Getting Acquainted with the GRF 400
Description of the AC power supply
GRF 400/1600 Getting Started - 1.4 Update 2
October, 1998
1-11
•
units might be swapped at sites having multiple GRF 400 units with different power
supplies.
If you swap power supplies, remember you cannot mix models in the same GRF chassis.
Contact your Lucent sales representative to order the appropriate power supply units.
Astec supplies have a black pull handle as shown in Figure 1-6:
Figure 1-6. Front of Astec AC power supply drawer.
The Artesyn power supply has a silver pull handle as shown in Figure 1-7:
Figure 1-7. Front of Artesyn AC power supply drawer.
Note:
When replacing Astec units in a redundant system with Artesyn (previously Zytec) supplies,
the units can be hot swapped, there is no need to power off the GRF unit. Do not leave one of
each type of supply (one Artesyn and one Astec unit) "mixed" in the GRF 400 for an extended
period of time. To keep the GRF 400 up and running, mixing power supplies during a brief hot
swap is acceptable.
!
CAUTION: This unit has two power supply cords. For total isolation from
electrical shock and energy hazard, disconnect both supply cords.
ACHTUNG: Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät
vollständig von Netz zu trennen ziehen Sie beide Kabel ab,
sonst können Sie einen elektrischen Schlag erhalten.
(This label is present only when
a second supply is installed.)
Black handle
(This label is present only when
a second supply is installed.)
Silver handle
CAUTION: This unit has
two power supply cords.
For total isolation from
electrical shock and
energy hazard, disconnect
both supply cords.
100-240V
ACHTUNG: Dieses Gerät hat zwei
Netzanschlusskabel. Um das Gerät
vollständig von Netz zu trennen ziehen
Sie beide Kabel ab, sonst können Sie
einen elektrischen Schlag erhalten.
ATTENTION: Cet appareil a deux
cordons d’alimentation électrique. Pour
une isolation complète de tout choc
électrique et de danger énergétique,
débrancher les deux cordons
d’alimentation.