background image

 
 

 

 

  

 

LT-300 SD and LT-300 HD 
Digital Video Colposcope  

Operator’s Manual 

Lutech Industries, Inc.

 

Version 5.2 – 210423 

 

Содержание LT-300 HD

Страница 1: ...LT 300 SD and LT 300 HD Digital Video Colposcope Operator s Manual Lutech Industries Inc Version 5 2 210423...

Страница 2: ...g 12 1 6 Additional Information 12 Chapter 2 Camera and Stand Assembly 13 2 1 Camera Composition 13 2 2 What s included with the Colposcope 13 2 3 Pre Assembly Check List 14 2 3 1 Vertical Stand Parts...

Страница 3: ...the Software 42 6 2 3 Installing the Software 42 6 3 Operation 44 6 3 1 Main Screen 44 6 3 2 Session Window 46 6 3 3 Foot Pedal 46 6 3 4 Full Screen Mode 47 6 3 5 Picture Review 47 6 3 6 Video Review...

Страница 4: ...7 5 Transportation 55 7 6 Device Disposal 55 Chapter 8 Troubleshooting 56 8 1 Troubleshooting 56 Appendix A Specification 58 I Power Supply Adapter 58 II Battery 58 III Grounding 58 IV Environmental S...

Страница 5: ...oes not come into contact with patient Electrical Class Class I Class I 2 Manufacturer Lutech Industries Inc 105 Remington Blvd Suite C Ronkonkoma NY 11779 U S A T 631 676 7432 F 631 619 0723 www lute...

Страница 6: ...s responsibility to return the colposcope to the Repair Center This warranty does not cover breakage or failure due to improper use modification neglect accidents or shipping damage In Addition this...

Страница 7: ...e if available Alternatively you can visit www lutechmedical com and fill out a service request form to obtain an RMA number Warranty is not covered if The colposcope frame has been opened or tampered...

Страница 8: ...connected to The LT 300 SD and LT 300 HD digital video colposcopes Always turn the colposcope off first before plugging in or unplugging the video cable Never stare at the lights around the lens At a...

Страница 9: ...ave any solvent residue on the device If residue is present wipe it off quickly with a cloth damp with distilled water Then pat dry with a dry cloth The outer shell of the colposcope may not be opened...

Страница 10: ...the software that works best for them as well as complies with all regulatory requirements within their territory The LT 300 SD and LT 300 HD may also be integrated into telemedicine and hospital EMR...

Страница 11: ...ced color image module circular LED group light source and control circuit all integrate into one handheld camera The LT 300 HD digital video colposcope displays crystal clear imaging in high definiti...

Страница 12: ...s used to support the camera and connect with the video cable Vertical Stand Specifications Measurement of the vertical stand is taken with the camera base mount on and the colposcope off LT 300 SD LT...

Страница 13: ...e to exposure to humidity and temperature difference Please ensure that there is no water condensing in the device before use Operating rooms should be ventilated and protected from static discharge n...

Страница 14: ...cess 2 1 Camera Composition The LT 300 SD and LT 300 HD digital video colposcopes includes a camera circular LED group light source control circuit enclosure and remote Diagram 2 1 1 2 2 What s includ...

Страница 15: ...cement cables or other accessories please contact your distributor or Lutech representative 2 3 Pre Assembly Check List Ensure all parts are present before assembly 2 3 1 Vertical Stand Parts List The...

Страница 16: ...main cable or the power box is not already assembled please see section 2 6 Troubleshooting Diagram 2 4 1 2 Place the Wheel Base in front of you with the longer legs toward you Diagram 2 4 2 3 Insert...

Страница 17: ...tom of the power box Diagram 2 4 6 NOTE There is a bump on top of the red dot on the main cable connector This bump will fit into the notch located on the power box connector Make sure to match the bu...

Страница 18: ...head Diagram 2 4 9 9 Turn the camera base plate over and pull out the ring on the other side Place the camera base plate screw over the hole under the colposcope camera Turn the ring clockwise to atta...

Страница 19: ...ymore Pull the knob outward to allow it to continue turning Continue turning counterclockwise until it stops The base mount is now fully open and is ready to receive the Camera which is attached to th...

Страница 20: ...plate release knob clockwise to secure the colposcope Diagram 2 4 13 CAUTION Do not let go of the colposcope camera without ensuring that the base plate release knob is tightened correctly and the cam...

Страница 21: ...the remote cable connector These bars will fit into the grooves on the connector located on the bottom of the colposcope handle Make sure to match the bars to the grooves The cable will plug in easil...

Страница 22: ...not attached please see section 2 6 Troubleshooting Diagram 2 5 1 2 Attach the Lower Stand to the Base using 4 x M8 25 screws Diagram 2 5 2 3 Take out the swing arm and inspect it The swing arm shoul...

Страница 23: ...This bump will fit into the notch located on the power box connector Make sure to match the bump to the notch The cable will plug in easily Do not force it in Diagram 2 5 6 6 The Camera Base Plate sho...

Страница 24: ...head Diagram 2 5 8 8 Turn the camera base plate over and pull out the ring on the other side Place the camera base plate screw over the hole under the colposcope camera Turn the ring clockwise to atta...

Страница 25: ...nob outward to allow it to continue turning Continue turning counterclockwise until it stops The base mount is now fully open and is ready to receive the Camera which is attached to the camera base pl...

Страница 26: ...easily 12 Slide the camera base plate onto the camera mount and tighten the base plate release knob clockwise to secure the colposcope Diagram 2 5 12 CAUTION Do not let go of the colposcope camera wi...

Страница 27: ...he user may wish to change the default tension set for the swing arm The swing arm is adjusted to swing and move easily but with enough tension on it so as not to swing wildly To adjust the tension of...

Страница 28: ...to the hole Connectors on both ends are identical Diagram 2 6 1 1 2 The power box is not attached to the vertical tube There should be 2 power box assembly rings and 4 screws Each ring is a semi circl...

Страница 29: ...ng arm assembly Using your fingers gently pinch the black cable enclosures located on the swing arm portion of the swing arm assembly and pull downward Make sure to pinch where the yellow arrow indica...

Страница 30: ...n the vertical stand Diagram 2 6 2 6 Use the screws provided to join the semi circles and attach the power box to the vertical tube Diagram 2 6 2 7 2 7 Tips and Suggestions The vertical stand is desig...

Страница 31: ...cal stand This allows the adjustment of the wheel base without restraint from other parts of the device Tip 2 Consider the location of peripheral devices It is recommended that the user consider the l...

Страница 32: ...s right the head of the colposcope can be moved freely and will stay in position after the movement is complete and the user has let go of the camera without having to tighten any knobs Diagram 3 1 1...

Страница 33: ...tension on it so as not to swing wildly To adjust the tension of the swing arm use a M3 M6 hexagonal wrench on the following sections of the swing arm Diagram 3 3 2 1 This area can be adjusted by the...

Страница 34: ...s not enough to stop the vertical stand completely 3 5 Remote Hanger The user may request an extra long remote cord To assist with cord management the remote has a notch built into the back side Turn...

Страница 35: ...s by providing the LT 300 SD and LT 300 HD colposcope as an accessory for their telemedicine units If you have a telemedicine infrastructure in place you may be able to obtain the LT 300 HD as an add...

Страница 36: ...and the power box off or you may damage the camera or power box components 4 2 Computer Setup If you would like to save pictures or videos and create reports then the colposcope must be connected to...

Страница 37: ...USB connector from the foot pedal to the computer 5 Connect the colposcope s power adapter to the power box and then plug the power adapter into a wall socket 6 Turn the colposcope on by pressing the...

Страница 38: ...e LT 300 HD colposcope Please contact your hospital engineer or telemedicine provider for details The colposcope will work with most software that allows video input and attachment of files A EMR syst...

Страница 39: ...y Check List Before using the colposcope check the following to ensure safe operation Make sure there is no mechanical damage Inspect all the cables parts and accessories and make certain they have al...

Страница 40: ...the center or peripherals of the image 5 Freeze Freezes the live feed image on the screen Press again to unfreeze the image 6 Preset Saves a green filter level for quick access Short press Go to the...

