Model 2241-3 & 3i
Technical Manual
Section 1
Ludlum Measurements, Inc.
Page 1-1
January 2016
Introduction
he Model 2241-3 is a portable microprocessor-based digital Scaler/
Ratemeter designed for use with scintillation, Geiger-Mueller (GM),
and proportional-type detectors for measurement of ionizing
radiation. Data is presented on a four-digit (six digits in the scaler
mode) Liquid Crystal Display (LCD) with moving decimal point. A toggle
switch labeled
SCA
/
RATE
selects the desired operating mode for the
instrument. A five-position switch labeled
˝
OFF
/
DET
1/
DET
2/
DET
3/
DET
4
˝
allows for a quick change of operating parameters when changing out
detectors.
Programmable display units (
RATEMETER
mode only) can be represented in
R/hr, Sv/h, cpm, or cps with multipliers of micro (µ) or milli (m) for R/hr
and Sv/h and kilo (k) for cpm or cps. The display units are auto-ranging,
enabling the readout to display a broad range of radiation levels. The display
also offers lower limit capability. For example, the display can be set to show
only values that are greater than or equal to1 µR/hr.
This instrument incorporates independent adjustable alarms for
RATEMETER
and
SCALER
operating modes. The
RATEMETER
mode has two alarm
indicators. The first-level alarm is indicated by display of the word
˝
ALERT
˝
on the LCD. The second-level alarm is indicated by display of the word
˝
ALARM
˝
and by the emitting of a continuous audible tone. The
SCALER
alarm condition will also display the word
˝
ALARM
˝
and produce the same
audible tone. Both audible alarms may be silenced (acknowledged) by
depressing the
RESET
switch. All alarms are concurrent.
Other features include: 1) Dead Time Correction (DTC) to compensate for
detector dead time; 2) audible click-per-event with programmable 1, 10, 100,
and 1000 divide-by; 3) LCD backlight with programmable
ON
time; 4)
programmable fixed or variable response time; and 5) count overflow visual
alarm, indicative of the counting circuitry nearing the maximum counting
capability.
Section
1
T
Содержание 2241-3
Страница 4: ......
Страница 5: ......
Страница 48: ...Model2241 3 3i TechnicalManual Section8 Ludlum Measurements Inc Page 8 19 January 2016 ...
Страница 49: ...Model2241 3 3i TechnicalManual Section8 Ludlum Measurements Inc Page 8 20 January 2016 ...
Страница 50: ...Model2241 3 3i TechnicalManual Section8 Ludlum Measurements Inc Page 8 21 January 2016 ...
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......
Страница 72: ......