Configuring a 20 Series CellPipe
Configuring WAN interface
4-6
CellPipe™ 20 Series User’s Guide
Select the
rx_bin
command to limit the bin number used for special configurations
in the receive signal. Values for bin numbers are between 1 to 255.
>adsl> rx_bin - <start_bin> <end_bin>
Select the
show
command to display the ADSL parameter configuration. For
example:
>adsl> show
ADSL setting:
Current
Ineffective
Local line code
MULTIMODE
MULTIMODE
Trellis encoding
Enabled
Enabled
EC/FDM mode
FDM
FDM
Coding gain
AUTO
2 dB
Transmit Power Attenuation 0 dB
0 dB
Tx Start bin
6 (H)
6 (H)
Tx End bin
1f (H)
1f (H)
Rx Start bin
20 (H)
3 (H)
Rx End bin
ff (H)
4 (H)
Select the
startup
command to restart the ADSL connection.
>adsl> startup
start to re-Sync. ...
Select the
status
command to display the ADSL parameter configuration. For
example:
>adsl> status
ADSL Firmware version ANNEX_A CPE 41000
OP state handshake
Last Failed Status (0)
Start Progress a0
Watchdog Timer 53
Line code
G.DMT
Framing_Overhead_actual 0
Trellis
<disable>
AS0_Dn_Bytes_Actual 0