background image

LF2020-INS-LAB-RevG18 

4

2  SAFETY PRECAUTIONS

  IMPORTANT: Before using patient lift, read and adhere to the following safety precautions 

and warnings. Failure to do so could result in serious personal injury or damage to your 

patient lift.

Always consult your healthcare professional to determine safe methods most suitable for 
your individual abilities. Protect yourself, your attendant and patient lift by having it serviced 
regularly. If you experience any malfunction, contact GF Tech Support at 1.770.368.4700 or your GF 
authorized distributor immediately, as a hazardous condition could result, causing personal injury 
or damage to your patient lift.
Periodic inspection, adjustment and replacement of worn parts are necessary to provide years of 
excellent service. Refer to 

CARE AND MAINTENANCE

 section of this manual.

Maintenance MUST be performed by qualified personnel ONLY.

Significance of safety statements

Note the following special statements, used throughout this manual, and their significance:

  WARNING: Indicates a potential hazard situation or unsafe practice that, if not avoided, 

could result in death or serious personal injury.

  CAUTION: Indicates a potential hazard situation or unsafe practice that, if not avoided, 

could result in minor or moderate personal injury.

s

  NOTICE: Indicates a potential hazard situation or unsafe practice that, if not avoided, could 

result in product or property damage.

Info: Provides application recommendations or other useful information to ensure that you get 

the most from your product.

WARNINGS

  WARNING: Important! Read and understand these instructions before assembling or using 

the Lumex LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS. If you do not understand 

any part of these warnings, cautions or instructions, contact a healthcare professional for 

direction in the use of this product. If the Lumex LF2020 Easy Lift STS / LF2090 Bariatric 

Easy Lift STS is not properly assembled, personal injury and damage to the LF2020 / 

LF2090 could result.

  WARNING: If components are damaged or missing, contact your GF authorized distributor 

immediately. DO NOT use substitute parts. Use only Lumex replacement parts. The use of 

non-Lumex replacement parts could cause personal injury, property damage, and void the 

warranty.

  WARNING: Unauthorized modification of your patient lift could cause personal injury, 

property damage, and void the warranty.

 WARNING: The maximum weight capacity of this device is:

    LF2020 Easy Lift STS: 400 lb, EVENLY DISTRIBUTED 

  LF2090 Bariatric Easy Lift STS: 600 lb, EVENLY DISTRIBUTED

  DO NOT exceed the maximum weight capacity.

  WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury 

caused by improper assembly or use of this product.

Содержание LF2020 Easy Lift STS

Страница 1: ...LF2020 INS LAB RevG18 Read this manual before operating your Easy Lift Sit to Stand Save this manual for future use LF2020 EASY LIFT SIT TO STAND LF2090 BARIATRIC EASY LIFT SIT TO STAND USER MANUAL...

Страница 2: ...TRANSPORTATION INSTRUCTIONS 7 5 ASSEMBLY INSTRUCTIONS 8 CHARGING THE BATTERIES 9 CHECKING BATTERY CAPACITY 9 ALARM BUZZERS 9 6 OPERATING INSTRUCTIONS 10 LIFTING THE PATIENT 11 7 CARE AND MAINTENANCE 1...

Страница 3: ...est that the operator try all the various lifting slings and equipment until the operator is confident with how the patient lift operates The lifting procedures should be explained to the patient befo...

Страница 4: ...te personal injury s NOTICE Indicates a potential hazard situation or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other...

Страница 5: ...s in the sling WARNING Do not attempt to maneuver the lift by pushing on the mast boom actuator or patient Always maneuver the lift with the handle WARNING During lifting or lowering whenever possible...

Страница 6: ...FEATURES EASY LIFT SIT TO STAND FEATURES Pendant Actuator Lifting Boom Knee Pad Footrest Base Brake Mast Control Box CONTROL BOX FEATURES RESET Button Battery Testing Battery Charger Plug In Actuator...

Страница 7: ...s contents If damage is evident notify the carrier or your GF authorized distributor 2 Remove all loose packing from the carton 3 Carefully remove all the components from the carton Info Unless the pa...

Страница 8: ...4 Attach boom to mast and hand tighten bolt and nut 5 Attach the L shaped arms to the back of the knee pad 6 Attach knee pad assembly to the mast 7 Place the control box in the bracket 8 Insert the ac...

Страница 9: ...e control box Frequent plugging and unplugging of the pendant and actuator to and from the control box may damage the control box CHECKING BATTERY CAPACITY Info To check remaining battery capacity pre...

Страница 10: ...ither open or closed position Preparation before lifting 1 Turn on the power by turning the RED RESET BUTTON clockwise 2 Press the pendant UP or DOWN button once 3 After the battery indicator lights d...

Страница 11: ...raps to the hooks 5 Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest 6 Press the UP button on the hand pendant 7 Before...

Страница 12: ...ave them hold their arms around the chest 6 Press the UP button on the hand control 7 Before the patient s body is lifted from the chair stop and make sure the sling is secured and patient s knees are...

Страница 13: ...0 368 4700 for further information When you believe a component or part is not functioning properly immediately contact GF Tech Support at 1 770 368 4700 as a potentially hazardous condition could exi...

Страница 14: ...ting properly x x x Inspect all base hardware for wear x Mast Ensure that mast is fully engaged and locked into mast sleeve x x Inspect mast for bends or deflections x Inspect all mast hardware for we...

Страница 15: ...operate even though battery indicator shows charge Battery charger still plugged in Poor connection between control box and pendant or defective pendant Poor connection between actuator and control bo...

Страница 16: ...gth 50 Lifting height range Info As measured from sling hooks Minimum 27 Maximum 71 Range 35 Mast height 50 Maximum weight capacity LF2020 Easy Lift STS 400 lb EVENLY DISTRIBUTED LF2090 Bariatric Easy...

Страница 17: ...NING WARRANTY SERVICE This limited warranty shall only apply to defects that are reported to the Distributor from whom the Customer purchased the product within the applicable warranty period If there...

Страница 18: ...LOYEE OR INDEPENDENT CONTRACTOR WAGES PAYMENTS AND BENEFITS The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and super...

Страница 19: ...spection 7 Intended use 3 Intended use contraindication 3 Introduction 3 L Lift and transfer from bed 11 Lift and transfer from chair 12 Lifting the patient 11 Lubrication 13 M Maintenance schedule 14...

Страница 20: ...can be found on our website www grahamfield com 2005 GF Health Products Inc All Rights Reserved Graham Field and Lumex are trademarks of GF Health Products Inc One Graham Field Way Atlanta GA 30340 31...

Отзывы: