11
0697-101 SafetyBo
x - 10/19
en
4.2 Mount the leakage sensor on the pump
►
Screw the supplied threaded connection piece into the pump
head (
→
Fig. 3, item 1). If there is no thread on the pump
head, the expansion bushing with the slot side must first be
inserted (
→
Fig. 3, item 1a).
►
Connect the leakage sensor and threaded connection to
the hose (scope of delivery
→
Fig. 3, item 2). Use hose clips
supplied for fastening (scope of supply
→
Fig. 3, item 3).
►
The leakage liquid must be collected at the end of the
leakage sensor. Use a hose with an inner diameter of 9 mm.
Fig. 3:
Mount the leakage sensor on the pump
4.3 Completing commissioning
3
Carefully read the operating instructions of motor and pump
tube.
3
Drive of the pump is switched off
►
Connect the SafetyBox to the power supply using the power
supply cable (
→
Fig.4, item 1).
►
There is a socket on the SafetyBox (
→
Fig. 4, item 2) to
switch off the pump drive in the event of leakage. For electric
drives, a motor with low-voltage release is recommended
to prevent uncontrolled restarting. A solenoid valve for
controlling the motor can be connected to the socket of a
compressed air drive.
Fig. 4: 4.3 Completing commissioning