Maintenance
Change the oil
32
© Lutz-Jesco GmbH 2018
BA-10407-02-V08
Motor-driven diaphragm dosing pump
MEMDOS LB
Operating instructions
Maintenance work to be carried
out
Frequency
Clean suction and pressure valves
Regularly
Check that electrical connections
are not damaged
Regularly
Tighten up dosing head bolts
n
Regularly
n
Before initial commissioning
n
After each diaphragm
change
Check diaphragm for leakage due
to rupture
Regularly (as long as no leak
monitoring system is installed)
Check that the installed accesso-
ries are functioning correctly
Regularly
Check the dosing pump for unusual
noises during operation, unusual
temperatures or smells
Regularly
Replace parts that are subject to
wear (diaphragms, valves, seals,
etc.)
When unacceptable levels of
wear are detected
Rinse out and clean the dosing
pump
n
Before changing diaphragms
n
Before taking out of service
for a long period of time
n
After feeding aggressive,
sticky, crystallising or con-
taminated liquids
Checking the electric servomotor
Regularly
Table 26: Maintenance information and maintenance intervals
12.2 Change the oil
Fig. 14: Draining oil on the dosing pump
Precondition for action:
ü
A suitable oil collecting tank is held ready.
@
Gear oil of the viscosity class ISO-VG460 (SAE 140).
Perform the following working steps:
1.
Unscrew the closing screw (1) from the oil outlet (3) and remove the
seal (2).
2.
Let all of the gear oil drain from the housing.
3.
Place the washer seal onto the oil outlet and tighten up the closing
screw.
Fig. 15: Dosing pump oil inlet
4.
Unscrew the closing screw (1) from the oil inlet (2) and remove the
seal (3).
5.
Fill oil in the oil inlet. Check the oil level in the oil level glass (4) at the
same time. The oil level should reach to c. the middle of the oil level
glass.
The following volumes are required:
MEMDOS LB
Filling volumes
4 - 80, 150
0.25 l
110, 160 - 1010
0.75 l
Table 27: Fill levels oil
6.
Place the washer seal onto the oil inlet and tighten up the closing
screw.
ü
Oil change complete.
1
2
3
1
2
3
4