6.6 UVC fixture installation
The unit must be attached to a flat surface by means of at least 2 mounting pins, preferably near electrical wires with
grounding.The mounting pins and surface must be strong enough to hold 4 times the weight of the unit.
N
N
L
L
N
N
LL
DA
DA
DA
DA
6.7 Wiring the Product to power source
UVC lamps must be operated continuously from a separate, dedicated, 230V power source.
Ensure main power is disconnected prior to connecting the unit or making any changes to cabling con-
figurations.
Electrical installation must be carried out correctly by authorized electricians.
Standard: 230V 50Hz
Brown = Line cable
Yellow green = Earth cable
Blue = Neutral cable
This device is a class 1 electrical isolation and must be earthed.
6.8 Testing the Product
Test the Product before putting it to use. When you power up the unit, you should hear the fan running. The B air has a
glass B in his logo, this “B” will glow green/blue when lamps are operational.
If the UVC lamp colour changes to red or if the lamp flickers, replace the lamp.
6.9 Operation of the unit
When power is put on the main leads according to electrical specifications, the unit will turn on.