© PROPERTY OF LUNDIX IT SWEDEN, ALL RIGHTS RESERVED – THE DISCLOSURE OR OTHER COMMUNICATION, COPYING, REPRODUCTION AND ANY USE WHATSOEVER IS FORBIDDEN WITHOUT THE WRITTEN AUTHORIZATION
OF LUNDIX IT.
SPC SmartBox User Manual
Revision
1.1
Page
35 of 62
Reference
2017-110
System (Automation Mode)
changes to,
changes from
Home, Away, Night, Vacation
System (Global variable)
falling edge less than,
falling edge greater than,
changes to,
changes from
Threshold value
Time (System Time)
time is
HH:MM:SS
Time (Sunrise)
time is (s offset)
Offset -360 to 360 minutes
Time (Sunset)
time is ( offset)
Offset -360 to 360 minutes
Select trigger
Manual
if you only want to run the scene manually from the
Run
button in the Scene
List. It is not possible to define conditions for a Manual scene.
5.1.6
Scene Conditions
Condition Type
Condition Operator
Condition Value/Parameter
Actuator
equal
Off, On
Alarm Area (mode)
equal,
not equal
Unset, Partset A, Partset B, Fullset
Alarm Area (confirmed, alarm,
tamper, trouble)
equal,
not equal
No Confirmed Alarm, Confirmed Alarm
No Alarm, Alarm
No Tamper, Tamper
No Trouble, Trouble
The trigger will have Confirmed Alarm, Alarm,
Tamper and/or Trouble status if at least one
zone in the area has corresponding status.
Alarm Zone (input)
equal,
not equal
Open, Closed, Short, Disconnected, PIR Masked,
DC Substitution, Sensor Missing, Offline
Alarm Zone (status)
equal,
not equal
OK, Inhibit, Isolate, Soak, Tamper, Alarm,
Trouble
Battery, Meter and Sensor
less or equal than,
greater than
Threshold value
KNX (DPT1)
equal
0, 1
KNX (DPT2)
priority disabled and value equal,
priority enabled and value equal
0, 1
KNX (DPT3, DPT5, DPT9, DPT12,
DPT13, DPT14)
less or equal than,
greater than
Threshold value
KNX (DPT18)
scene equal,
scene not equal
1 – 64 (scene number)
System (Automation Mode)
equal,
not equal
Home, Away, Night, Vacation
System (Global variable)
less or equal than,
greater than,
equal,
not equal
Threshold value
Time (System Time)
time after,
time before
HH:MM:SS
Time (Sunrise)
time after (s offset),
time before (s offset)
Offset -360 to 360 minutes
Time (Sunset)
time after ( offset),
time before ( offset)
Offset -360 to 360 minutes
NOTE! Maximum trigger and condition time based on Sunset and offset is midnight. Minimum
trigger and condition time based on Sunrise and offset is midnight.