LDE1-96W24V-E Troubleshooting

Problem

Possible Solution

LED does not illuminate •  Verify that the system is wired correctly according to wiring diagram and 

powered.

•  Verify that the LED load is wired correctly; +LED to positive, -LED to 

negative.

•  Verify that the LED load is for “constant-voltage” applications with PWM 

dimming.

•  Verify that the LED load is compatible with the specified voltage output 

of the driver.

•  Lutron drivers are not for use with MR16 LED lamps.

LED does not dim

•  Verify EcoSystem / DALI  control wiring (E1 / DA1 and E2 / DA2) is wired 

according to the instructions for digital control.

LED is flashing, 

flickering, dropping out, 

or has poor dimming 

performance

•  Verify that a compatible control is being used.

•  Verify that the input voltage is within the rated limits.

•  Verify that the LED load is for “constant-voltage” with PWM dimming 

applications.

•  Verify that the length of wires between driver and LED does not exceed 

Lutron specification.

•  Verify that the rated voltage is present at the driver.

•  Certain types of LED loads may be incompatible.* Verify that the LED 

load is within the specified wattage range of 2 W to 96 W.

•  Lutron drivers are not for use with MR16 LED lamps.

LED is flashing slowly 

(6 to 8 second interval)

•  Verify that the LED load does not exceed the maximum specified power 

rating of the driver (96 W).

•  Verify that the LED load matches the specified voltage output of the 

driver.

•  Verify that the length of wire between driver and LED does not exceed 

Lutron specification.

•  Certain types of LED loads may be incompatible.*

LED output appears 

dim at high-end

•  Verify that rated live voltage is present at the terminal.

•  Verify that the driver is operating in an environment within its ambient 

temperature rating.

•  Verify that the driver is not located adjacent to other heat producing 

devices.

•  Verify that the maximum lead length is not exceeded per Lutron 

recommendation.

•  Verify that the LED load is installed per manufacturer’s instructions.

•  Verify that the LED load is compatible with the specified voltage output 

of the driver.

Not all LED strips/

fixtures illuminate

•  Verify that multiple LEDs connected to a single driver are properly wired.

•  Verify that the LED load is installed per manufacturer’s instructions.

Not all LEDs on the 

same strip are evenly lit

•  Verify that the length of wire between the driver and LED does not 

exceed Lutron specifications.

•  Verify that the LED load is for “constant-voltage” with PWM dimming 

applications.

•  Verify that the LED load is installed per manufacturer’s instructions.

LED  is  brighter / hotter 

than expected

•  Verify that the LED load is compatible with the specified voltage output 

of the driver.

*  Certain constant-voltage loads may have added capacitance. Contact the Lutron LED Center of Excellence ([email protected]) for 

more information about these loads.

Need Help?

 Please visit the Hi-lume 1% page at www.lutron.com/europe or  

call the Lutron Customer Assistance at 

+44.(0)20.7680.4481

Hi-lume 1% 

EcoSystem Constant-Voltage LED Driver

 

Compatible Controls

Compatible Controls

•  EcoSystem Controls
•  DALI Controls

 Consult individual component installation for 

more details.

Lutron Electronics Co., Inc.  |  7200 Suter Road  |  Coopersburg, PA  18036-1299

Driver Leads

Maximum wire length between  

LED driver and start of the light engine: 

Wire Gauge

m (ft)

0.75 mm

(18 AWG)

10 (32.8)

1.0 mm

(16 AWG)

15 (49.2)

1.5 mm

2

 (14 AWG)

20 (65.6)

2.5 mm

(12 AWG)

30 (98.4)

4.0 mm

2

* (10 AWG)

50 (164.0)

*  To use wire gauges larger than output strain reliefs’ 

rated gauge of 0.75 mm

2

 to 2.5 mm

2

 (18 AWG to  

12 AWG), connect 30 cm (12 in) or less of rated wire 

from terminal through output strain relief, then connect 

with the larger wire.

EcoSystem Controls

Description

Part Number

Drivers per 

Control

Measured Light 

Output Range

PowPak Dimming Module with 

EcoSystem

RMK-ECO32-DV-B

RMM-ECO32-DV-B

32

100% – 1%

Energi Savr Node with EcoSystem

QSNE-2ECO-D

64 (2 links)

100% – 1%

HomeWorks QS with EcoSystem

LQSE-2ECO-D

64 (2 links)

100% – 1%

GRAFIK Eye QS Control Unit

QSGR-_E

64

100% – 1%

DALI Controls

Description

Part Number

Drivers per 

Control

Measured Light 

Output Range

Energi Savr Node with DALI

QSNE-2DAL-D

64 (2 links)

100% – 1%

GRAFIK Eye QS Wireless with 

DALI

QSGRK-_D

QSGRM-_D

64

100% – 1%

GRAFIK Eye QS with DALI  

(non RF)

QSGR-_D

64

100% – 1%

Quantum Total Light Management 

Hub

QP2-_P_CSE-240

64

100% – 1%

HomeWorks  QS / myRoom  Plus 

Power Module

LQSE-2DAL-D

LQRK-WPM-_D

64 (2 links)

64 

100% – 1%

Содержание Hi-lume EcoSystem

Страница 1: ...r at circuit breaker before installing the unit 1 Remove the top cover to access the terminal blocks and mounting hardware 2 Choose single or multiple driver wiring Open necessary knockouts 3 Install...

Страница 2: ...ucing devices Verify that the maximum lead length is not exceeded per Lutron recommendation Verify that the LED load is installed per manufacturer s instructions Verify that the LED load is compatible...

Страница 3: ...l unit 1 Retirer le couvercle sup rieur pour acc der aux borniers et au mat riel de montage 2 Choisir un c blage pour pilote simple ou multiple Ouvrir les entr es d fon ables 3 Installer le ou les ser...

Страница 4: ...producteurs de chaleur V rifiez que la longueur de c ble maximum ne d passe pas la recommandation de Lutron V rifiez que la charge LED est install e conform ment aux instructions du fabricant V rifiez...

Страница 5: ...ta superior para acceder a los bloques de terminales y la torniller a de montaje 2 Escoja la conexi n a controladores individuales o m ltiples Abra las tapas ciegas necesarias 3 Instale el los agarre...

Страница 6: ...sitivos que generen calor Verifique que no sea excedida la longitud m xima de cable recomendada por Lutron Verifique que la carga de LED est instalada de acuerdo con las instrucciones del fabricante V...

Страница 7: ...die Abdeckung um Zugang zu den Anschlussleisten und zu den Befestigungsteilen zu erhalten 2 Entscheiden Sie sich f r die Verkabelung eines einzelnen oder von mehreren Treibern ffnen Sie die erforderl...

Страница 8: ...in der N he von hitzeproduzierenden Ger ten befindet Sicherstellen dass die Kabell nge nicht die Empfehlungen von Lutron bersteigt Sicherstellen dass die LED Last laut den Anweisungen des Herstellers...

Страница 9: ...ositivo 1 Rimuovere il coperchio superiore per accedere alle morsettiere e alla bulloneria di montaggio 2 Scegliere il cablaggio per uno o pi driver Aprire i necessari fori pretagliati 3 Installare le...

Страница 10: ...assima lunghezza del conduttore non superi il valore raccomandato da Lutron Verificare che il carico LED sia installato secondo le istruzioni del produttore Verificare che il carico LED sia compatibil...

Отзывы: