background image

 

11.  TECHNICAL FEATURES

 

Descriptions 

controller

 

Characteristics 

Supply power to microphones DC18V 
Control the active microphone number 
Allows the connection of up to 64 microphones (expandable up to 254 units) 

Response 

40-18000 Hz 

Inputs 

4 x group microphone input line DIN-8 
1 x TEL in (RCA) 
1 x Aux (RCA) 
8 x Video in (RCA) 

Outputs 

1 x Master  (male XLR3) 
2 x MIX out (RCA x 2) 
1 x TEL out (RCA) 

Power supply 

230 V AC 50/60 Hz, 115W 

Dimension 

488 x 84 x 360 mm, 2 U rack 19” 

G.W 

8kg 

Accessories 

1x 13 m DIN-8 main cable 
1x 1.8 m power cable 
1X 2 m XLR M-F cable 
2x 1.65 m RCA-TRS cable 
2x fuse 
1x manual 

 

 
 

 

 

This  product  complies  with  the  latest  Directive  2014/30/UE  (Electromagnetic  Compatibility) 
according to the following standards: 

EN 55013:2013, EN 55020:2007+A11:2011,  
EN61000-3-2:2014, EN61000-3-3:2013 
 

furthermore, it complies with Directive 2014/35/UE (Low Voltage) 
according to the following standard: 

EN 60065:2014 

 
 
 
 
 

We maintains a policy of constant research and development, therefore we reserve the right to apply improvements to 
existing equipment without prior notice

.                                                                                                                                                                                      

Содержание H-3300 SERIES

Страница 1: ...OWNER S MANUAL DIGITAL CONFERENCE SYSTEM H 3300 SERIES ...

Страница 2: ...AR PANEL FUNCTIONS AND CONTROLS H 3300 4 5 CHAIRMAN AND DELEGATE UNIT FUNCTIONS AND CONTROLS 5 6 INSTALLATION AND CONNECTION 5 7 HOW TO USE THE SYSTEM 7 8 EXTENSION POWER UNIT FRONT PANEL FUNCTIONS AND CONTROLS 9 9 EXTENSION POWER UNIT REAR PANEL FUNCTIONS AND CONTROLS 9 10 EXPANSION UNIT CONNNECTION 10 11 TECHNICAL FEATURES 12 ...

Страница 3: ...d In this way the new owner will be aware of all the installation operating and safety instructions Heed all warnings All warnings on the product and in owner s manual should be adhered to Heed all warnings Follow all instructions All operating and user s instructions must be followed Sentences preceded by symbol contain important safety instruction Please read it carefully DETAILED SAFETY INSTRUC...

Страница 4: ... The power cord must be unplugged from the wall outlet and all the connecting cables should be disconnected as well Do not open this unit Do not attempt to open or repair this unit yourself For any problem not described in this owner s manual please refer to qualified personnel only or consult us or your National Distributor Any improper operation could result in fire or electric shock Damages req...

Страница 5: ...ntilated places Disconnect the power cord during storms or when the unit is not in use In order to prevent fire and reduce risk of electric shock it is necessary to keep the unit far from dripping water Please don t put cups vases or other object containing liquids over the unit In case of interference from source signal THD value will raise over 10 Don t place this unit in a bookshelf or in other...

Страница 6: ...phone units divided on six lines never use more than 30 microphone units on each line Adding four expansion units the system can control up to 254 microphone units Main Functions It directly powers and controls 64 microphone stations President station has priority on others Three operating modes FREE MODE LIMIT MODE and FIFO MODE One microphone input MIC and one line input LINE for external units ...

Страница 7: ... on chairman microphone unit all active delegate microphones will be switched off Voting Electing Sign in Key Electret condenser cardioid microphone Indicator light on active microphone When microphone is active indicator light switches on Socket with screw thread 6 INSTALLATION AND CONNECTION Connect the unit to 230 V AC 50 60 Hz mains Use the connection cables provided to connect the daisy chain...

Страница 8: ...he Y type microphone branch cable male DIN 8 1 5 m and the male DIN 8 connector to the next Y type microphone branch cable female DIN 8 2m to extend the microphones Note Paying attention not to connect more than 30 microphones units to each line and no more than 64 microphone units altogether microphone quantity in one system may decreased according to different microphone type and cable length If...

Страница 9: ...speak simultaneously Once this number of delegates is reached no further delegates will be allowed to intervene until the number of active delegate stations again falls below this limit FIFO MODE When this mode is selected the display will read FIFO MODE First In First Out plus the number of delegates who can speak simultaneously In this mode the controller keeps track of the order in which the de...

Страница 10: ...wed by the check mark When deactivated the display will show X beside this function A OFF MODE All activated DELEGATE stations will be automatically disactivated after 45 seconds of inactivity In order to speak again the delegate will have to press MIC ON OFF again fig 3 ref 2 A OFF MODE X There are no time limits for the activated DELEGATE bases This function does not affect the PRESIDENT base MU...

Страница 11: ...ig 5 POWER Main power on off switch 9 REAR PANEL FUNCTIONS AND CONTROLS Fig 6 AC POWER SOCKET Power 230VAC 50 60Hz FUSE 8A EXPANDER OUTPUT 6 inputs for Chairman Delegate units Each line can be connected to up to 30 units do not connect more than 30 One extension power unit can manage up to 60 units In line Power Switches After connecting the microphones to the system set the switches of the lines ...

Страница 12: ...10 EXPANSION UNIT CONNECTION Method 1 fig 7 Note Be sure to keep the shortest possible distance between the central unit and the last microphone For long distances we advise opting for method 1 ...

Страница 13: ...Method 2 fig 8 ...

Страница 14: ...on 488 x 84 x 360 mm 2 U rack 19 G W 8kg Accessories 1x 13 m DIN 8 main cable 1x 1 8 m power cable 1X 2 m XLR M F cable 2x 1 65 m RCA TRS cable 2x fuse 1x manual This product complies with the latest Directive 2014 30 UE Electromagnetic Compatibility according to the following standards EN 55013 2013 EN 55020 2007 A11 2011 EN61000 3 2 2014 EN61000 3 3 2013 furthermore it complies with Directive 20...

Отзывы: