![Lutron Electronics AuroRa AR-ENT-2S3D Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/lutron-electronics/aurora-ar-ent-2s3d-series/aurora-ar-ent-2s3d-series_package-installation-manual_1951053010.webp)
1
2
3
4
Lutron
|
10
Need help? Contact Lutron Technical Support 24/7: 800.523.9466
lights controlled by two switches
OR
Designer
Traditional
Remove wallplate
Turn power off at circuit
breaker or remove fuse
Uninstall switch
1
2
3
✓
Helpful Hint:
Save your wallplate and screws.
A.
Tag the wire attached to
the different colored screw.
This screw is usually labeled
COMMON.
B.
Disconnect the wires from
the switch.
To pull out wires 1, 2, and 3, refer
to page 8 step 4B for instructions.
2
4 (ground wire)
1
4 (ground wire)
3
NOTE:
You only need to replace one of the two switches controlling the light
with an AuroRa
®
dimmer/switch.
Unscrew existing switch and
pull it forward out of the wall
(do not disconnect wires yet)
B.
Three insulated
wires inserted
into back of existing switch
.
One ground wire attached to
a screw.
To uninstall switch, refer to
step 4 Figure 4B.
A.
Three insulated wires
each
attached to a screw
. One
ground wire (green or bare)
attached to a screw.
To uninstall switch, refer to
step 4 Figure 4A.
Once switch is pulled out, you should see one of the following:
Neutral
NOTE:
If intending to install an
AuroRa
switch in this location, ensure
neutral is available before
disconnecting/uninstalling switch.
Figure 4B
Figure 4A
✓
Helpful Hint:
For wiring diagram for lights
controlled by two switches see
step 3B on page 21.
To avoid fire, shock or
death,
turn power off
at corresponding circuit
breaker or remove fuse.
WARNING