Metropolis
®
AMU Products
Apparatus
code
Comcode
Typical
[W]
Maximum
[W]
Metropolis
®
AMU Gigabit
Ethernet SFP, ZX 1550nm
OMGBET103
109534347
1.0
1.2
Metropolis
®
AMU Gigabit
Ethernet SFP, LX 1300nm
OMGBET102
109526491
1.0
1.2
Metropolis
®
AMU Gigabit
Ethernet SFP, SX 850nm
OMGBET101
109526483
1.0
1.2
Supervision interface
•
F-interface for Craft Interface Terminal via RJ45 connector with metal shell for
grounding (ITM-CIT)
The interface conforms to V.10/RS-232C standards.
•
Q-LAN Interface via RJ45 connector with metal shell for grounding
(Ethernet-10BASE-T)
This interface conforms to IEEE 802.3 Ethernet standards.
Miscellaneous Discrete Inputs/Outputs
•
The user can assign, through the EMS or local workstation, an alarm message and
alarm severity to each of the four miscellaneous discrete inputs (MDIs). They are
equivalent with other system alarms.
•
When receiving power, all four miscellaneous discrete outputs (MDOs) are
normally open. If power is lost, MDO 1’s contacts close (assigned to indicate
power failure). MDO 2-4 are respectively assigned to Prompt alarm, Deffered alarm
and Information alarm.
•
The MDI inputs and MDO outputs are available from a 25 pin SUB-D male
connector.
Environmental conditions
The environmental conditions applicable for the Metropolis
®
AMU:
•
Storage compliant with ETSI 300 019-1-1 Class 1-2, February 1992:
- Temperature range -5°C to +45°C
- Humidity of 5 to 90% without condensation.
•
Transport compliant with ETSI 300 019-1-2 Class 2-3, February 1992:
- Temperature range -5°C to +45°C
- Humidity of 5 to 90% without condensation.
•
The system normally operates with convectional cooling. In specific configurations,
fan cooling is used. For more information about when a fan is recommended, see
“Guidelines for Fan usage” (p. 2-49)
•
CE marking compliant with 73/23/EEC and 89/336/EEC
•
ETSI EMC - The system meets the requirements of EN 300 386-2 V.1.1.3
(december 1997) for equipment installed in locations other than telecom centers.
Product description
System specifications
....................................................................................................................................................................................................................................
2-48
Lucent Technologies - Proprietary
See notice on first page
365-312-847R4.0