background image

 

DESCRIPTION 

20 

 

2.8.4.5. 

Expansion port CNT 

Pin 

number 

Signal mark 

Description 

Data flow direction 

BIN1/CNT1

 

Binary input/counter input

 

Input

 

BIN2/CNT2

 

Binary input/counter input

 

Input

 

BIN3

 

Binary input

 

Input

 

BIN4

 

Binary input 

 

Input

 

GND

 

Signal ground

 

 

OUT1

 

Binary output (open collector)

 

Output

 

AN1

 

Analogue input

 

Input

 

AN2

 

Analogue input

 

Input

 

The  user  interface  CNT  is  for  monitoring  and  processing  of  analogue  and  binary 

signals and to control (settings) of binary signals. Available are 2 counter and 2 binary inputs 
or 4 binary inputs, 2 analogue inputs and 1 binary output. The setting of binaries and counter 
inputs by the help of firmware in which the single inputs and output is defined. Binary output 
is off in default configuration(it is not switched to ground).

 

 

Typical connection of a router measuring circuits: 

 

The  router  does  not  support  to  modify  any  signals  of  the  CNT  port,  for  example  logical 
functions. 

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de 

Содержание ER 75i

Страница 1: ...EDGE router ER 75i ER 75i DUO ER 75i SL and ER 75i DUO SL USER S GUIDE LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 2: ...fication of optional PORT1 21 2 10 Modem status indication 24 2 11 Putting into operation 24 2 12 Mechanical external dimensions and mounting recommendations 25 3 Expansion port mounting 28 3 1 Expansion port mounting for ER 75i and ER 75i DUO router 28 3 2 Expansion port mounting for ER 75i SL and ER 75i DUO SL router 30 4 Configuration setting over web browser 32 4 1 Network Status 33 4 2 DHCP S...

Страница 3: ... NAT Configuration 82 4 35 6 OpenVPN Tunnel Configuration 82 4 35 7 Ipsec Tunnel Configuration 84 4 35 8 GRE Tunnel Configuration 85 4 35 9 L2TP Configuration 85 4 35 10 DynDNS Configuration 86 4 35 11 NTP Configuration 86 4 35 12 SNMP Configuration 86 4 35 13 SMTP Configuration 87 4 35 14 SMS Configuration 87 4 35 15 Expansion Port Configuration 88 4 35 16 Startup Script 88 4 35 17 Up Down Script...

Страница 4: ... Information notice information which contains useful advice or special interest GPL license Source codes under GPL license are available free of charge by sending email to info conel cz Conel s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Issue in CZ 5 16 2011 Declared quality system ISO 9001 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 5: ...ot be exceeded Do not expose the communication module to extreme ambient conditions Protect the communication module against dust moisture and high temperature It is recommended that the communication module should not be used at petrol stations We remind the users of the duty to observe the restrictions concerning the utilization of radio devices at petrol stations in chemical plants or in the co...

Страница 6: ...y for connection to a PC with Windows 2000 Windows XP or Windows Vista operating system For operation it is sufficient to install drivers from the supplied CD to the PC By consumer request it is possible to equip the router with a modulus port PORT1 and extend the functionality of EDGE router about RS232 RS485 RS422 M BUSD or CNT I O module The EDGE router has four versions The first version is th...

Страница 7: ...ion in aluminum box with 2 SIM Specimen label of optional PORT1 Trade name of PORT1 Type name of PORT1 Power supply Expansion port RS232 XC 232 Internal power supply Expansion port RS485 RS422 XC 485 422 Internal external power supply Expansion port M BUSD XC MBUSD External power supply Expansion port CNT XC CNT Internal power supply LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 F...

Страница 8: ...xpansion port RS232 RS485 RS422 M BUSD or CNT separation columns are in distribution USB A B cable Router is standardly designed for mounting to a panel using through holes only version ER 75i and ER 75i DUO or possibility to be put on a worktop mounting onto the DIN rail by the plastic clips which are included 2 3 Antenna Connection The whip antenna is connected to the router using an FME on the ...

Страница 9: ...to supply a peak current of 500 mA 2 6 Technical parameters GSM module MC75i Complies with standards EN 301 511 V9 0 2 EN ETSI 301 489 1 V1 9 1 EN 60950 1 06 ed 2 Frequency bands EGSM850 EGSM900 GSM1800 and GSM1900 Transmit power Class 4 2 W for EGSM850 Class 4 2 W for EGSM900 Class 1 1 W for GSM1800 Class 1 1 W for GSM1900 Temperature range Operation Storage 30 o C to 60 o C 40 o C to 85 o C Prot...

Страница 10: ...Slot and receive in two EDGE multi slot class 10 the maximum bit rate of reception is 118 4 kb s or transmit in one Time Slot and receive in four GPRS multi slot class 12 the maximum bit rate of reception is 236 8 kb s Supports coding schemes CS1 to CS4 and MCS1 to MCS9 Beware The transmitting and receiving in timeslots depends on the operator networks possibilities 2 7 2 Control microcomputer The...

Страница 11: ...nto the local computer network one RJ45 connector optional PORT1 for connection of the local any arrangement over RS232 RS485 422 M BUSD or CNT one FME connector ANT for connection of the antenna one USB B connector USB for connection of the router to the PC Rear panel ER 75i and ER 75i DUO Front panel ER 75i Front panel ER 75i DUO LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax...

Страница 12: ...DESCRIPTION 12 Rear panel ER 75i SL and ER 75i DUO SL Front panel ER 75i SL Front panel ER 75i DUO SL LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 13: ...DC supply voltage 6 GND Negative pole of DC supply voltage Circuit example Panel socket MRT9 Pin number Signal mark Description 1 UN Positive pole of DC supply voltage 10 to 30 VDC 2 GND Negative pole of DC supply voltage Circuit example The positive pole UN is marked by a red socket on the power supply Pin 1 UN Pin 2 NC Pin 3 NC Pin 4 UN Pin 5 GND Pin 6 GND Router DC Pin 1 UN Pin 2 GND Router DC ...

Страница 14: ...Over Ethernet compatible The ETH router connection 2 8 3 Connection of the Connector USB Panel socket USB B Pin number Signal mark Description Data flow direction 1 VCC Positive pole of 5V DC supply voltage 2 USB data USB data signal negative pole Input Output 3 USB data USB data signal positive pole Input Output 4 GND Negative pole of DC supply voltage The USB router connection Router USB ETH POR...

Страница 15: ...a Set Ready connected to 3 3 V over 330 Ohm resistor Output 5 GND GROUND signal ground 6 RXD Receive Data Output 7 CD Carrier Detect Output 8 TXD Transmit Data Input Circuit example The router connection to the PC cable KD2 is connected to serial port PC example COM1 Router ETH PORT1 PWR Cable KD 2 Pin 1 RTS Pin 2 CTS Pin 3 DTR Pin 4 DSR Pin 5 GND Pin 6 RXD Pin 7 CD Pin 8 TXD Router Meter GND RXD ...

Страница 16: ... TxRx RS485 B Input Output 6 TxRx RS485 A Input Output 7 12V EXT External power supply 8 12V EXT External power supply ATTENTION Power supply is selected on the expansion port RS485 by help of a jumper 2 9 If galvanic separation is required the converter must have an external power supply Circuit example of the equipment with a router with data length less than 10 m Router ETH PORT1 PWR Cable KD 2...

Страница 17: ...wer supply ground 2 SGND Signal and power supply ground 3 RxD Receive Data Output 4 RxD Receive Data Output 5 TxD Transmit Data Input 6 TxD Transmit Data Input 7 12V EXT External power supply 8 12V EXT External power supply ATTENTION Power supply is selected on the expansion port RS422 by help of a jumper 2 9 If galvanic separation is required the converter must have an external power supply LUCOM...

Страница 18: ...ss than 10 m Circuit example of the equipment with a router with data length more than 10 m At RS422 data cable more than 10m it is need to use overvoltage protection on the router side LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 19: ...y 8 12V EXT External power supply ATTENTION External supply is for converter M BUSD If galvanic separation is required the converter must have external power supply Circuit example of the equipment with a router with data length less than 10 m Circuit example of the equipment with a router with data length more than 10 m If an M BUS data cable more than 10m it is need to use overvoltage protection...

Страница 20: ...ing of analogue and binary signals and to control settings of binary signals Available are 2 counter and 2 binary inputs or 4 binary inputs 2 analogue inputs and 1 binary output The setting of binaries and counter inputs by the help of firmware in which the single inputs and output is defined Binary output is off in default configuration it is not switched to ground Typical connection of a router ...

Страница 21: ...e length 300Bd 200nF km 1200 m External or internal power supply of module Expansion port RS485 RS422 can be made by wiring jumpers J2 and J3 on this module If external power supply of the module is required jumpers J2 and J3 must be connected to pins 2 3 Internal power supply is made by connecting pins 1 2 with jumpers J2 and J3 Interface behavior of module Expansion port RS485 RS422 can be made ...

Страница 22: ...ronment Storage temperature 20 85 C Emission EN 55022 B Immunity ETS 300 342 Standards Safety EN 60950 Max devices each 1 5 mA 30 Max operating bus current 60 mA Overload detection 100 mA Short circuit strength Permanent Bus voltage mark 36 43 V Bus voltage space 24 31 V M BUS specifications EN 1434 Max total cable length 300Bd 200nF km 1000 m Jumper J2 Jumper J3 Jumper J2 Jumper J3 Jumpery J4 a J...

Страница 23: ...x binary inputs reed contact is J4 20mA is not J4 8µA Inputs Outputs 1x output open collector 100 mA Voltage resistance Permanent Others Sleeping mode Controlled If active level is set as log 1 electric current can be selected with jumper When jumper J4 viz picture is mounted on pins electric current value is 20 mA When jumper J4 is not mounted electric value is 8µA If current value is 20mA CNT ha...

Страница 24: ...ork cable is connected Blinking data transmission Off the network cable is not connected 2 11 Putting into operation Before putting the ER 75i ER 75i DUO ER 75i SL or ER 75i DUO SL router into operation it is necessary to connect all components needed for the operation of your applications and the SIM card must be inserted the modem is off The SIM card must support the GPRS The modem is put into o...

Страница 25: ...DESCRIPTION 25 2 12 Mechanical external dimensions and mounting recommendations LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 26: ...om cables and metal surfaces on every side according to the next picture due to the elimination of interference while using an external antenna except for the switch board it is necessary to fit a lightening conductor before mounting a modem on sheet steel we recommend using an external antenna for single cables we recommend to bind the bunch according to the following picture for this use we reco...

Страница 27: ...unction of the modem we recommend to use in switch board earth bonding distribution frame for grounding of power supply of modem data cables and antenna the circuit diagram of the router is on the following pictures LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 28: ...d removing box top part position 3 connect the expansion port PORT1 position 2 to connector J3 see below of the router B ER 75i motherboard position 1 from the TOP side The expansion port is mounted to the motherboard by the help of three spacers position 7 After mounting the expansion port the box is screwed together by the help of three screws Connector J3 LUCOM GmbH Ansbacher Str 2a 90513 Zirnd...

Страница 29: ...r motherboard 1 2 Expansion port PORT1 1 3 Box top part 1 4 Box bottom part 1 5 Rear head 1 6 Front head 1 7 Spacers for expansion port PORT1 mounting to motherboard 3 8 Screw for box completion 2 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 30: ...ke out the B ER 75i motherboard position 1 The expansion port PORT1 position 2 is connected to connector J3 see below of the router B ER 75i motherboard position 1 from TOP side The expansion port is mounted to the motherboard by the help of three spacers position 9 After mounting the expansion port the box is screwed together by the help of four screws Connector J3 LUCOM GmbH Ansbacher Str 2a 905...

Страница 31: ...xpansion port PORT1 1 3 Left box part 1 4 Right box part 1 5 Rear head 1 6 Front head 1 7 Bottom box part 1 8 Top box part 1 9 Spacers for expansion port PORT1 mounting to motherboard 3 10 Screw for box completion 8 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 32: ... 192 168 1 1 Configuration may be performed only by the user root with initial password root For providing higher security of your network we recommend changing this password More about changing password can be found in chapter 4 26 The left part of the web interface contains the menu with pages for monitoring of the Status Configuration and Administration of the router After green LED starts to b...

Страница 33: ...of networks interface inet own IP address P t P IP address second ends connection Bcast broadcast address Mask mask of network MTU maximal size of packet which is equipment able transmit Metric number of routers over which packet must pass RX packets received packets errors number of errors dropped dropped packets TX packets transmit packets errors number of errors dropped dropped packets collisio...

Страница 34: ...an org doc html 4 4 GPRS Status The item GPRS in the menu contains up to date information about PLMN code of operator cell channel and signal quality of the selected cell as well as neighboring hearing cells In the middle part of window is shows information about transferred data in accounting period The GPRS Connection Log is in the bottom of this window where information about the make up of the...

Страница 35: ...S and formation of IPsec tunnel The upper part of the window displays possible errors at GPRS connection establishment After switching on the log daemon by pressing the Start button the bottom part of the window displays detailed reports from individual applications running in the modem To update the contents of the window press the Refresh button By the help of button Save it is possible to save ...

Страница 36: ...ible to define the DHCP server by checking the Enable dynamic DHCP server option In the window it is possible to define the beginning IP Pool Start and end IP Pool End of the pool of IP addresses which will lease to DHCP clients By parameter Lease time is possible to define time after which the client can use IP address In the fourth part of the Windows it is possible by checking the Enable static...

Страница 37: ...7 Example of the network interface with dynamic DHCP server 192 168 1 3 192 168 1 4 ETH 192 168 1 2 GSM GPRS 192 168 1 1 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 38: ...ith dynamic and static DHCP server 192 168 1 3 192 168 1 4 ETH 192 168 1 2 GSM GPRS 192 168 1 10 01 23 45 67 89 ab 192 168 1 11 01 54 68 18 ba 7e 192 168 1 1 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 39: ... the network interface with default gateway and DNS server 192 168 1 3 192 168 1 4 192 168 1 1 ETH 192 168 1 2 GSM GPRS 192 168 1 20 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 40: ...e to set Check PPP connection flag in the second part of the window The currently active router either main or backup will send testing messages to defined Ping IP Address at periodic time intervals Ping Interval with setting time of waiting for answer Ping Timeout The function check PPP connection is used as a supplement of VRRP standard with the same final result If there are no answers from rem...

Страница 41: ...t number When it is set other phone number it will be use for establish GPRS or CSD connection If the APN field is not filled in then the router automatically selects the APN by the IMSI code of the SIM card If the PLMN operator number format is not in the list of APN then default APN is internet The mobile operator defines APN The PLMN parameter is possible to define in Operator item If the PPPoE...

Страница 42: ... in month when it will start accounting defined in Data limit If the parameter Switch to backup SIM card when data limit is exceeded see next or Send SMS when datalimit is exceeded see SMS configuration are not selected the data limit will not count At the bottom of configuration it is possible to set rules for switching between two APN s on the SIM card in the event that one SIM card is inserted ...

Страница 43: ...he Router tries to make connection with default APN range of this parameter is from 1 to 10000 minutes Parameter Subsequent Timeout sets the time period for every other next attempt to make connection with default APN range is from 1 to 10000 minutes Parameter Additive Constant sets the amount of time which is added to every attempt at main connection establishment after unsuccessful defined attem...

Страница 44: ...CONFIGURATION 44 The changes in settings will apply after pressing the Apply button LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 45: ...dress Protocol and Target Port Parameter Source defines if access is allowed to one IP address which is defined by Source IP Address or every IP addresses In menu Protocol it is possible to specify protocol for remote access it is possible to allow all protocols all or only one protocol UDP TCP or ICMP By parameter Target Port it is possible to specify a port number The changes in settings will ap...

Страница 46: ...ONFIGURATION 46 Example of the firewall configuration 10 0 2 123 171 92 5 45 142 2 26 54 TCP 1000 ICMP ALL LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 47: ...d port number is filled in then configuration of the router over web interface is possible Choice Enable remote FTP access on port and port number makes it possible to access over FTP Choice Enable remote Telnet access and port number makes it possible to access over Telnet Choice Enable remote SNMP access and port number makes it possible to access to SNMP agent Choice Masquerade outgoing packets...

Страница 48: ...ing packets it default server IP address in this case is the address of the device behind the router Connected equipment behind the router must have set Default Gateway on the router Connected device replies while PING on IP address of SIM card 162 209 13 222 192 168 1 2 ppp0 10 0 0 1 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 49: ...on with more connected equipment 162 209 13 222 192 168 1 2 80 192 168 1 3 80 192 168 1 4 80 ppp0 10 0 0 1 SWITCH 10 0 0 1 81 10 0 0 1 82 10 0 0 1 83 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 50: ...ach row for one configured OpenVPN tunnel The column Create switches on tunnels other columns contain values view set in the OpenVPN Tunnel Configuration windows configuration is possible by the Edit button In the window can be defined tunnel name Description and Protocol by which the tunnel will communicate At choice is UDP TCP server or TCP client protocol which has to have defined port protocol...

Страница 51: ...s authentication by CA Certificate Local Certificate and Local Private Key last possibility is X 509 Certificate server which enables authentication by CA Certificate DH Parameters Local Certificate and Local Private Key By the help of parameter Extra Options it is possible to define additional parameters of the OpenVPN tunnel for example DHCP options etc The changes in settings will apply after p...

Страница 52: ...terface IP Address 19 16 1 0 19 16 2 0 Remote Interface IP Address 19 16 2 0 19 18 1 0 Compression LZO LZO Authenticate mode none none 192 168 1 4 192 168 1 3 192 168 1 2 192 168 2 2 192 168 2 3 192 168 2 4 ppp0 10 0 0 1 192 168 1 0 tun0 19 16 1 0 ppp0 10 0 0 2 192 168 2 0 tun 0 19 16 2 0 OpenVPN tunnel Default Gateway 192 168 1 1 Default Gateway 192 168 2 1 A B LUCOM GmbH Ansbacher Str 2a 90513 Z...

Страница 53: ...ly increased to randomize re keying intervals Parameter DPD Delay defines time after which is made Ipsec tunnel verification By parameter DPD Timeout is set timeout of the answer If address translation between two end points of the Ipsec tunnel is used it needs to allow NAT Traversal Enabled If parameter Aggressive mode is enabled then establishing of Ipsec tunnel will be faster but encryption wil...

Страница 54: ...CONFIGURATION 54 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 55: ...nfiguration select the GRE menu item It is possible configure up to four GRE tunnels In the GRE Tunnels Configuration window are four rows each row for one configured GRE tunnel The column Create switch on tunnels other columns contain values view set in the GRE Tunnel Configuration windows configuration is possible by Edit button 192 168 1 4 192 168 1 3 192 168 1 2 192 168 2 2 192 168 2 3 192 168...

Страница 56: ...rks to one that appears as one homogenous Last item Pre shared Key defines 32b number that identifies shared key of tunnel This code must be on both sides of same Attention GRE tunnel doesn t connect itself via NAT The changes in settings will apply after pressing the Apply button Example of the GRE Tunnel configuration GRE tunnel Configuration A B Remote External IP Address 10 0 0 2 10 0 0 1 Remo...

