6. Technical Data  

Parameter Symbol 

Symbol 

Condition 

Min. 

Typ. 

Max. 

Unit 

DRIVER POWER SUPPLY SPECIFICATIONS 

Input Power Supply Voltage 

V

S

 

CW 

10 

12 

14 

Input Power Supply Current 

I

S

 

CW 

Input Power Supply Voltage Ripple and 

Noise 

𝛾

 

CW 

200 

mVpp 

CONSTANT CURRENT MODE 

Operating Current Range 

I

OP

 

CW 

T

OP 

= 25˚C

 

T

TEC 

= 21˚C

 

0.05A 

1A 

mA 

Max. Forward Voltage 

2.6 

Current Setting Resolution 

R

IOP_SET

 

0.1 

mA 

SLED Current Reading Resolution 

R

IOP_READ

 

0.1 

mA 

MODULATION MODE 

Waveform 

Square 

Modulation Frequency Range 

f

mod

 

0.016 

Duty Cycle 

10 

50 

90 

INTERNAL MONITOR DIODE 

Monitor Diode Current Reading 

I

mon

 

500 

uA 

Monitor Diode Current Reading 

Resolution 

RES

Imon

 

7.6 

nA 

LIGHT OUTPUT CONNECTOR 

Type of Fiber Connector 

FC/PC, 

FC/APC, 

SMA 

SLED TEC SPECIFICATIONS 

SLED TEC Temperature Setpoint 

T

SLED_SET

 

40 

°C 

SLED TEC Temperature Setpoint 

Resolution 

R

TSLED_SET

 

0.1 

°C 

SLED TEC Temperature Reading 

T

SLED_READ

 

-40 

100 

°C 

SLED TEC Temperature Reading 

Resolution 

R

TSLED_ READ

 

0.1 

°C 

TEMPERATURE SPECIFICATIONS 

Heatsink Temperature Reading Range 

T

HS

 

-40 

100 

°C 

Heatsink Temperature Reading 

Resolution 

R

THS

 

0.1 

°C 

POWER METER 

Spectral Response Range 

λ

PM

 

900 

1870 

nm 

Photosensitive Area 

A

PM

 

Φ1

 

mm 

Power Meter Current Reading 

P

PM

 

50 

uA 

Содержание ASM002501

Страница 1: ...Document LUX Single SLED_V2_ISB1 UM 2021_01_01 2020 User Manual Single Channel Superluminescent Diode Light Source Single SLED Integrated Spectral Bench ISB1...

Страница 2: ...products and technology Quality Policy At Luxmux we use only the highest quality components manufactured consistently to our stringent specifications After assembly we test each system in house before...

Страница 3: ...ED ISB1 Register Map 24 5 Fiber Coupling 25 6 Technical Data 26 7 Dimensions 28 7 1 Dimensions Single SLED Standard 28 7 2 Dimensions Single SLED Standard with Power Meter 29 7 3 Dimensions Single SLE...

Страница 4: ...is powered by a standard FC APC connector FC PC or SMA available upon request The central wavelength of the light output ranges from 1300nm to 1680nm thereby delivering high power densities across th...

Страница 5: ...zards Do not obstruct the air ventilation slots If any parts of the driver or electronics are broken or exposed contact Luxmux technical support and do not attempt to operate the unit The ISB1 is a Cl...

Страница 6: ...il you have inspected the contents and the unit mechanically and electrically Verify that you have received the following items within the package 1 Single SLED Integrated Spectral Bench 1 Power suppl...

Страница 7: ...D Figure 1 Power Side Panel When the unit is plugged in for power and the power button is in the I ON position the power LED of the front panel will light up The ISB1 can be powered up with the power...

Страница 8: ...connection to USB RS232 or Ethernet is required and the SLED can be turned ON OFF with the SLED source control When turning the SLED on or off in MANUAL MODE it will be driven at its default current s...

Страница 9: ...ED is enabled and users can turn it on When the SLED is turned on and light is being emitted the green ON LED will light up If the ISB1 is controlled through the Luxmux software the SLED control will...

Страница 10: ...the ISB1 Unit Air circulation is located on the back panel of the ISB1 Light Source while additional ventilation holes are located in the front panel Ensure vents are not obstructed to allow for maxi...

Страница 11: ...st be specified when placing an order If the ISB1 is controlled through the Luxmux software current and power is displayed in the UI as explained in the Software Operation section Otherwise if using L...

Страница 12: ...dows 7 32 bit 64 bit Windows 8 32 bit 64 bit Windows 10 32 bit 64 bit 3 4 Software Operation When starting up the software will automatically scan your computer s ports and find the Single SLED ISB1 P...

