3.2.2
Setting LX 1600 (1)
This is a very important setting which defines global vario operation parameters.
•
Vario
needle filter
in steps from 1 to 10.
•
Vario
range
2.5, 5 or 10 m/s or adequate in knots.
•
Averager
integration
time.
•
TE filter
, filter of SC indicator in SC mode, no function by TE level 0% setting.
•
TE level
0% means vario compensation via TE probe and, every setting higher than 0%
means electrical TE compensation, default setting is 100%. During a test flight in calm atmosphere adjust
the value. In general compensation to low, increase the value and vice versa.
•
Smart filter
is additional filter which could be added after selection of more than 0.
•
Mode
defines manner of change over to SC, external means switch connected to SC wire coming out of
Vario unit 15 P connector. Taster variant is also possible in that case a change will happen after each press.
•
Switch style
defines open or closed switch status to get SC.
•
TAB, defines
death area of audio
by SC, around zero.
•
Speed
defines change over speed for SC after Auto speed was selected in Mode.
Additional explanations:
Connection of TE /Pst inlet by tube and by electronic TE compensation
External switch configuration (closed or open active)
Doesn’t matter
Not active
TE(Pst)
SC, marked
cable
Shield
Wire