
the customer if the shipment is within the country which the LYNX 

Technik service center is located. Customer shall be responsible 
for payment of all shipping charges, duties, taxes and any other 
charges for products returned to any other locations. 
 
This warranty shall not apply to any defect, failure, or damage 

caused by improper use or improper or inadequate 
maintenance and care. LYNX Technik shall not be obligated to 
furnish service under this warranty a) to repair damage resulting 
from attempts by personnel other than LYNX Technik 

representatives to install, repair or service the product; b) to 
repair damage resulting from improper use or connection to 
incompatible equipment; c) to repair any damage or 
malfunction caused by the use of non LYNX Technik supplies; or 

d) to service a product which has been modified or integrated 
with other products when the effect of such modification or 
integration increases the time or difficulty servicing the product. 
 

THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS 
PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR 

IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND 
REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE 

REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS 
WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE 
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTAL 

DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE 
VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH 
DAMAGES. 

Содержание C AD 3100

Страница 1: ...Ver Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www lynx technik com Reference Manual C AD 3100 12 Bit CVBS YC to SDI Converter MiniModules Ver 1 1...

Страница 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Страница 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Страница 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Страница 5: ...r Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Units 15 Settings and Control 16 Switch Settings 16...

Страница 6: ...Reference Manual C AD 3100 Version 1 1 Page 6 This Page is intentionally left blank...

Страница 7: ...hese into 8 or 10 Bit SDI video signals SMPTE 259M C Three separate SDI outputs are provided The Module is dual standard PAL NTSC and Input detection is automatic One passive loop through of the CVBS...

Страница 8: ...Chroma Gain Pedestal and Hue Luma Chroma shaping filter for YC S Video and CVBS modes Luma Chroma Comb filter mode off 3h 5h adaptive Automatic Gain Control mode manual auto reference select CTI Color...

Страница 9: ...2 shows the physical layout of the C AD 3100 MiniModule Connections are made through standard 75 Ohm BNC video connections Module configuration is set via a small dip switch located behind an access h...

Страница 10: ...Reference Manual C AD 3100 Version 1 1 Page 10 Figure 2 Module Layout...

Страница 11: ...ectors Connection is self explanatory We recommend the use of high quality video cable suitable for digital video connections to reduce the risk of interference or errors due to excessive cable attenu...

Страница 12: ...niModule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the module Connector wiring is shown...

Страница 13: ...3010 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with the...

Страница 14: ...ack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is p...

Страница 15: ...connection Signal connections should be made with care please ensure connections are correct and compatible equipment is feeding receiving the signals from the module or damage can result Caution Only...

Страница 16: ...following the table for more detail on the switch function Step through test patterns by toggling SW3 within two seconds Switch Setting Function ON Local control enabled 1 OFF Local control disabled O...

Страница 17: ...sert the internal test signal which will then be present on the SDI outputs When set to OFF this will pass the input video signal Switching twice within two seconds activates the next pattern in the f...

Страница 18: ...AD 3100 Version 1 1 Page 18 Auto Store If no parameters are changed for 10 seconds then the current settings will be written into flash memory automatically this can be seen by the front LED flashing...

Страница 19: ...Chroma Gain 0dB Pedestal 0 Gain 0dB Hue 0 High Q mode If this is the mode of operation required then no adjustments are necessary Enhanced Operation Control An enhanced set of control parameters and a...

Страница 20: ...arm LED There is also a single alarm LED on the front side of the module which is designed for quick and easy indication of a problem condition in installations where visible access to the bottom of t...

Страница 21: ...identified on the control system it is possible to initiate the locate function and flash the module LEDs yellow in the following continuous sequence 3 short flashes Pause 3 short flashes This uses th...

Страница 22: ...s can be stored with remote operation Test color bars color bars over red black signal PLL EQ pathological Performance Quantization 12 bits for Luma and Chroma Frequency Response 0 15 dB 5 0 MHz 0 20...

Страница 23: ...dules with power bricks R PS 3001 R FR 3005 Rack Frame 1 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or can be extended with the R FR 301...

Страница 24: ...001 275 Service If you are experiencing problems or have questions concerning your C AD 3100 MiniModule please contact your local distributor for assistance We offer a fixed cost service exchange pro...

Страница 25: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik man...

Страница 26: ...Reference Manual C AD 3100 Version 1 1 Page 26 Notes...

Отзывы: