Configuring a 20 Series CellPipe
Configuring the pat command
4-16
CellPipe™ 20 Series User’s Guide
Select the
addpatin
command to enable a local server’s IP address to be used as a
WAN access port.
>pat> addpatin <pppoa|wanip> <port>/<udp|tcp> <serverip>
Note:
Prior to setting the local server as a WAN access port, you have to enable the
PAT function. See the
setpat
command below.
Select the
delpatin
command to disable the local server as a WAN access port.
>pat> delpatin <all>|<number>
Select the
setpat
command to enable or disable a specific PAT interface.
>pat> setpat <pppoa|wanip> <e>nable|<d>isable
Select the
show
command to display the Pat configuration.
>pat> show
PAT enabled interface:
Interface IP address
IPoA 210.62.2.195
PPPoA?.?.?.?
PAT incoming table
No.
i/f name|WAN IP
Port/Protocol
Server IP
1
pppoa
434/udp
192.62.2.134
2
210.62.2.195
232/tcp
192.62.2.166