Installation Procedure, LXE Models 6723 Bridge & 6730 AP (RoHS)
NEMA Type 4 Enclosure Reference Guide
E-EQ-NEMARG-F
159089-0001-R Rev. A
Page 12 of 15
35. Remove at least 2” inches of the outer covering from the cut end of the cord.
See figure 18.
36. Remove 0.4” (10 mm) of the insulation from each conductor.
37. Insert the conductors into the terminal block on the right side. Neutral
(marked blue), Live (unmarked), Ground to Ground (marked green). See
figure 19.
Figure 19 Right side connection shown.
Neutral
Marked Blue
Live
Unmarked
Ground
Marked Green
Figure 18
2”
Содержание Nema 4
Страница 4: ......
Страница 8: ...iv Table of Contents NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 20: ...12 Accessories NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 42: ...34 Installation Procedure LXE Model 6520 AP non RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 106: ...98 Installation Procedure LXE Models 6723 Bridge 6730 AP non RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 118: ...110 Installation Procedure LXE Models 6723 Bridge 6720 AP non RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 134: ...126 Installation Procedure LXE Model 6520 AP RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 198: ...190 Installation Procedure LXE Models 6723 Bridge 6730 AP RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 210: ...202 Installation Procedure LXE Models 6723 Bridge 6720 AP RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 216: ...208 Installation Procedure Lightning Suppression Accessories RoHS NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...
Страница 220: ...212 Index NEMA Type 4 Enclosure Reference Guide E EQ NEMARG F ...