background image

 

Activation and Deactivation of previous Operating Modes 

Using the 

MODE

 button (

fig. 1 ref. 2)

, select the desired operating mode

 

and press 

SAVE (fig. 1, ref. 4)

. If 

the mode requires a numeric limit of delegates, this can be selected pressing the 

Number 

button (

fig. 1, ref. 

3

) and pressing 

SAVE 

to complete the setup. 

 
 

FUNCTIONS: 

 

 

C. ONLY MODE 

When this function is activated, the display will show “C.ONLY MODE” followed by the check mark “√”. 
When deactivated, the display will show “X” beside this function. 
 
C.ONLY MODE  √:  

When  the  PRESIDENT  presses  the 

PRIORITY

  key

 

(

fig.  3,  ref.  3

),  all  DELEGATES  will  be 

excluded,  and  the  DELEGATE  microphones  will  not  reactivate  when  their 

MIC  ON/OFF

  key  is 

pressed. These will remain excluded until the PRESIDENT again presses the 

MIC ON/OFF

 key. 

 

C.ONLY MODE  X:  

When  the  PRESIDENT  presses  the 

PRIORITY

  key

 

(

fig.  3,  ref.  3

),  all  DELEGATES  will  be 

excluded, but the DELEGATE microphones will be reactivated normally when their 

MIC  ON/OFF 

keys are pushed. 
 

In either case (C.ONLY MODE “√” or “X”), the number of DELEGATES who can speak simultaneously 
will be determined by the previously selected limit. 
 
 

 

A. OFF MODE 

When  this  function  is  activated,  the  display  will  read  A.OFF  MODE  followed  by  the  check  mark  “√”. 
When deactivated, the display will show “X” beside this function. 
 
A.OFF MODE  √:  

All activated DELEGATE stations  will be automatically disactivated after 45 seconds of inactivity. 
In order to speak again the delegate will have to press MIC ON/OFF again (

fig. 3, ref. 2

 

A.OFF MODE  X:  

There are no time limits for the activated DELEGATE bases 

 
This function does not affect the PRESIDENT base 

 
 

 

MUSIC MODE

 

When  this  function  is  activated  the  display  will  read  MUSIC  MODE  followed  by  the  check  mark  “√”. 
When deactivated, the display will show “X” beside this function.” 
 
MUSIC MODE  √:  

When  the  PRESIDENT  presses  the 

PRIORITY

  button  (

fig.  3,  ref.  3

),  the  DELEGATE  speaker 

monitors will reproduce a warning tone.  
 

MUSIC MODE  X:  

When  the  PRESIDENT  presses  the

  PRIORITY

  button  (

fig.  3,  ref.  3

),  the  DELEGATE  speaker 

monitor will not produce a warning tone 
 

 

AUTO CODING 

          Each mic has a number ID which is affected (very important to setup the auto-track and voting function   
 
          Controller:  
          - The controller starts the setup of the mic code by turn on the con hold  and press 

Number  

            

button (

fig. 1, ref. 3

)  

          - For that, use the buttons 

MODE

 and 

Number 

 to select the start number,once the selected start  

            number, press 

SAVE

 button, operator can start coding, usually system setup the code from 1 

          - In general, you assign number 1 to the chairman mic.  
          - The first setting code will  transmitted to all the delegate mic.  
  . 

Содержание H-3300 SERIES

Страница 1: ...OWNER S MANUAL DIGITAL CONFERENCE SYSTEM H 3300 SERIES ...

Страница 2: ...AR PANEL FUNCTIONS AND CONTROLS H 3300 4 5 CHAIRMAN AND DELEGATE UNIT FUNCTIONS AND CONTROLS 5 6 INSTALLATION AND CONNECTION 5 7 HOW TO USE THE SYSTEM 7 8 EXTENSION POWER UNIT FRONT PANEL FUNCTIONS AND CONTROLS 9 9 EXTENSION POWER UNIT REAR PANEL FUNCTIONS AND CONTROLS 9 10 EXPANSION UNIT CONNNECTION 10 11 TECHNICAL FEATURES 12 ...

Страница 3: ...d In this way the new owner will be aware of all the installation operating and safety instructions Heed all warnings All warnings on the product and in owner s manual should be adhered to Heed all warnings Follow all instructions All operating and user s instructions must be followed Sentences preceded by symbol contain important safety instruction Please read it carefully DETAILED SAFETY INSTRUC...

Страница 4: ... The power cord must be unplugged from the wall outlet and all the connecting cables should be disconnected as well Do not open this unit Do not attempt to open or repair this unit yourself For any problem not described in this owner s manual please refer to qualified personnel only or consult us or your National Distributor Any improper operation could result in fire or electric shock Damages req...

Страница 5: ...ntilated places Disconnect the power cord during storms or when the unit is not in use In order to prevent fire and reduce risk of electric shock it is necessary to keep the unit far from dripping water Please don t put cups vases or other object containing liquids over the unit In case of interference from source signal THD value will raise over 10 Don t place this unit in a bookshelf or in other...

Страница 6: ...phone units divided on six lines never use more than 30 microphone units on each line Adding four expansion units the system can control up to 254 microphone units Main Functions It directly powers and controls 64 microphone stations President station has priority on others Three operating modes FREE MODE LIMIT MODE and FIFO MODE One microphone input MIC and one line input LINE for external units ...

Страница 7: ... on chairman microphone unit all active delegate microphones will be switched off Voting Electing Sign in Key Electret condenser cardioid microphone Indicator light on active microphone When microphone is active indicator light switches on Socket with screw thread 6 INSTALLATION AND CONNECTION Connect the unit to 230 V AC 50 60 Hz mains Use the connection cables provided to connect the daisy chain...

Страница 8: ...he Y type microphone branch cable male DIN 8 1 5 m and the male DIN 8 connector to the next Y type microphone branch cable female DIN 8 2m to extend the microphones Note Paying attention not to connect more than 30 microphones units to each line and no more than 64 microphone units altogether microphone quantity in one system may decreased according to different microphone type and cable length If...

Страница 9: ...speak simultaneously Once this number of delegates is reached no further delegates will be allowed to intervene until the number of active delegate stations again falls below this limit FIFO MODE When this mode is selected the display will read FIFO MODE First In First Out plus the number of delegates who can speak simultaneously In this mode the controller keeps track of the order in which the de...

Страница 10: ...wed by the check mark When deactivated the display will show X beside this function A OFF MODE All activated DELEGATE stations will be automatically disactivated after 45 seconds of inactivity In order to speak again the delegate will have to press MIC ON OFF again fig 3 ref 2 A OFF MODE X There are no time limits for the activated DELEGATE bases This function does not affect the PRESIDENT base MU...

Страница 11: ...ig 5 POWER Main power on off switch 9 REAR PANEL FUNCTIONS AND CONTROLS Fig 6 AC POWER SOCKET Power 230VAC 50 60Hz FUSE 8A EXPANDER OUTPUT 6 inputs for Chairman Delegate units Each line can be connected to up to 30 units do not connect more than 30 One extension power unit can manage up to 60 units In line Power Switches After connecting the microphones to the system set the switches of the lines ...

Страница 12: ...10 EXPANSION UNIT CONNECTION Method 1 fig 7 Note Be sure to keep the shortest possible distance between the central unit and the last microphone For long distances we advise opting for method 1 ...

Страница 13: ...Method 2 fig 8 ...

Страница 14: ...on 488 x 84 x 360 mm 2 U rack 19 G W 8kg Accessories 1x 13 m DIN 8 main cable 1x 1 8 m power cable 1X 2 m XLR M F cable 2x 1 65 m RCA TRS cable 2x fuse 1x manual This product complies with the latest Directive 2014 30 UE Electromagnetic Compatibility according to the following standards EN 55013 2013 EN 55020 2007 A11 2011 EN61000 3 2 2014 EN61000 3 3 2013 furthermore it complies with Directive 20...

Отзывы: