Microphone:
- This coding information is displayed on all the microphone LCD, press the on/off button of the
corresponding mic to the affected the number.
- The other mics are always show the coding information but with an incremented number of a unit.
- All mic LED
(fig. 3, ref. 6)
will start flash during setup code, the LCD will off after setup code.
- Please restart the system to save the system code setup of mic
Activation/Deactivation of functions
Select a function using the scroll button
MODE
(
fig. 1, ref. 2)
and activate/disactivate pressing the
SET
button (
fig. 1, ref. 3)
8. EXTENSION POWER UNIT FRONT PANEL FUNCTIONS AND CONTROLS
Fig.5
①
POWER: Main power on/off switch
9. REAR PANEL FUNCTIONS AND CONTROLS
Fig.6
①
AC POWER SOCKET: Power 230VAC 50/60Hz , FUSE 8A
②
EXPANDER OUTPUT: 6 inputs for Chairman/Delegate units. Each line can be connected to up to
30 units (do not connect more than 30). One extension power unit can manage up to 60 units.
③
In-line Power Switches: After connecting the microphones to the system, set the switches of the
lines involved on the “I” position. The LED light will indicate that the line is powered.
④
EXSPANDER LINK IN: Connect this input to one of the 4 controller outputs using the cable
Provided
⑤
EXSPANDER LINK OUT:Connect this output to the next expansion unit input using the provided
cable There is no limit to the number of expansion units that can be connected, yet the total
number of manageable microphone units must not exceed 254.