PortMaster

Office Router

Hardware Installation

Guide

OR-HS,OR-LS,OR-M,OR-ST,OR-ST-AP,OR-U,OR-U-AP

Lucent Technologies

Remote Access Business Unit

4464 Willow Road

Pleasanton, CA 94588

510-737-2100
800-458-9966

November 1998

950-1186F

®

Содержание PortMaster OR-HS

Страница 1: ...OfficeRouter HardwareInstallation Guide OR HS OR LS OR M OR ST OR ST AP OR U OR U AP Lucent Technologies RemoteAccessBusinessUnit 4464 WillowRoad Pleasanton CA94588 510 737 2100 800 458 9966 November1998 950 1186F ...

Страница 2: ...designed to provide reasonable protection against radio interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Some components may not have been manufactured by Lucent Technologies Inc If n...

Страница 3: ...CE Marking Directive 93 68 EEC This marking may be found on the base of the unit This equipment has been tested and is compliant with the following European Directives 91 263 EEC Telecommunications Terminal Equipment 73 23 EEC Low Voltage Directive 89 336 EEC ElectroMagnetic Compatibility as amended by 92 31 EEC Pan European Approval BTZ the German Notified Body has issued Pan European Approval to...

Страница 4: ......

Страница 5: ...he EMEA Region xiv For North America Latin America and the Asia Pacific Region xiv PortMaster Training Courses xv Subscribing to PortMaster Mailing Lists xv 1 PortMaster Office Router Overview 2 Installing the PortMaster Office Router Installation Checklist 2 1 1 Choose a Site 2 2 Environment 2 2 Chassis Accessibility 2 2 Air Flow and Cooling 2 2 Power Guidelines 2 2 2 Prepare the Work Area 2 3 Re...

Страница 6: ...pment 2 7 Procedure 2 8 6 Connect an ISDN BRI Line OR ST and OR U 2 8 Required Equipment for the OR ST 2 8 Required Equipment for the OR U 2 8 Procedure 2 9 7 Connect a PCMCIA Modem OR M 2 9 Required Equipment 2 9 Procedure 2 9 8 Connect an Analog Device OR ST AP and OR U AP 2 10 Required Equipment for a Telephone or Fax 2 10 Required Equipment for an External Modem 2 10 Procedure 2 10 Notes on IS...

Страница 7: ... 5 Replacing a Fuse A 8 Required Equipment A 8 Procedure A 8 B Ordering ISDN Service Ordering Instructions B 1 National ISDN 1 or NI 1 Compliant B 3 AT T 5ESS Custom Multi Point B 4 AT T 5ESS Custom Point to Point B 5 Northern Telecom DMS 100 or DMS 100 Custom B 6 C Physical Specifications Size Weight and Interface Specifications C 1 Electrical Specifications C 2 Environmental Specifications C 2 D...

Страница 8: ...on Guide X 21 Cable D 5 RS 530 Cable D 6 Category 5 Twisted Pair Cable for the S T Interface D 7 Category 5 Twisted Pair Cable for the U Interface D 7 Ethernet Specifications D 8 E Modem Specifications PCMCIA Modems E 1 External Modems E 2 Modem Tips E 2 Index ...

Страница 9: ...allation guides are included with most PortMaster products other manuals can be ordered through your PortMaster distributor or directly from Lucent The manuals are also provided as PDF and PostScript files on the PortMaster Software CD shipped with your PortMaster In addition you can download PortMaster information and documentation from http www livingston com ChoiceNet Administrator s Guide This...

Страница 10: ...on Dial In User Service RADIUS software Additional References RFCs Use any World Wide Web browser to find a Request for Comments RFC online RFC 768 User Datagram Protocol RFC 791 Internet Protocol RFC 792 Internet Control Message Protocol RFC 793 Transmission Control Protocol RFC 854 Telnet Protocol Specification RFC 950 Internet Standard Subnetting Procedure RFC 1058 Routing Information Protocol ...

Страница 11: ...ces RFC 1824 Requirements for IP Version 4 Routers RFC 1825 Security Architecture for the Internet Protocol RFC 1826 IP Authentication Header RFC 1827 IP Encapsulating Payload RFC 1828 IP Authentication Using Keyed MD5 RFC 1829 The ESP DES CBC Transform RFC 1877 PPP Internet Protocol Control Protocol Extensions for Name Server Addresses RFC 1878 Variable Length Subnet Table for IPv4 RFC 1918 Addre...

Страница 12: ...labi San Jose CA Cisco Press 1997 ISBN 1 56205 652 2 Internetworking with TCP IP Volume 1 Principles Protocols and Architecture Douglas Comer Upper Saddle River NJ Prentice Hall Inc 1995 ISBN 0 13 216987 8 v 1 Routing in the Internet Christian Huitema Upper Saddle River NJ Prentice Hall PTR 1995 ISBN 0 13 132192 7 TCP IP Illustrated Volume 1 The Protocols W Richard Stevens Reading MA Addison Wesle...

Страница 13: ...mage Italic font Identifies a command line placeholder Replace with a real name or value set Ether0 address Ipaddress Replace Area with the name of the OSPF area Square brackets Enclose optional keywords and values in command syntax set nameserver 2 Ipaddress set S0 destination Ipaddress Ipmask Curly braces Enclose a required choice between keywords and or values in command syntax set syslog Logty...

Страница 14: ...her end user in Europe the Middle East Africa India or Pakistan contact your local Lucent Remote Access sales channel partner For a list of authorized sales channel partners see the World Wide Web at http www livingston com International EMEA distributors html If you are an authorized Lucent Remote Access sales channel partner in this region contact the Lucent Remote Access EMEA Support Center Mon...

Страница 15: ...mail to majordomo livingston com with subscribe portmaster users in the body of the message The mailing list is also available in a daily digest format To receive the digest send email to majordomo livingston com with subscribe portmaster users digest in the body of the message portmaster radius a discussion of general and specific RADIUS issues including configuration and troubleshooting suggesti...

Страница 16: ...Subscribing to PortMaster Mailing Lists xvi PortMaster Office Router Hardware Installation Guide ...

Страница 17: ... Ethernet connections and one of the following WAN connections Model OR M up to two analog telephone lines using a PCMCIA modem and an external modem Model OR ST a single ISDN BRI line ST interface Model OR U a single ISDN BRI line with an integrated network termination NT1 device U interface Model OR ST AP a single ISDN BRI line ST interface with an analog telephone port This product supports the...

Страница 18: ...1 2 PortMaster Office Router Hardware Installation Guide ...

Страница 19: ...nnect a Console 4 Connect an Ethernet Cable 5 Connect a 56Kbps to T1 E1 Line OR HS or Fractional T1 E1 Line OR LS 6 Connect an ISDN BRI Line OR ST and OR U 7 Connect a PCMCIA Modem OR M 8 Connect an Analog Device OR ST AP and OR U AP 9 Turn On Power 10 Log In 11 Set the Network Address 12 Configure the Office Router 13 Connect an External Modem Optional ...

Страница 20: ...t close proximity to heat sources or high levels of electromagnetic interference EMI Chassis Accessibility Provide 3 inches 8cm clearance at the rear of the Office Router for cabling purposes Air Flow and Cooling Provide 3 inches 8cm around all vent openings of the Office Router for proper air flow Power Guidelines Ensure that the power source of the Office Router is properly grounded and falls wi...

Страница 21: ...fety grounds and locate the emergency power switch for the room in which you are working Wear safety glasses when working under any conditions that might be hazardous to your eyes Keep tools away from walk areas where you and others could fall over them Do not work alone if potentially hazardous conditions exist Warning Before working on equipment that is connected to power lines remove jewelry in...

Страница 22: ...tional cables from Lucent specify product code CBL CDB45 The adapter is available from most computer equipment suppliers PC or terminal Procedure 1 Attach the RJ 45 connector to the Office Router console port and attach the DB 25 connector to the console port of a PC or terminal OR M shown 2 Ensure that DIP switch 1 is up OR M shown When the Office Router is turned on with DIP switch 1 up the S0 p...

Страница 23: ...e5 AUI Ethernet 10BaseT Follow these instructions to connect an Ethernet cable to the Ethernet 10BaseT port Required Equipment Category 5 twisted pair cable as specified by the EIA TIA 568 B wiring standard with an RJ 45 connector See Ethernet Specifications on page D 8 for more information This cable is available from most computer equipment suppliers Procedure 1 Connect the cable to the Ethernet...

Страница 24: ...net cable to the Ethernet 10Base5 AUI port Required Equipment RG 11 50 ohm coaxial cable with a DB 15 female connector See Ethernet Specifications on page D 8 for more information This cable is available from most computer equipment suppliers Procedure 1 Connect the cable to the Ethernet AUI port OR U shown Ethernet S0 S1 S2 ISDN U 1 3 2 1186 0009 Ethernet S0 S1 S2 ISDN U 1189 0007 ...

Страница 25: ...o T1 E1 from the telephone company Call your local telephone service provider to order T1 or E1 or fractional T1 E1 service Typically you must pay an installation charge a monthly flat rate service charge and usage charges Note The W1 port requires an external clock signal that can be provided by the telephone company and a channel service unit digital service unit CSU DSU Required Equipment A V 3...

Страница 26: ...twisted pair cable with RJ 45 connectors See Category 5 Twisted Pair Cable for the S T Interface on page D 7 for pinout information One of these cables is shipped with the OR ST One NT1 device for each ISDN BRI S T interface if not supplied by the telephone company NT1 devices are available from most computer equipment suppliers Required Equipment for the OR U One category 5 twisted pair cable wit...

Страница 27: ... Follow these instructions to connect a PCMCIA modem to the PCMCIA slot on the OR M Required Equipment Type 2 PCMCIA modem card See PCMCIA Modems on page E 1 for modem information Cable used to connect the modem card to a wall jack This cable is usually supplied with the modem card Procedure Note Ensure that the PCMCIA modem is facing right side up when it is inserted Refer to the modem manufactur...

Страница 28: ... Required Equipment for a Telephone or Fax Four pin RJ 11 cable This cable is available from most telephone equipment suppliers Required Equipment for an External Modem RJ 45 to DB 25 Male modem cable This cable can be ordered from Lucent Technologies by specifying product code CBL MDB45 See Modem Cable on page D 3 for pinout information Four pin RJ 11 cable This cable is usually shipped with an e...

Страница 29: ...ops one of the B channels connections to allow an outbound voice call Incoming calls If your ISDN service is provisioned to support more than two call appearances the Office Router temporarily drops one B channel of a Multilink PPP session to allow an inbound voice call If your ISDN service does not support more than two call appearances the inbound caller will hear a busy signal This feature is s...

Страница 30: ...sociated with it set u law enables North American T1 areas digital signal attenuation set a law enables International E1 areas digital signal attenuation 9 Turn On Power Follow these instructions to start the Office Router Procedure 1 Attach the power cord to the Office Router and to a properly grounded electrical outlet OR M shown 2 Turn the power switch on OR M shown 3 Verify that the System LED...

Страница 31: ...is active when Ethernet traffic is present The Network LED blinks once for every packet transmitted or received In heavy traffic situations the LED might appear to be solidly lit If the Network LED does not behave in this way see Observing LED Behavior on page A 1 6 Verify that the NT1 LED is active OR U only The NT1 LED blinks eight times per second for approximately 8 seconds after startup If no...

Страница 32: ...1 LED stays solidly lit when ISDN port S1 has established a connection If the S1 LED does not behave this way contact Lucent Remote Access Technical Support 8 Verify that the S2 LED is active OR U and OR ST OR ST shown The S2 LED stays solidly lit when ISDN port S2 has established a connection If the S2 LED does not behave this way contact Lucent Remote Access Technical Support System Link Network...

Страница 33: ...ess Set an IP address and netmask for an IP network or an IPX network number and frame type for an IPX network IP Address Follow these instructions to set an IP address and netmask for the Office Router From the command prompt enter the following information pressing the Enter key after each line Replace the italicized values with values appropriate for your network login root Password Command Com...

Страница 34: ...y PortMaster product PMVision has a Java tree for navigating to the various features of the application The features in PMVision include the following Monitor allows you to dynamically monitor operations of the selected PortMaster product Graph allows you to view modems and sessions on a graph Diagnose diagnoses problems with selected PortMaster products Maintain backs up restores and upgrades sel...

Страница 35: ... on page E 2 for modem information Basic configuration must be completed before an external modem is connected Required Equipment Modem cable with RJ 45 and DB 25 connectors See Modem Cable on page D 3 for pinout information This cable is not included with the Office Router but is available from Lucent Specify product code CBL MDB45 External modem Procedure 1 Attach the RJ 45 connector to the S0 p...

Страница 36: ...Connect an External Modem Optional 2 18 PortMaster Office Router Hardware Installation Guide ...

Страница 37: ...ely causes of the behavior and potential solutions Table A 1 Hardware Problems and Solutions LED Indication Likely Cause Solution System LED does not light Power is not present Check the power switch power cable outlet and fuse For instructions on checking and changing the fuse see Replacing a Fuse on page A 8 During startup the System LED fails to light becomes solidly lit or blinks three times p...

Страница 38: ...low the PortMaster Configuration Guide procedure for network booting and rewriting the contents of nonvolatile RAM Immediately after startup the System LED stays solidly lit or does not light A nonvolatile RAM problem has occurred Contact Lucent Remote Access Technical Support During operation the System LED stays solidly lit or does not light A hardware failure has occurred possibly caused by an ...

Страница 39: ...ink LED is not lit when connected to a 10BaseT Ethernet hub There is no link integrity Verify that DIP switch 3 is up and that you have a working 10BaseT cable properly connected to the Office Router and to the hub Turn the power off and on to activate the DIP switch setting Network LED is solidly lit Heavy traffic can cause the network LED to blink so rapidly that it appears to be solidly lit How...

Страница 40: ...modem card is inserted with the correct side up See Connect a PCMCIA Modem OR M on page 2 9 3 Turn on power see Turn On Power on page 2 12 An undefined difficulty occurred at startup but the cause cannot be determined from LED behavior See the solution column Try starting in console mode and observe the boot messages See Observing Boot Messages on page A 5 If the boot messages do not suggest a sol...

Страница 41: ... 3 Observe the boot messages displayed on the console screen Note Boot messages vary slightly depending on the version of the programmable ROM PROM and ComOS The following example of boot messages is from an OR M Livingston Enterprises Inc Boot Prom Rev K Testing Low Memory Testing System Clock Testing System Memory A000 Checking Boot Rom Starting FLASH Boot Booting From Flash Type Am29F040 Loadin...

Страница 42: ...e Access Technical Support Checking Boot Rom ERROR This error indicates a boot failure Record all information to this point and contact contact Lucent Remote Access Technical Support Starting FLASH Boot N A N A Booting From Flash Type Am29F040 Nonvolatile RAM brand name Loading Image at 0fff0000 RAM address Flash copy complete 320112 Counter for nonvolatile RAM bytes transferred to RAM If the coun...

Страница 43: ...rt and PCMCIA is another The ISDN BRI counts as two ports Ether0 active 16K burst IO Ethernet interface found 16Kbps is detected as the maximum amount of data that can be input or output at any given time on the Ethernet interface Running ComOS N A If the system becomes suspended at this point and does not print the next message the configuration of nonvolatile RAM has been corrupted Refer to the ...

Страница 44: ...ck and replace the fuse in the Office Router Required Equipment 5 32 inch flathead screwdriver 250V 2A fuse Procedure 1 Turn the power switch off and disconnect the Office Router from the power source 2 Detach the power cord from the Office Router 3 Insert a 5 32 inch flathead screwdriver between the fuse door and the chassis and gently pull the fuse door open S1 PC Card Ethernet S0 1186_0021 1186...

Страница 45: ...ing of the fuse is discolored burned replace the fuse The 250V 2A fuse can be inserted from either end 5 Press the fuse door shut until it clicks 6 Reconnect the power cord to the Office Router 7 Turn the power switch on S1 PC Card Ethernet S0 1186_0011 1186 0011 ...

Страница 46: ...Replacing a Fuse A 10 PortMaster Office Router Hardware Installation Guide ...

Страница 47: ...charged an ISDN installation cost a monthly flat rate for service and usage costs 2 When ordering channel provisioning compare the costs of circuit switched voice circuit switched data CSV CSD service and CSD only service and select the less expensive service Although Office Router ISDN models can be used for data transmission only many ISDN providers offer data and voice service at a lower rate t...

Страница 48: ...lations Fax or read the appropriate table to the sales representative National ISDN 1 or NI 1 Compliant see Table B 1 on page B 3 AT T 5ESS Custom Multi Point see Table B 2 on page B 4 AT T 5ESS Custom Point to Point see Table B 3 on page B 5 Northern Telecom DMS 100 or DMS 100 Custom see Table B 4 on page B 6 After you have completed Step 4 proceed to Step 5 on page B 7 ...

Страница 49: ...m number of channels MAXB 2 B1 CSD or CSVD B2 CSD or CSVD D Signaling Number of channels simultaneously connected CSD 2 Channel to be used for data calls CSD CHL Any Number of data calls that can be made simultaneously CSD LIMIT 2 ACT USR Yes Dynamic terminal endpoint identifier TEI Yes Electronic key telephone service EKTS No Maximum number of terminals active on the BRI line MTERM 1 CA PREF 1 Ca...

Страница 50: ...tribute Setting Line 2B D Line code 2B1Q Terminal type TERMTYP A Maximum number of channels MAXB 2 B1 CSD or CSVD B2 CSD or CSVD D Signaling Number of channels simultaneously connected CSD 2 Channel to be used for data calls CSD CHL Any ACT USR Yes Dynamic terminal endpoint identifier TEI Yes EKTS No Maximum number of terminals active on the BRI line MTERM 1 CA PREF 1 Autohold No OneTouch No Displ...

Страница 51: ...gives AT T 5ESS Custom Point to Point switch translation information Table B 3 AT T 5ESS Custom Point to Point Attribute Setting Terminal type TERMTYP A Call appearances 1 Display No Channels for circuit switched voice CSV per dial number DN 1 Channels for circuit switched data CSD per DN 1 ...

Страница 52: ...witch translation information Table B 4 Northern Telcom DMS 100 or Custom DMS 100 Attribute Setting Line 2B D Line code 2B1Q Terminal type TERMTYP A Maximum number of B channels MAXB CHL 2 Circuit switched service Yes CSD CSV channel Any Signaling Functional Dynamic TEI Yes EKTS No Protocol version control 1 Maximum number of programmable keys 3 Release key No Ringing indicator No ...

Страница 53: ... of copper wires brought to your premises or additional inside wiring installed If your ISDN wall jack is an RJ 11 jack four pins like a standard telephone jack use an RJ 11 to RJ 45 cable If it is an RJ 45 jack eight pins use an RJ 45 to RJ 45 cable 7 Get your service profile identifiers SPIDs and directory numbers You need this information to configure the OR U and OR ST The SPID identifies your...

Страница 54: ...Ordering Instructions B 8 PortMaster Office Router Hardware Installation Guide ...

