![Lynx C AD 3100 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/lynx/c-ad-3100/c-ad-3100_reference-manual_1953880019.webp)
Reference Manual C AD 3100 Version 1.1
Page 19
Factory Preset Condition
The C AD 3100 is delivered preset for the following
mode of operation:
•
CVBS (composite) operation
•
Video re-construction lowpass filter enabled
•
Y full bandwidth
•
Auto clamp
•
Automatic gain luma
(referenced to
black/sync voltage level)
•
Automatic gain chroma
(referenced to
color burst)
•
Chroma filter selected
•
Chroma Gain 0dB
•
Pedestal 0
•
Gain 0dB
•
Hue 0°
•
High Q mode
If this is the mode of operation required, then no
adjustments are necessary.
Enhanced Operation Control
An enhanced set of control parameters and
adjustments are possible when the module is
connected into a LYNX control system or if the
module is connected to the optional Service
Adaptor (R CT 3000), this will enable:
•
Direct access to all of the A/D converters
adjustments and enhanced settings
•
Setting and programming the modules internal
Flash Ram with initialization data (which is
automatically recalled on power up)