N32O
User's manual
48
4001
0, 1
0
Type of operation used for the measured value on the main input
Value
Type of operation
0
Dividing by a constant.
1
Multiplication by a constant.
4002
0…65535
0
Minimum duration of a low level on the main input before it is
considered as the low level. Value in microseconds or milliseconds
(see Section 5.3.2 and 5.4.1).
4003
0…65535
0
Minimum duration of a high level on the main input before it is
considered as the high level. Value in microseconds or milliseconds
(see Section 5.3.2 and 5.4.1).
4004
0, 1
1
Permission to control the main input using the meter keypad.
Value
Description
0
No control using the keypad.
1
Disabled control using the keypad.
4005
0...5
0
Mathematical functions used for the measuring value on the main
input.
Value
Description
0
Disabled.
1
Square of the measuring quantity.
2
Square root of the measuring quantity.
3
Reciprocal of the measuring quantity.
4
Square of the reciprocal of the measuring quantity.
5
Square root of the reciprocal of the measuring quantity.
4006
1...600
10
Single measurement time on the main input – gating time. The value is
the multiplicity of 100 ms period (SAVG parameter)
4007
1...3600
1
Number of single measurements averaged using the moving window
method (main input).
4008
0...2
Defines the period for pulse speed conversion in
CNTFL
measurement
mode.
Value
Description
0
Pulse speed expressed as the number of pulses per
second.
1
Pulse speed expressed as the number of pulses per minute.
2
Pulse speed expressed as the number of pulses per hour.
4009
0…5
1
Type of measuring signal at the additional input
0
Bidirectional counter of fast changing signals.
1
Bidirectional counter of slow changing signals.
2
Period measurement.
3
Frequency measurement.
4
Rotation speed measurement.
5
Working time counter.
6
Timer
4010
0, 1
0
Type of operation used for the measured value on the additional input
Value
Type of operation
0
Dividing by a constant.
1
Multiplication by a constant.
4011
0...65535
0
Minimum duration of a low level on the additional input before it is