Страница 55: ...es x 8 75 inches 4 3cm x 26 2cm x 22cm Weight 3 9lb 1 8kg Ethernet interface 10BaseT RJ 45 or 10Base5 DB 15 Asynchronous serial interface EIA TIA 232 423 RJ 45 data rates up to 115 200bps PCMCIA Interface OR M only Type 2 data rates up to 115 200bps ISDN interface OR ST only RJ 45 BRI ST interface providing two 64Kbps B channels ISDN interface OR U only RJ 45 BRI with integrated NT1 U interface pr...

Страница 56: ...PortMaster Office Router Table C 2 Electrical Specifications Description Design Specifications Input voltage 110VAC 10 percent 47Hz to 63Hz 1 0A 220VAC 10 percent 47Hz to 63Hz 0 6A Fuse One 250V 2A Power dissipation 10W Memory 1MB RAM 512KB nonvolatile RAM Table C 3 Environmental Specifications Description Design Specifications Operating temperature 32o to 104o F 0o to 40o C Storage temperature 40...

Страница 57: ... to the S0 port See page D 3 V 35 cable connects a T1 E1 line to the to the W1 port See page D 4 X 21 cable connects a T1 E1 line to the to the W1 port See page D 5 RS 530 cable connects a T1 E1 line to the to the W1 port See page D 6 Category 5 twisted pair cable for the S T interface connects an ISDN BRI line to the S T interface See page D 7 Category 5 twisted pair cable for the U interface con...

Страница 58: ... or Terminal Serial Port RJ 45 Name Definition Direction DB 25 DTE Signal 1 RTS Request to Send Output 5 CTS 2 DTR Data Terminal Ready Output 81 1 Pins 8 and 6 in the DB 25 connectors are connected internally DCD 3 TXD Transmit Data Output 3 RXD 4 GND Signal Ground NC2 2 Not connected 5 GND Signal Ground 7 GND 6 RXD Receive Data Input 2 TXD 7 DCD Data Carrier Detect Input 20 DTR 8 CTS Clear to Sen...

Страница 59: ...Table D 2 Modem Cable PortMaster Office Router S0 Serial Port External Modem RJ 45 Name Definition Direction DB 25 DCE 1 RTS Request to Send Output 4 2 DTR Data Terminal Ready Output 20 3 TXD Transmit Data Output 2 4 GND Signal Ground NC 5 GND Signal Ground 7 6 RXD Receive Data Input 3 7 DCD Data Carrier Detect Input 8 8 CTS Clear to Send Input 5 ...

Страница 60: ...le D 3 Synchronous V 35 Cable DB 25 Pin Name V 35 Pin Definition Direction 2 TXD P Transmit Data Output 14 TXD S 3 RXD R Receive Data Input 16 RXD T 4 RTS C Request to Send Output 5 CTS D Clear to Send Input 6 DSR E Data Set Ready Input 7 SGND B Signal Ground 8 DCD F Data Carrier Detect Input 15 ST Y Send Timing Input 13 ST AA 17 RT V Receive Timing Input 19 RT X 20 DTR H Data Terminal Ready Outpu...

Страница 61: ...ction X 21 DB 15 Pin Name 7 B SGND Signal Ground 8 SGND 10 Control B 4 C RTS Request to Send Output 3 Control A 5 D CTS Clear to Send Input 8 F CD Carrier Detect Input 5 Indicate A 3 R RXA Receive Data Input 4 RXA 16 T RXB Receive Data Input 11 RXB 17 V RX CLKA Receive Timing Input 6 CLKA 15 Y TX CLKA Send Timing Input 19 X RX CLKB Receive Timing Input 13 CLKB 13 AA TX CLKB Send Timing Input 2 P T...

Страница 62: ...ynchronous RS 530 Cable PortMaster Port W1 RS 530 CSU DSU Pin Name Definition Direction 2 2 TXD Transmit Data Output 14 14 TXD 3 3 RXD Receive Data Input 16 16 RXD 4 4 RTS Request to Send Output 5 5 CTS Clear to Send Input 6 6 DSR Data Set Ready Input 7 7 SGND Signal Ground 8 8 DCD Data Carrier Detect Input 15 15 ST Send Timing Input 13 12 ST 17 17 RT Receive Timing Input 19 9 RT 20 20 DTR Data Te...

Страница 63: ...sted have no connection Category 5 Twisted Pair Cable for the U Interface Table D 7 gives pinout information for an 8 pin category 5 twisted pair cable with RJ 45 connectors for the U interface Pins not listed have no connection Table D 6 Category 5 Cable for the S T Interface RJ 45 Pin Name Definition Direction 3 TXD Transmit Data Output 6 TXD 4 RXD Receive Data Input 5 RXD Table D 7 Category 5 C...

Страница 64: ... 8 Ethernet Cables Ethernet Type Connector Type Cable Type Transmission Distance 10Base5 AUI 15 pin Dec Intel Xerox DIX for connection to external transceiver RG 11 50 ohm coaxial Trunk segment 1 640 feet 500m maximum Transceiver cable 164 feet 50m maximum Network trunk 8 200 feet 2 500m maximum 10BaseT RJ 45 RJ 45 for 10BaseT Unshielded twisted pair Hub distance 328 feet 100m maximum Repeaters fo...

Страница 65: ... Table E 1 PCMCIA Modems Manufacturer Model Speed AT T KeepInTouch 14 4 V 32bis Cardinal MVP288CC 28 8 V 34 DSI Scout 144DF 14 4 V 32bis Eiger Labs Eiger 14 4 Eiger 28 8 14 4 V 32bis 28 8 V 34 Hayes Optima 14 4 14 4 V 32bis Intel Satisfaction 14 4 V 32bis Megahertz MHZ MHZ XJ2288 14 4 V 32bis 28 8 V 34 Motorola Power Class Lifestyle 14 4 V 32bis 14 4 V 32bis Multitech 2834LT 28 8 V 34 Newcom 14 40...

Страница 66: ...the following Lock the data terminal equipment DTE rate at 115 2Kbps or as high as the modem can operate reliably Raise DCD when a call comes in Reset itself when DTR is dropped Use hardware flow control RTS CTS Answer the telephone on the first ring for dial in use TDK DF1414 DF2814 14 4 V 32bis 28 8 V FC U S Robotics Sportster Sportster Courier 14 4 V 32bis 28 8 V 34 28 8 V 34 ZOOM ZPCMCIA 14 4C...

Страница 67: ... using PMVision 2 16 using the command line interface 2 16 using the ORWizard 2 16 connecting analog device 2 10 console 2 4 Ethernet 10Base5 AUI 2 6 Ethernet 10BaseT 2 5 external modem 2 17 fractional T1 E1 2 7 ISDN BRI 2 8 PCMCIA modem 2 9 T1 E1 2 7 telephone 2 10 console cable D 2 contact information Europe Middle East and Africa xiv Lucent Remote Access technical support xiv mailing lists xv N...

Страница 68: ...2 1 IP address 2 15 IPX address 2 15 ISDN BRI connecting 2 8 long distance carrier B 7 ordering service B 1 site wiring B 7 L LED Link 2 13 Network 2 13 NT1 2 13 observing for troubleshooting A 1 S1 2 14 S2 2 14 System 2 12 Link LED 2 13 login password 2 15 procedure 2 15 Login prompt problems with A 3 M mailing lists subscribing to xv messages on the console checking A 5 interpreting A 6 modem ca...

Страница 69: ...ines 2 2 R references x books xii RFCs x related documentation ix replacing fuse A 8 RS 530 cable D 6 S S1 LED 2 14 S2 LED 2 14 safety recommendations 2 3 site requirements air flow and cooling 2 2 chassis accessibility 2 2 environment 2 2 power guidelines 2 2 wiring for ISDN BRI B 7 specifications cables D 1 electrical and electronic C 2 environmental C 2 Ethernet D 8 modems E 1 support technical...

Страница 70: ...Index Index 4 PortMaster Office Router Hardware Installation Guide ...

Отзывы: