Module and MI Mounting (continued)
Module
Control Wiring:
HWI-MI-120
Control Wiring:
Module Control Wiring:
Plug the second 4-pin connector of the control harness (the first 4-pin connector says “TVM ISO” and is not used)
into the modules as shown. Start with the top right module working your way down to the lower left module, then
to the lower right. Repeat this for up to 8 modules. Set the rotary switch on each module according to the
corresponding HomeWorks
R
software.
HWI-MI-120
Power Wiring:
®
®
Installation Guide for CGP2730 Dimming and Switching Subplate 7
HWI-MI-120 Control Wiring:
Plug the 4-pin connector from the control harness to the receiving 4-pin connector in the top right spot on the
HWI-MI-120 as shown below. Make sure the wires are not pinched and are not in a location that can be
damaged once the cover is installed.
HWI-MI-120 Power Wiring:
Plug the large, 2-pin connector from the control terminal blocks into the receiving 2-pin connector wired to
the HWI-MI-120. Ensure power wire to the MI is maintained with a minimum of .25 in (6 mm) from
communication wires. Dress the wires such that they will not be damaged by the components within the panel.
6 – 4 AWG
0 AWG
1
–
4
1
8 AWG or (2)
14 – 10 AWG
2,5 – 4
2
mm
6
1
–
0
1
2
mm
6
2,5 – 4
2
mm
2
mm
or (2)
3/8 in
10 mm
10 mm
10 mm
3/8 in
3/8 in
20 in-lb
20 in-lb
3
,
2 N
•
m
2,8 N
•
m
4 N
•
m
25 in-lb
35 in-lb
6 – 4 AWG
0 AWG
1
–
4
1
8 AWG or (2)
14 – 10 AWG
2,5 – 4
2
mm
6
1
–
0
1
2
mm
6
2,5 – 4
2
mm
2
mm
or (2)
3/8 in
10 mm
10 mm
10 mm
3/8 in
3/8 in
20 in-lb
20 in-lb
3
,
2 N
•
m
2,8 N
•
m
4 N
•
m
25 in-lb
35 in-lb
18 - 10 AWG
0,75 - 6,0 mm2
8 mm
5/16 in
0,6 - 0,8 N
•
m
5,3 - 7,1 in-lbs
75 °C
Cu Al
N
N
H
H1
SH1
H2
SH2
H3
N
Power Relay Module
120 V
~
50 / 60 Hz
HW-RPM-4R
N
H
DH1
DH2
DH3
DH4
H
N
Dimming Module
120 V
~
50 / 60 Hz
HW-RPM-4U-120
HW-RPM-4J-120
HW-RPM-4FSQ-1
20
SH3
H4
SH5
N
R1
L1
R2
L2
R3
N
Quiet Fan
Speed
Control Module
120 V
~
50 / 60 Hz
HW-RPM-4M-120
L3
R4
L4
H
H
WARNING | ADVERTE
NCIA |
AVERTISSEMENT
| ACHTUN
G
Gefahr Eines Ele
ktrischen Schlage
s
Unter Umstän
den müssen
Sie mehr als
einen
Schalter strom
los schalten, b
evor Sie
Wartungsarbei
ten ausführen
können. Vor d
em
Au
flegen der Kab
el, schalten S
ie bitte alle
Sicherungsaut
omaten und Hau
ptschalter aus
und sichern
diese in der AU
S-Position.
Risque D'électro
cution
- Peut causer
le décès
de la personne
ou de graves
lésions. Plus d
’un
débranchement
peut être requ
is afin de procede
r
á la desconne
ction totale de l
’unité. Débran
cher
toutes le sourc
es d’énergie
avant de proc
éder à
l’entretien de c
ette unité. Ne p
as utiliser
l’équipement s
ans cet écran
en place.
Risk Of Electric
Shock
- May result in
serious
injury or death.
More than on
e disconnect m
ay be
required to
de-energize th
is device. Disc
onnect all
power sources befor
e servicing un
it.
Riesgo De
Choque Eléctri
co -
Puede resulta
r en lesiones
graves o
la muerte.
Puede necesita
rse más de una
desconexión p
ara
desenergizar e
ste dispositivo
. Desconecte t
odas
las fuentes d
e alimentación
antes de pres
tar
servicio a la unidad.