Страница 41: ...focus and adjust brightness and color filters The zoom function is accompanied by auto focus As you zoom the camera will adjust its focus automatically for clarity If your image is not focusing after...

Страница 42: ...r own discretion Other viewers or media software will work to capture pictures and videos from the Lutech colposcopes If the intention is to find a software to use with the Lutech colposcope please co...

Страница 43: ...er on the USB drive that came with the colposcope If you did not get this USB drive you may request a download link from your Lutech representative Please contact Lutech by phone or email during opera...

Страница 44: ...is now complete Check the box next to Launch LutechViewer if you would like to start the software when you click on the Finish button Otherwise click the Finish button to complete installation and ex...

Страница 45: ...eference No field Using these symbols will open an error message The reference number will be used in the name of the automatically generate folder where all pictures and videos from this session will...

Страница 46: ...any other type of video card available to the computer NOTE Please refer to Section 3 8 1 Video Source Troubleshooting for assistance Foot Pedal V 1 Select this box if the Lutech foot pedal you receiv...

Страница 47: ...this button to start recording what s in the live video area The red circle icon within the button will change to a gray square Press the gray square button to stop recording NOTE The video stops reco...

Страница 48: ...on located at the bottom left corner of the Session Window to enter Full Screen Mode Pictures and Videos can be taken during Full Screen Mode using the foot pedal The upper left corner displays confir...

Страница 49: ...ftware out before you have a live session Start the software and enter all the information required Take some pictures as well as videos using the buttons on the Lutech Viewer software as well as the...

Страница 50: ...m Solution Part of the software is displayed off screen Please make sure the resolution for your computer is set to 1920 1080 Additionally please make sure your display setting for scale and layout is...

Страница 51: ...t Lutech We will be happy to assist you 6 5 Folder Naming Structure When the user clicks on the Start Session button a folder is created using the Reference No and the current Date and Time in the loc...

Страница 52: ...ay format within the folder file name In this case it would show up as 2020 01 28 or 20200128 Time 14 30 26 This is 2 30pm and 26 seconds in 24 hour format The time portion will be expressed as hour m...

Страница 53: ...k the cloth in liquid and use it to wipe the colposcope Only dampen the cloth to avoid too much liquid from getting onto the colposcope Do not pour liquid on the colposcope and do not submerge Do not...

Страница 54: ...he lens cloth or tissue and wipe in a gentle circular motion 6 If the smudges are still there moisten the lens cloth with some lens cleaner Then wipe in a circular motion from center outward to the si...

Страница 55: ...placement Battery Life Span 1000 charges or 5 years Work Duration 4 5 hours Time for Full Charge 3 5 hours Charging Method Automatic As long as the colposcope is plugged into a working wall socket the...

Страница 56: ...ck the colposcope in place to prevent movement of any kind Do not rely solely on the caster locks WARNING The caster locks on the wheel base are not enough to keep the colposcope from moving during tr...

Страница 57: ...utech s service center The camera may be damaged Please contact Lutech s service center The image cannot be captured or a black screen is displayed The cable may not be connected properly Check the co...

Страница 58: ...the casters are down If it is lift up to disengage the lock All 4 casters have locks so make sure all 4 are disengaged For any questions or concerns please contact the manufacturer or authorized repai...

Страница 59: ...tor light is off Output 7 4V 2200mAh Model Number 18650 2S Type Li ion III Grounding Ensure the equipment is grounded properly by plugging it into an AC receptacle with ground included Speak to the re...

Страница 60: ...500 K 5000 5500 K White Balance Auto Adjustable Auto Adjustable Illuminance Max 3000 lx Max 3000 lx UV Filter Default No Optional Yes Focusing Distance Setup Yes Yes Timer Yes Yes Battery Power 4 5 ho...

Страница 61: ...LT 300 SD Camera on Vertical Stand Fully Contracted 13 5 x 13 5 x 35 in 34 3 x 34 3 x 88 9 cm 26 lb 11 8 kg Fully Extended 13 5 x 13 5 x 46 in 34 3 x 34 3 x 116 8 cm LT 300 HD Camera on Vertical Stand...

Отзывы: