Settings and Control
The C AD 3100 is configured via the integral 6-
position dip-switch. This is located on the bottom of
the module and can be accessed through the
cutout provided (fig 2)
Switch Settings
Below the switch settings for the 4-position dip-
switch are defined. Please see the section following
the table for more detail on the switch function.
*Step through test patterns by toggling SW3 (within two seconds)
Switch
Setting
Function
ON Local
control
enabled
1
OFF Local
control
disabled
ON
Studio quality input signals
2
OFF
Low quality input signals
ON
Color Bars / Color Bars over red / Black / pll - EQ
pathological*
3
OFF Input
Video
ON
CVBS (Composite) Input mode select
4
OFF
YC input mode select
ON
This switch has to be in position ON
5
OFF Not
used
ON
CTI (color transition improvement) ON
6
OFF
CTI (color transition improvement) OFF