Страница 13: ...buttons on the left of the slider The user can also manually type the desired set current by typing a desired value in the SLED Current box underneath the sliding bar When the unit is turned on the SL...

Страница 14: ...user Can enable modulation for the SLED Note that if the SLED modulation setting is in the OFF position no current will be sent to the SLED even if modulation mode is enabled Maximum Modulation Curren...

Страница 15: ...TEC Capacity represents how hard the TEC is working to maintain the temperature of the SLED At 100 capacity the TEC is working at its maximum capacity to maintain this temperature Figure 9 TEC Control...

Страница 16: ...s enabled these values will be logged in the logfile Graph space can be cleared at any time without losing the data on the logfile by clicking Clear By clicking Stop the power meter will stop graphing...

Страница 17: ...Communications button from the main console When software loads up the Auto Scan function will run to find the virtual com port settings for a USB RS232 and or Ethernet connection Users can manually e...

Страница 18: ...as TX data send and RX data receive messages accompanied by their time stamps This is the raw data sent and received from the software to your Single SLED unit and is used to monitor communications Th...

Страница 19: ...og File button or the data can be appended to an existing file with the button Selecting Existing File After the filename and path have been selected to start logging the logging will start automatica...

Страница 20: ...new value Clicking this button will store the new value recorded in the New Setting field as its new default start up setting The new value will be stored in the Single SLED ISB1 and not on the user...

Страница 21: ...x is not liable for damage if the SLED is operated at higher than specified current ratings The section SLED TEC Controls allows users to change the default settings for the TEC temperature set point...

Страница 22: ...About button in the main console The About window is shown in Figure 14 The software name and version are shown underneath Luxmux s logo Based on the ISB1 model the Capabilities column shows the func...

Страница 23: ...e Application Data Unit ADU 4 1 Serial MODBUS RTU USB interface RS232 MODBUS over Serial Line is a master slave protocol and is employed by the USB port The ADU packet structure for each serial interf...

Страница 24: ...tion Identifier Protocol Identifier Length and Unit Identifier UI The Transaction Identifier indicates a specific MODBUS request response transaction and must be unique at each given time This allows...

Страница 25: ...5 Fiber Coupling The Single SLED is internally optimized for maximum coupling efficiency with PM1550 XP PM1300 XP or SMA 28e based on the model See table below for recommended fiber based on model ty...

Страница 26: ...ge fmod 0 016 Duty Cycle D 10 50 90 INTERNAL MONITOR DIODE Monitor Diode Current Reading Imon 500 uA Monitor Diode Current Reading Resolution RESImon 7 6 nA LIGHT OUTPUT CONNECTOR Type of Fiber Connec...

Страница 27: ...wer Meter TEC Temperature Setpoint Resolution RTPM_SET 0 1 C Power Meter TEC Temperature Reading TPM_READ 40 85 C Power Meter TEC Temperature Reading Resolution RTPM_ READ 0 1 C GENERAL Operating Temp...

Страница 28: ...28 7 Dimensions 7 1 Dimensions Single SLED Standard Overall dimensions for the connector venting locations and mounting holes...

Страница 29: ...29 7 2 Dimensions Single SLED Standard with Power Meter Overall dimensions for the connector venting locations and mounting holes...

Страница 30: ...30 7 3 Dimensions Single SLED Low DOP Overall dimensions for the connector venting locations and mounting holes...

Страница 31: ...31 7 4 Dimensions Single SLED Low DOP with Power Meter Overall dimensions for the connector venting locations and mounting holes...

Страница 32: ...the diagnostic file follow these steps 1 While your unit is connected and running click on the About button on the main screen to open the About window 2 Click Create New Diagnostic File button and sa...

Страница 33: ...ned from LUXMUX that do not comply with the warranty and which are returned to LUXMUX during the applicable warranty period will be repaired or replaced at LUXMUX s option provided the reseller or end...

Страница 34: ...ber removed or altered The warranty does not cover abuse of the product including but not limited to neglect damage or mis use such as water damage back reflection broken fiber incorrect input voltage...

Страница 35: ...iode ISB Integrated Spectral Bench PCB Printed Circuit Board TEC Thermal Electric Cooler ESD Electrostatic Discharge API Application Protocol Interface PDU Protocol Data Unit ADU Application Data Unit...

Страница 36: ...36 12 Ordering Code 12 1 Standard Single SLED models...

Страница 37: ...r An Integrated InGaAs Power Meter can be added to Single SLED models upon customer request The power meter adapters can come with FC APC FC PC or SMA connectors Please indicate on the order if custom...

Отзывы: