seeTouch
®
guestroom solutions 9
RS232/Ethernet Wiring
WARNING: Shock Hazard.
May result in
death or serious injury.
DO NOT WIRE LIVE!
Interrupt power via circuit breaker before
wiring and servicing.
For Ethernet link, use CAT5 cable (not included) to
connect to auxiliary equipment. Maximum length
for CAT5 cable is 100 m (328 ft). The Ethernet
Link LED will light continuously when the link is
present and will flash when there is link activity.
Additional Ethernet network equipment and cables
not provided.
Network Connections
DIP
Switches
LED 1: Power
LED 2, 3: Unused
LED 4: RS232 Link Tx
LED 5: RS232 Link Rx
LED 6: Data Link Tx
LED 7: Data Link Rx
Data Link
(to control
units,
processors,
and
wallstations)
RS232
Link
Ethernet
Link
Ethernet Interface Wiring
RS232 Link Wiring
• Standard 9-pin serial connector plugs into RS232
equipment, and to Ethernet Interface.
• Must be 15 m (50 ft) or less.
Ethernet Link Wiring
• Standard CAT5 cable connects Ethernet Interface
to PC, router, or other Ethernet source.
• No crossover cable needed.
• Should not exceed 100 m (328 ft).
• Ethernet network and cable not provided.
RS232 Signals
Signals
Pin on 9-pin Cable
Com
5
TxD
3
RxD
2
Содержание seeTouch guestroom solutions
Страница 2: ...2 seeTouch guestroom solutions...
Страница 16: ...seeTouch MCB PELV 230 V 50 60 Hz 8 75 A 40 350 W 24 V 200 mA...
Страница 17: ...seeTouch 3 seeTouch 24 V Lutron QS 3 4 5 6 7 8 9 10 11 12...
Страница 18: ...4 seeTouch 0 40 C 1 8 6 32 63 8 kg 337 22 286 80 8 235 235 191 25 337 74 86 mm PELV PELV...
Страница 19: ...seeTouch PELV 230 50 60 8 75 A 40 350 24 200...
Страница 20: ...seeTouch 3 seeTouch 24 QS Lutron 3 4 5 6 7 8 Ethernet 9 10 11 12...
Страница 21: ...4 seeTouch 0 40 C 1 8 Lutron 6 32 63 8 337 22 286 80 8 235 235 191 25 337 74 86 PELV PELV...