Configuring a 20 Series CellPipe
Configuring WAN interface
CellPipe™ 20 Series User’s Guide
4-3
Select the
cell
command to enable or disable the idle-cell header.
>sdsl> cell <Enable|Disable>
Select the
dbit
command to configure the sdsl data bit.
>sdsl> dbit <Normal|Reverse>
Select the
default
command to set the SDSL configuration back to factory setting.
>sdsl> default
Set SDSL configuration back to factory setting
Select the
enable
command to activate the last updated SDSL parameters.
>sdsl> <enable > (null)
Select the
rate
command to manually configure the SDSL line rate.
>sdsl> rate - <n*8> (144 <= (n*8) <= 2320)
Select the
maxrate
command to configure the maximum SDSL autobaud rate. For
example:
>sdsl> maxrate
maxrate
- configure the sdsl autobaud max rate
can use
2320K 1568K 1552K 1536K 1168K 1152K 1040K 784K
768K 528K 416K 400K 384K 272K 208K 192K
160K 144K
Select the
rate
command to manually configure the SDSL line rate. For example:
>sdsl> rate
rate
- configure the sdsl line rate
can use
2320K 1568K 1552K 1536K 1168K 1152K 1040K 784K
768K 528K 416K 400K 384K 272K 208K 192K
160K 144K
Select the
scramble
command to enable or disable payload scrambling.
>sdsl> scramble <Enable>|<Disable>
Select the
smbit
command to configure sign and magnitude bit sequence.