Annex 4 - Lw11059 and Lm11059
snapshot timing diagram
Signals are active on rising edge.
Trigger to start exposure
33.874us
Trigger to start strobe
34.272us
Strobe duration
0-10ms
SOF(start of readout) and
end of exposure
221.472us
Trigger - End of readout
200ms
Minimum exposure
187.598us