Страница 57: ...range which is offered by server to clients Client Start IP Address end IP address in range which is offered by server to clients Client End IP Address IP address of the local side of the tunnel Local IP Address IP address of the remote side of the tunnel Remote IP Address address of the network behind the remote side of the tunnel Remote Subnet the mask of the network behind the remote side of th...

Страница 58: ... 1 Remote IP Address Remote Subnet 192 168 2 0 192 168 1 0 Remote Subnet Mask 255 255 255 0 255 255 255 0 Username user user Password password password 192 168 1 4 192 168 1 3 192 168 1 2 192 168 2 2 192 168 2 3 192 168 2 4 ppp0 10 0 0 1 192 168 1 1 ppp0 10 0 0 2 192 168 2 1 L2TP tunnel Default Gateway 192 168 1 1 Default Gateway 192 168 2 1 A B LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127...

Страница 59: ...in settings will apply after pressing the Apply button Example of the DynDNS client configuration with domain conel dyndns org username conel password conel and default server http members dyndns org If DNS servers are not assigned by the operator then it is possible to configure it by inserting of script into start up window echo nameserver xxx xxx xxx xxx et resolf conf where xxx xxx xxx xxx is ...

Страница 60: ...The changes in settings will apply after pressing the Apply button Example of the NTP configuration with set primary and secondary NTP server and with daylight saving time 4 18 SNMP Configuration To enter the SNMP Configuration it is possible with SNMP agent ver 1 configuration which sends information about the router eventually about the status of the expansion port CNT or M BUSD The Community it...

Страница 61: ...6 1 4 1 30140 2 1 8 0 Binary input BIN4 values 0 1 For the expansion port M BUSD the following range of OID is used OID Description 1 3 6 1 4 1 30140 2 2 address 1 0 IdNumber meter number 1 3 6 1 4 1 30140 2 2 address 2 0 Manufacturer 1 3 6 1 4 1 30140 2 2 address 3 0 Version specified meter version 1 3 6 1 4 1 30140 2 2 address 4 0 Medium type of metered medium 1 3 6 1 4 1 30140 2 2 address 5 0 S...

Страница 62: ...window there is possible to enter login values to e mail server from which e mails will be sent The required values are address of SMTP server Server Address login name Username password and e mail address Email Address It is possible to send only one file in attachment After that is possible to send e mail messages by using this command email T recipient address S subject M message body A path to...

Страница 63: ...While filling of one two or three numbers it is possible to control the router with the help of an SMS sent only from these numbers While filling of sign it is possible ro control the router with the help of an SMS sent from every numbers Control SMS message doesn t change the router configuration If the router is switched to offline mode by the SMS message the router will be in this mode up to ne...

Страница 64: ...of cell Channel used channel Level level signal After PPP connect at introduction of the telephone number comes SMS in the form ER75i Unit ID has established PPP connection IP address xxx xxx xxx xxx After PPP disconnect at introduction of the telephone number comes SMS in the form ER75i Unit ID has lost PPP connection IP address xxx xxx xxx xxx LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127...

Страница 65: ...CONFIGURATION 65 Configuration of sending this SMS is following LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 66: ...CONFIGURATION 66 Example of the router configuration for SMS sending via serial interface LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 67: ...CONFIGURATION 67 Example of the router configuration for controlling via SMS from every phone numbers LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 68: ...do with SMS by the help of the next AT commands more about AT commands see reference 1 AT commands Description AT CMGF 1 Set the text mode for SMS writing AT CMGS tel number Commands enables to send SMS on entered tel number AT CMGL ALL List of all SMS messages AT CMGR index Read of the definite SMS all SMS has our index AT CMGD index SMS delete according to index LUCOM GmbH Ansbacher Str 2a 90513...

Страница 69: ...ALL Enter CMGL index status sender number date time SMS text CMGL 1 REC UNREAD 420721123456 08 02 02 10 33 26 04 Hello World Where index is ordinal number of the SMS status is SMS status REC UNREAD SMS unread REC READ SMS read STO UNSENT stored unsent SMS STO SENT stored sent SMS ALL all SMS messages sender number is tel number from which the SMS was receive date is date of SMS received time is ti...

Страница 70: ...d final TCP port At Check TCP connection it activates verification of coupled TCP connection Inside the window can be define time after which it will carry out verification of the connection Keepalive Time waiting time on answer Keepalive Interval and number of tests Keepalive Probes The changes in settings will apply after pressing the Apply button In case of M BUS expansion board installed and w...

Страница 71: ...ettings Mode TCP client Server Address 10 0 0 2 TCP Port 2000 192 168 1 100 ppp0 10 0 0 1 192 168 1 1 ppp0 10 0 0 2 PC application settings TCP connection on 10 0 0 2 2000 ER 75i settings Mode TCP server Server Address TCP Port 2000 ETH RS232 PC PLC Default Gateway 192 168 1 1 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 72: ...ply button 4 22 1 IO program Program io can be used to set binary outputs syntax io set out0 out1 0 1 and get state of binary inputs syntax io get bin0 bin1 bin2 bin3 bin4 This is an example how to read inputs by using this program while true do io get bin4 BIN4 if BIN4 OLD4 then if BIN4 1 then gsmsms 739546801 test SMS bin4 1 fi if BIN4 0 then gsmsms 739546801 test SMS bin4 0 fi OLD4 BIN4 fi slee...

Страница 73: ...bin3 1 fi if BIN3 0 then gsmsms 739546801 test SMS bin3 0 fi OLD3 BIN3 fi sleep 2 done Change take effect after restarting router by the help of button Reboot in web administration or by SMS message LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 74: ... choice enables that the router automatically downloads the configuration and the newest firmware from the server itself The configuration and firmware are stores on the server By Enable automatic update of configuration it is possible to enable automatic configuration update By parameter Base URL it is possible to enter base part of the domain or IP address from which the configuration file will ...

Страница 75: ...the Change Profile menu item Profile switch is making by press the button Apply Change take effect after restarting router by the help of button Reboot in web administration or by SMS message It is possible select the standard profile or up to three alternative profiles It is possible to copy actual configuration to selected configuration by selecting Copy settings from current profile to selected...

Страница 76: ...tre because of SMS sending This parameter cannot be set when the SIM card has set phone number of the SMS service centre The phone number can to have formed without international prefix xxx xxx xxx or with international prefix for example 420 xxx xxx xxx 4 29 Unlock SIM Card Possibility to unlock SIM PIN is under Unlock SIM Card item If the inserted SIM card is secured by a PIN number enter the PI...

Страница 77: ...st to phone number 420712345678 Authorization is in the format user password coded by BASE64 example is for root root 4 31 Backup Configuration The router configuration is possible to save by help of the Backup Configuration menu item After clicking on this menu it is possible to check a destination directory where it will save the router configuration 4 32 Restore Configuration In case it is need...

Страница 78: ...e IP address By actualization older firmware than 1 1 1 the IP address will be set on 192 168 1 1 and all values are in defaults state From firmware version 2 0 3 is provided simply file name check of new firmware file Upload firmware of different device can cause damage of the router Total update time lasts for 3 4 minutes During updating of the firmware permanent power supply has to be maintaine...

