ISSUE DATE: FEBRUARY 2018
ORIGINATOR: SKILTEC
REPLACES ISSUE DATE: NOVEMBER 2015
APPROVED BY: S. GONZALEZ
PAGE 15 OF 38
PRODUCT INFORMATION MANUAL
SECTION: 12 LUMINETTE PRIVACY SHEERS
Mount the Installation Brackets — Reveal/Ceiling Fit
If you are mounting on corner or bay windows, refer to “Bracket Locations — Corner and Bay Windows” on
page 11 for specific bracket locations. Return to this page after identifying
the bracket locations.
■
Your order will include the appropriate number of inside/ceiling mount installation brackets. The number
of installation brackets required varies with headrail width, as shown below.
Measure and Mark Bracket Locations
■
Mark 130mm from each jamb on the mounting surface.
➤
If more than two installation brackets are required (see table above), mark the locations of additional
bracket(s) spaced evenly between the two end brackets.
CAUTION:
Installation brackets should be fastened into wood whenever possible. Use drywall anchors
when mounting into drywall. When attaching brackets into drywall, additional brackets may be required to
keep the headrail level after the fabric is attached.
Inside/Ceiling Mount
Installation Bracket
Headrail
Width (mm)
Brackets Required
Up to 1016
2
1017 - 1778
3
1779 - 2438
4
2439 - 3937
6
3938 - 4875
8
Top View
Bracket
Jamb
Jamb
SofTrak
™
Headrail
Space Evenly
Space Evenly
130mm
16mm Gap Required
Motor
130mm