1.  Using this manual - general

This manual (hereinafter referred to as the “Manual”) is intended to be used as work of reference for professional, well 
trained and authorised users to be able to safely install, use, maintain and repair the product mentioned on the cover of 
this document (hereinafter referred to as the “Product”). The observation of the Manual does not dispense the user from 
the observance of the local safety instructions and regulations other than provided by the Manual. Such safety instruc-
tions and regulations must be observed at all time. 

For information about specific adjustments, maintenance or repair jobs which are not dealt with in this manual, please 
contact your Product supplier or Luxibel.

If you suspect that the Product is damaged or detect a potential or actual danger when using the Product, immediately 
discontinue use of the Product and contact your supplier of the Product.

WARNING

When in operation the product will emit internal UVC radiation. UVC radiation is invisible to 
humans and exposure to UVC radiation may cause serious damage to eyes and skin. 

The floodlights contain a small amount of mercury which can be poisonous at certain con-
centrations

Avoid:

 

ƒ

direct or indirect lighting on eyes or skin of humans or animals;

 

ƒ

exposure to direct or strongly reflected UVC light.

Basic safety instructions

To minimise the risk of injury, the following basic safety precautions should be observed with each use of the 

product:

1.  Before use, read and save all notices, warnings and safety instructions received with the Product;
2.  Before each use, inspect the Product for damage and verify the proper functioning of its safety features; do not oper-

ate the Product if in case of actual or suspected damage or if its safety features do not function properly;

3.  Select Product mounting locations that prevent exposure of persons and vulnerable components to the UVC-light, 

such as by placing the on/off switch elsewhere than in direct exposure to UVC-Light. If that is not possible, minimize 
the exposure to UVC-light and use adequate personal protection and protect vulnerable components with UV resist-
ant material;

4.  Before performing any service or maintenance always unplug the Product and disconnect the power supply;
5.  Manage the disposal of the Product and in particular of the floodlights with care and according to your local disposal laws;
6.  In case of actual or suspected damage to the floodlights, immediately ventilate and leave the room until it is ventilated; 
7.  Place warning signs near all access panels or doors to a space containing the Product;

Содержание B Air

Страница 1: ...ithout further notice No rights can be derived from this manual No part of this manual may be reproduced in any form or by any means without prior written consent from AED Distribution NV Belgium Luxi...

Страница 2: ...he product as described herein contains components that emit UVC light Immediate or prolonged exposure to UVC light can result in painful injury such as eye injury skin burn premature skin aging or sk...

Страница 3: ...ry which can be poisonous at certain con centrations Avoid direct or indirect lighting on eyes or skin of humans or animals exposure to direct or strongly reflected UVC light Basic safety instructions...

Страница 4: ...must strictly observe the instructions set out herein If you are an employee or are acting on be half of another person your employer that person must instruct you in accordance with the Manual and e...

Страница 5: ...s may no longer emit the required level of ultraviolet radiation to ensure the desired effect on bacteria or fungi Technical data Type B Air Voltage 230 V 50 Hz power factor 0 989 Isolation Class I re...

Страница 6: ...perature range from 15 C to 25 C 6 3 Remove the shipping assembly Remove the tape from the box and open the box Take the unit out of box and remove wrapping that protects the unit Make a visual inspec...

Страница 7: ...disconnected prior to connecting the unit or making any changes to cabling con figurations Electrical installation must be carried out correctly by authorized electricians Standard 230V 50Hz Brown Li...

Страница 8: ...disconnect the power supply Clean the external surfaces with a soft cloth and non aggressive cleaning agents only 8 1 Air filters Luxibel recommends to clean out the airfilters at least twice a year...

Страница 9: ...e from the holders 7 Insert the new lamp with the dowels into the slots of the holders and rotate it about 90 around the axis to lock it 8 Slide unit back inside and reconnect earth cable 9 Install th...

Страница 10: ...nd working methods known to us at the time of issue of the manual and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instruct...

Страница 11: ...AED Distribution NV Bedrijvenpark De Veert 13 004 2830 Willebroek Belgium 32 3 860 76 50 info luxibel com www luxibel com www AEDgroup com...

Отзывы: