CONFIGURATION
70
4.21. Expansion Port Configuration
The expansion port configuration can be called up by airbrush option External Port
in menu. Inside the window can be defined Baudrate, number of Data bits, Parity, number
of Stop bits, Protocol and Mode. Split timeout is for messages.
In mode TCP server it is necessary to enter the TCP port, on which the router will
listen to incoming requests about TCP connection. In mode TCP client it is necessary to
enter the Server address and final TCP port.
At Check TCP connection it activates verification of coupled TCP connection. Inside
the window can be define time, after which it will carry out verification of the connection
(Keepalive Time), waiting time on answer (Keepalive Interval) and number of tests
(Keepalive Probes).
The changes in settings will apply after pressing the Apply button.
In case of M-BUS expansion board installed and when chosen protocol is not M-BUS
or M-BUS TCP then sent data will be returned back to the device! If e.g. LINE protocol is set-
up on this port, then data will return back to the source.
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de