15
510 Series Analog PTZ Camera
Protocol Status
If you don’t want to use auto-match, this allows you to select your
preferred protocol.
Protocol
Choose Pelco-P, Pelco-D, HIKvision, Kalatel, Vicon, or auto-
match.
485check
Turn this on if you want to check RS-485 diagnostic messages for
your camera.
Setting this to auto still allows you to check messages, but disables
the setting once no errors are detected.
Power Memory
This is how long the camera remembers its status from before a
power loss. If there is a lack of power longer than the memory
time, the camera restarts its PTZ patrolling from its defaults.
Near Focus Level
This allows you to prevent the camera from focusing on objects
that are too close. Experiment to see which level works best for
you.
Coaxitron Active
Enable this to transmit the RS-485 signal along with the video
signal through the BNC cable. If the connected DVR also supports
coaxial transmission, the RS-485 cable is unnecessary.
Set the protocol using the item below. Ensure the protocol and
baud on the camera and DVR match.