Upgrading System Software
Upgrading software
5-2
CellPipe™ 20 Series User’s Guide
Upgrading software
Follow the procedure below to upgrade software:
1
Extract the loads from eSight to your computer.
2
Establish an Ethernet connection between the unit and your computer.
3
Set up IP addresses on the unit and your computer such that you can successfully
ping the unit.
4
Under the DOS prompt on your computer, enter the path to the directory
containing the extracted loads and a file named xupgrade.bat.
5
To start the upgrade, execute command
xupgrade <ipaddress of
unit>
, for example:
C:\>
xupgrade 149.198.65.46
Note:
There is no need to back up your current configuration. Using the
xupgrade.bat file for upgrading will retain your current configuration. The
upgrading process might last as long as 60 seconds.
6
Then enter the
restart
command to reboot the unit.
7
Lastly enter the
save
command to save the new upgrade.
Note:
Maintain stable power to the unit while upgrading software. If power fails
during the upgrading process, contents in the memory could be destroyed and the
system will hang and no longer function.