background image

11

0697-101 SafetyBo

x - 10/19

en

4.2 Mount the leakage sensor on the pump

 Screw the supplied threaded connection piece into the pump 

head (

 Fig. 3, item 1). If there is no thread on the pump 

head, the expansion bushing with the slot side must first be 

inserted (

 Fig. 3, item 1a).

 Connect the leakage sensor and threaded connection to 

the hose (scope of delivery 

 Fig. 3, item 2). Use hose clips 

supplied for fastening (scope of supply 

 Fig. 3, item 3).

 The leakage liquid must be collected at the end of the 

leakage sensor. Use a hose with an inner diameter of 9 mm.

 

Fig. 3: 

 

Mount the leakage sensor on the pump

4.3 Completing commissioning

3

 Carefully read the operating instructions of motor and pump 

tube.

3

 Drive of the pump is switched off

 Connect the SafetyBox to the power supply using the power 

supply cable (

 Fig.4, item 1).

 There is a socket on the SafetyBox (

 Fig. 4, item 2) to 

switch off the pump drive in the event of leakage. For electric 

drives, a motor with low-voltage release is recommended 

to prevent uncontrolled restarting. A solenoid valve for 

controlling the motor can be connected to the socket of a 

compressed air drive.

 

Fig. 4: 4.3 Completing commissioning

Содержание SafetyBox

Страница 1: ...Translation of the original instructions Monitoring module SafetyBox Please read this manual before starting up To be retained for future reference en...

Страница 2: ...2 0697 101 SafetyBox 10 19 en...

Страница 3: ...2 Safety 6 2 1 General safety information 6 2 2 Proper use 8 2 3 Identification 9 3 Transport and storage 9 3 1 Transport 9 3 2 Storage 9 4 Starting up 10 4 1 Setting and testing the SafetyBox 10 4 2...

Страница 4: ...product s place of use for future reference Demand the staff to read and observe these instructions and the additional valid documents in particular the safety information and warnings Observe additi...

Страница 5: ...3 Warnings and consequences in case of non compliance Symbol Meaning Safety information Comply with all measures that are marked with a safety sign to prevent injuries or death i Information Recommen...

Страница 6: ...ated applicable documents are complete legible and stored in a place that personnel can access at all times Refrain from any manner of working that endangers personnel or uninvolved third parties In t...

Страница 7: ...n instructed in the safe use of the device and understand the associated hazards Cleaning or user maintenance must not be performed by children Ensure that personnel tasked with work on the device has...

Страница 8: ...following environments on roofed surfaces in open and closed rooms Observe following technical data Voltage 230V Frequency 50 Hz Max switching current 8 A Protection class IP 54 Ambient temperature 1...

Страница 9: ...t and storage 3 1 Transport Unpacking and checking condition of delivery Unpack the SafetyBox on receipt and check for transport damages Report transport damages to the manufacturer immediately Check...

Страница 10: ...1 item 2 Use a screwdriver to set the upper switch to Up Fig 2 Use a screwdriver to set the lower switch to 100 k Fig 2 Connect the SafetyBox to the power supply using the power supply cable Fig 1 ite...

Страница 11: ...he end of the leakage sensor Use a hose with an inner diameter of 9 mm Fig 3 Mount the leakage sensor on the pump 4 3 Completing commissioning 3 Carefully read the operating instructions of motor and...

Страница 12: ...onnection Electric shock can kill you Replacing the fuse may only be carried out by qualified personnel a trained electrician Do not open under voltage The power supply must be interrupted and secured...

Страница 13: ...d only be made by the manufacturer or authorized Lutz dealers Only use Lutz spare parts If other spare parts are used liability on the part of Lutz Pumpen is obsolete 8 Waste disposal Dispose of the d...

Страница 14: ...14 0697 101 SafetyBox 10 19 en...

Страница 15: ...Directives listed Product Monitoring module Type SafetyBox Manufacturer Lutz Pumpen GmbH Erlenstra e 5 7 D 97877 Wertheim Relevant European Directives LVD 2014 35 EU EMV 2014 30 EU RoHS 2011 65 EU 201...

Страница 16: ...umpen GmbH Erlenstra e 5 7 D 97877 Wertheim Tel 49 93 42 8 79 0 Fax 49 93 42 87 94 04 e mail info lutz pumpen de http www lutz pumpen de Subject to technical changes 10 19 Order No 0697 101 Printed in...

Отзывы: