GB
GeneRAl
INFORMATION
is set with the thermostat dial (figure 4 B). The green
led (figure 4 C) is lit when the radiator is emitting
heat. if the set temperature does not correspond to the
achieved temperature, the thermostat can be adjusted by
pulling the thermostat dial (figure 4 B) straight out and
reinserting it so that the arrow points at the measured
room temperature.
•
if the red led is lit or flashes (figure 4 d), a fault has been
detected by the electronics. Contact your supplier.
•
The radiator is provided with a lockable panel. it can be
locked by moving the catch as per figure 5.
4. MAINTENANCE, REpAIR
AND DISpOSAL
•
WARNING
: disconnect electrical supply before carrying
out any maintenance activity.
•
The product can be cleaned using a soft damp cloth.
do noT use chemical or abrasive cleaners as they will
damage the surface finish.
•
The radiator is equipped with an overheat protection
that cannot be reset (melt fuse). This overheat protection
disconnects the current if the radiator becomes too hot
(e.g. when covered) or if, when freestanding, is knocked
over and left in this position.
•
if the supply cord is damaged, it must be replaced by
the manufacturer, his service agent or similar qualified
persons in order to avoid a hazard.
•
The radiator is filled with an exact amount of
environmental friendly vegetable oil. Any repairs that
require the radiator to be opened shall therefore only
be carried out by the manufacturer or his approved
agent. please contact the manufacturer or his agent
in case of leakage.
•
when scrapping the radiator, follow the regulations
concerning the disposal of oil.
5. WARRANTy
The product is covered by a 10 years warranty except for
the electrical and electronic components that are covered
by a 2 years warranty.
6. TECHNICAL
CHARACTERISTICS
MEASURING ACCURACy
0.1°C
OpERATING TEMpERATURE
STORAGE TEMpERATURE
-10°C to + 50°C
-30°C to + 70°C
SETTING TEMpERATURE RANGE
+5°C to + 30°C
CONTROL CHARACTERISTICS
pi & pwm
2°K proportional band
ELECTRICAL pROTECTION
Class 1 – ipX4
pOWER SUppLy
230 vAC – 50 hz or 400 vAC –
50 hz according to the product
rating label.
CONTROLS CONSUMpTION
0 w when off
~ 7 w at 230 vAC
~ 11 w at 400 vAC
OUTpUT
TRiAC 230 & 400 vAC 8A
DIRECTIVES & STANDARDS:
The thermostat has been
designed to comply with
the following Directives and
Standards.
• en 60730-01
• en 61000-6-1
• en 61000-6-3
• en 61000-4-2
• lv directive 2006/95/Ce
• emC directive 2004/108/Ce
27
|
LVI0019_Manual Kaba_ZW_v5.indd 27
17-01-14 09:47
Содержание KABA
Страница 9: ...9 pRodUCT INFORMATION 3C 3B 1 2 3 4 5 3D LVI0019_Manual Kaba_ZW_v5 indd 9 17 01 14 09 47 ...
Страница 10: ...pRodUCT INFORMATION 10 4 5 D B C A LVI0019_Manual Kaba_ZW_v5 indd 10 17 01 14 09 47 ...
Страница 11: ...KABA LVI0019_Manual Kaba_ZW_v5 indd 11 17 01 14 09 47 ...
Страница 28: ...Notes notes 28 LVI0019_Manual Kaba_ZW_v5 indd 28 17 01 14 09 47 ...
Страница 29: ...29 NOTES notes LVI0019_Manual Kaba_ZW_v5 indd 29 17 01 14 09 47 ...
Страница 32: ...LVI0019_Manual Kaba_ZW_v5 indd 32 17 01 14 09 47 ...