Страница 79: ...restore initial settings of the router by pressing button RST on front panel After press button RST it is restoration of the configuration and reset green LED will be on 4 35 1 LAN Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 80: ...CONFIGURATION 80 4 35 2 VRRP Configuration 4 35 3 Firewall Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 81: ...CONFIGURATION 81 4 35 4 GPRS Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 82: ...CONFIGURATION 82 4 35 5 NAT Configuration 4 35 6 OpenVPN Tunnel Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 83: ...CONFIGURATION 83 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 84: ...CONFIGURATION 84 4 35 7 Ipsec Tunnel Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 85: ...CONFIGURATION 85 4 35 8 GRE Tunnel Configuration 4 35 9 L2TP Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 86: ...CONFIGURATION 86 4 35 10 DynDNS Configuration 4 35 11 NTP Configuration 4 35 12 SNMP Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 87: ...CONFIGURATION 87 4 35 13 SMTP Configuration 4 35 14 SMS Configuration LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 88: ...CONFIGURATION 88 4 35 15 Expansion Port Configuration 4 35 16 Startup Script LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 89: ...CONFIGURATION 89 4 35 17 Up Down Script 4 35 18 Automatic Update LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 90: ...rite email sends an e mail free displaying of informations about memory gsmat AT commend send gsminfo displaying of informations about signal quality gsmsms SMS send hwclock displaying change of time in RTC ifconfig displaying change of interface configuration io reading writing input output pins ip displaying change of route table iptables displaying modification of NetFilter rules kill process k...

Страница 91: ...or MC75i or Siemens AG WM USB Modem Follow the instructions of the wizard and enter the path to the usbmodem inf file Windows will copy the needed files to your computer and configure the modem by assigning a free COM port After completion of copying the files click on the Finish button LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 92: ...ect Siemens AG WM USB Modem in the installed devices list click on Properties select the Details tab and click on the Advanced port settings button Then select the required free COM port from the COM port number menu The change of COM port setting will apply only after disconnection and reconnection of the USB cable LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20...

Страница 93: ... be disabled default server address has to be your web server and the gateway of the web server has to be the IP of router GPRS connection fails Check signal power If signal power is weak you will have to use a better antenna If the environmental cells have a similar signal it will be necessary to use a directive antenna Signal levels have to be in the range 50dBm and 90dBm It is necessary to set ...

Страница 94: ...s badly set up route conditionals of connected equipment or it is bad set up GW FTP doesn t function Router doesn t support the active FTP mode supports the passive mode only RS232 doesn t function It is necessary to verify present the expansion port RS232 Verify present the expansion port RS232 in router configuration in menu external port or verify connection locally by the help Telnet Hyper ter...

Страница 95: ... on this and do not expose to static electricity During cleaning of the modem do not use aggressive chemicals solvents and abrasive cleaners Conel Company hereby declares that the modem narrated in this user s guide fits all basic demands of directive 1999 5 EC R TTE Declaration about consistency was issued and is possible get it at producer LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 ...

Страница 96: ... available recovery techniques to minimize the impact on the environment This product contains high quality materials and components which can be recycled At the end of it s life this product MUST NOT be mixed with other commercial waste for disposal Check with the terms and conditions of your supplier for disposal information LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 0912...

Страница 97: ...laim should be submitted in a state corresponding to the state at the sale Caution The seller does not guarantee that individual settings or data stored in the object of the guarantee claim will be retained When lodging the guarantee claim the customer is obligated to specify the particular defect of the guarantee claim object possibly its symptoms and furthermore the particular right resulting fr...

Страница 98: ...ed by the guarantee a repair not covered by the guarantee the seller shall notify of this fact the customer and the customer shall notify the seller whether he wants to have this defect removed at a price quoted by the seller Precise conditions of the repair not covered by the guarantee will be specified in a drawn up report signed by the customer and seller If the customer does not require the de...

Страница 99: ...ent whether a defect has occurred the product parameters included in the technical documentation of the product are decisive The guarantee shall be terminated in the event of any modification of the object of the guarantee claim or in the event that the serial number of the object of the guarantee claim has been damaged or is illegible due to other reasons LUCOM GmbH Ansbacher Str 2a 90513 Zirndor...

Страница 100: ...100 14 Guarantee certificate Type of the device Serial number Guarantee period in months Seller Date of sale Stamp of the seller LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Страница 101: ... the device into the repair shop Date of completion of the repair by the repair shop Number of the receipt form of the repair shop Guarantee repair YES NO YES NO YES NO YES NO YES NO New serial number of the device IMEI Comments Stamp of the repair shop LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de ...

Отзывы: