Troubleshooting
A-7
Observing Boot Messages
Testing High Memory
ERROR at failed
memory address
This error indicates a startup failure. Record all
information to this point and contact Lucent
Remote Access Technical Support.
PCMCIA slot
(OR-M only)
PCMCIA card type
PCMCIA card type.
ISDN Found in Slot 0 -
Testing memory
(OR-ST, OR-U only)
512K
ISDN interface found. Test of ISDN memory in
progress.
Found x Ports
1, 2, 3
Number of ports detected. Note that S0 is one
port and PCMCIA is another. The ISDN BRI
counts as two ports.
Ether0 active
16K burst - IO
Ethernet interface found; 16Kbps is detected as
the maximum amount of data that can be input
or output at any given time on the Ethernet
interface.
Running ComOS
N/A
If the system becomes suspended at this point
and does not print the next message, the
configuration of nonvolatile RAM has been
corrupted. Refer to the troubleshooting chapter
of the PortMaster Configuration Guide for
instructions on nonvolatile RAM recovery.
PortMaster Console
login:
N/A
System is up and running.
Table A-2
Interpreting the Diagnostic Boot Messages (Continued)
Field
Possible Message
Explanation
Содержание PortMaster OR-HS
Страница 4: ......
Страница 16: ...Subscribing to PortMaster Mailing Lists xvi PortMaster Office Router Hardware Installation Guide ...
Страница 18: ...1 2 PortMaster Office Router Hardware Installation Guide ...
Страница 36: ...Connect an External Modem Optional 2 18 PortMaster Office Router Hardware Installation Guide ...
Страница 46: ...Replacing a Fuse A 10 PortMaster Office Router Hardware Installation Guide ...
Страница 54: ...Ordering Instructions B 8 PortMaster Office Router Hardware Installation Guide ...
Страница 70: ...Index Index 4 PortMaster Office Router Hardware Installation Guide ...