700678-LTG-E-0415
28
Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
TCJD60S4(3,4)S4(E)
INDOOR COIL MODEL NO.
FC/MC/PC60
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
ID CFM
1600
1800
2000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
55.5
61.1
59.4
62.4
64.9
57.7
62.9
60.1
63.8
66.9
59.9
64.7
60.8
65.3
68.8
S.C.
54.5
49.8
40.0
39.7
28.6
56.4
52.4
42.4
41.2
30.8
58.3
54.9
44.9
42.7
32.9
KW
3.68
3.73
3.74
3.76
3.80
3.77
3.81
3.81
3.85
3.88
3.86
3.90
3.89
3.94
3.95
75
T.C.
54.5
58.5
56.4
60.1
63.1
56.6
60.3
57.4
61.6
65.0
58.8
62.2
58.4
63.1
66.8
S.C.
52.1
48.7
39.2
38.7
28.5
53.9
51.3
41.6
40.4
30.4
55.8
53.9
44.1
42.1
32.4
KW
4.14
4.17
4.17
4.21
4.26
4.23
4.25
4.25
4.29
4.34
4.31
4.34
4.33
4.38
4.42
85
T.C.
53.4
55.9
53.3
57.7
61.4
55.5
57.8
54.7
59.3
63.1
57.7
59.7
56.0
60.8
64.8
S.C.
49.7
47.6
38.3
37.7
28.4
51.5
50.2
40.8
39.6
30.1
53.2
52.8
43.2
41.5
31.8
KW
4.59
4.61
4.60
4.66
4.71
4.68
4.69
4.69
4.74
4.80
4.77
4.77
4.77
4.82
4.89
95
T.C.
52.4
53.4
50.3
55.4
59.6
54.4
55.3
51.9
57.0
61.2
56.5
57.2
53.6
58.6
62.7
S.C.
47.3
46.5
37.5
36.7
28.4
49.0
49.1
40.0
38.8
29.8
50.6
51.8
42.4
40.9
31.2
KW
5.05
5.05
5.03
5.10
5.17
5.13
5.13
5.12
5.18
5.26
5.22
5.21
5.21
5.26
5.35
105
T.C.
49.4
50.0
46.7
51.7
55.4
51.7
52.0
48.3
53.3
57.2
54.0
53.9
50.0
54.9
58.9
S.C.
44.6
44.4
36.2
35.2
26.9
46.3
46.6
38.6
37.4
28.4
48.0
48.9
41.0
39.5
29.8
KW
5.64
5.63
5.61
5.70
5.78
5.73
5.72
5.70
5.78
5.87
5.83
5.81
5.80
5.86
5.97
115
T.C.
46.6
46.7
43.3
48.1
51.4
49.1
48.7
44.8
49.7
53.3
51.5
50.8
46.4
51.3
55.2
S.C.
42.0
42.3
34.9
33.8
25.4
43.7
44.2
37.3
36.1
27.0
45.5
46.1
39.7
38.3
28.5
KW
6.21
6.20
6.17
6.29
6.37
6.32
6.30
6.27
6.37
6.47
6.42
6.40
6.36
6.45
6.57
125
T.C.
43.7
43.5
39.8
44.5
47.3
46.4
45.5
41.3
46.1
49.4
49.1
47.6
42.9
47.7
51.5
S.C.
39.3
40.3
33.7
32.5
24.0
41.1
41.8
36.0
34.7
25.6
43.0
43.2
38.3
37.0
27.2
KW
6.79
6.77
6.73
6.87
6.96
6.90
6.88
6.83
6.95
7.06
7.01
6.98
6.93
7.03
7.16
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Air Handlers
Coils
T.C.
S.C.
KW
–
FC/MC/PC60
1.00
1.00
1.00
–
FC/MC62
1.01
1.03
1.01
–
FC64
1.05
1.08
1.02
–
UC60
0.97
0.95
1.00
AHE60D
–
1.03
1.05
0.98
AHR60D
–
1.00
1.00
1.00
AHV60D
–
1.00
1.00
0.96
MV20D
FC/MC60D
1.01
1.01
0.99
MV20D
FC/MC62D
1.02
1.04
1.00
MV20D
FC64D
1.05
1.08
1.00
MX20DN21
FC/MC60D
1.00
0.99
0.96
MX20DN21
FC/MC62D
1.02
1.03
0.95
MX20DN21
FC64D
1.05
1.07
0.95
Furnaces
Coils
T.C.
S.C.
KW
T*(8,L)C*C20
FC/MC/PC60D
0.98
0.96
0.96
T*(8,L)C*C20
FC/MC62D
1.00
1.00
0.98
T*(8,L)C*C20
FC64D
1.04
1.04
0.97
T*(8,L)C*C20
UC60C
0.98
0.96
0.96
T*(8,L)V*C20
FC/MC/PC60D
0.98
0.96
0.96
T*(8,L)V*C20
FC/MC62D
1.00
1.00
0.98
T*(8,L)V*C20
FC64D
1.04
1.04
0.97
T*(8,L)V*C20
UC60C
0.98
0.96
0.96
T*9(C,V)*C20
FC/MC62D
1.00
1.00
1.00
T*9(C,V)*C20
FC64D
1.04
1.04
1.01
T*9(C,V)*D20
FC/MC62D
1.00
1.00
1.00
T*9(C,V)*D20
FC64D
1.04
1.04
0.99
TM8X080C16MP11
FC64D
1.02
1.00
1.00
TM8X100C16MP11
FC64D
1.02
1.00
1.00
TM8X100C20MP11
FC64D
1.03
1.02
0.98
TM8X120C20MP11
FC64D
1.03
1.02
0.98
TM9E100C20MP11
FC64D
1.02
1.00
1.00
TM9E120D20MP11
FC64D
1.02
1.00
1.00
TM9X100C20MP11
FC64D
1.02
1.00
1.00
TM9X120D20MP11
FC64D
1.02
1.00
1.00
TMLX080C16MP11
FC64D
1.02
1.00
1.00
TMLX100C16MP11
FC64D
1.02
1.00
1.00
TMLX100C20MP11
FC64D
1.03
1.02
0.98
TMLX120C20MP11
FC64D
1.03
1.02
0.98
L*(8,L)C*C20
FC/MC/PC60D
0.98
0.96
0.96
L*(8,L)C*C20
FC/MC62D
1.00
1.00
0.98
L*(8,L)C*C20
FC64D
1.04
1.04
0.97
L*(8,L)C*C20
UC60C
0.98
0.96
0.96
L*9C*C20
FC/MC62D
1.00
1.00
1.00
L*9C*C20
FC64D
1.04
1.04
1.01
L*9C*D20
FC/MC62D
1.00
1.00
1.00
L*9C*D20
FC64D
1.04
1.04
0.99
Furnaces
Coils
T.C.
S.C.
KW