700678-LTG-E-0415
6
Johnson Controls Unitary Products
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
*Denotes IEER rating, not SEER - IEER (Integrated Energy Efficiency Ratio) measures part-load cooling performance due to local occupancy schedules, building con-
struction, building location and ventilation requirements in accordance with ANSI/AHRI 340/360 (units rated at or above 65,000 BTU [19,000 W]).
TCJD42S4(3,4)S4(E)
MV20D
24.5
FC64D
1400
42.0
30.8
14.50
12.25
MX16CN21
21.0
FC/MC43C
1400
41.5
30.0
13.75
11.75
MX16CN21
21.0
FC/MC48C
1400
42.0
30.2
13.80
11.85
MX16CN21
21.0
FC60C
1400
42.0
30.0
13.80
11.80
MX20DN21
24.5
FC/MC48D
1375
42.5
30.4
14.25
12.00
MX20DN21
24.5
FC/MC60D
1375
42.0
30.2
14.25
12.00
MX20DN21
24.5
FC/MC62D
1400
42.5
31.0
14.50
12.25
MX20DN21
24.5
FC64D
1400
44.0
32.0
14.75
12.50
TCJD48S4(3,4)S3(E)
AHE48D
24.5
–
1600
47.0
34.6
13.75
11.50
AHR48D
24.5
–
1610
48.0
34.6
13.00
11.00
AHV48D
24.5
–
1585
47.5
34.0
13.25
11.50
AHV60D
24.5
–
1570
48.0
35.0
13.50
12.00
MV16C
21.0
FC/MC48C
1600
48.0
35.0
13.50
12.00
MV16C
21.0
FC60C
1625
47.5
34.6
13.50
11.50
MV20D
24.5
FC/MC48D
1600
48.0
35.0
13.50
12.00
MV20D
24.5
FC/MC60D
1600
48.0
35.0
13.50
12.00
MX16CN21
21.0
FC/MC48C
1600
48.5
35.0
13.65
11.75
MX16CN21
21.0
FC60C
1600
48.5
34.6
13.25
11.75
MX20DN21
24.5
FC/MC48D
1525
48.5
34.8
14.00
12.00
MX20DN21
24.5
FC/MC60D
1525
49.0
35.0
14.00
12.25
TCJD60S4(3,4)S4(E)
AHE60D
24.5
–
1835
56.5
41.1
13.50
11.50
AHR60D
24.5
–
1620
55.0
39.1
13.00
11.00
AHV60D
24.5
–
1635
55.0
39.1
13.50
11.50
MV20D
24.5
FC/MC60D
1845
55.5
39.6
13.25
11.25
MV20D
24.5
FC/MC62D
1855
56.0
40.6
13.25
11.25
MV20D
24.5
FC64D
1855
57.5
42.1
13.75
11.50
MX20DN21
24.5
FC/MC60D
1725
55.0
38.7
13.70
11.50
MX20DN21
24.5
FC/MC62D
1750
56.0
40.2
13.95
11.75
MX20DN21
24.5
FC64D
1750
57.5
41.7
14.25
12.10
TCJD76S43S3
NH-07
–
–
2600
74.0
53.3
12.60 *
11.20
TCJD76S44S3
NH-07
–
–
2600
74.0
52.5
12.80 *
11.20
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
WIDTH
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.
13 SEER AC WITH AIR HANDLERS