background image

Installation Instructions                                                           

 

4 | P a g e  

 

v 1 . 0   ( 1 0 / 2 0 1 8 )        

 

SENSOR TESTING: 

 

Slide the LUX control switch S1 (

) to the left position and the TIME control switch S3 (5”) to the right position. 

Turn the wall switch on and the light will turn on and remain on for about 15 seconds for the “warm-up” mode. After 

this initial “warm up” mode the light will turn off and the luminaire will be in AUTO MODE. 

 

Have someone walk across the centre of the area to be scanned until the luminaire can sense the moving person 

and causes the light to switch on. 

 

Adjust the TIME control switches (S3-S8) to the desired length of time for the luminaire to remain on. 

 

Adjust the LUX control switch to achieve the ideal ambient light for the luminaire to switch “on”. 

 

MANUAL MODE: (Sensor Override Function) 

Manual mode is used when you want the LED lights to be constantly on. The PIR sensor will be disabled and not affected 

by the duration time and lux level settings. The maximum duration for manual mode is 24 hours. 

 

During normal use the  wall switch  is in the ON position and the  luminaire is  in AUTO MODE  with the  PIR sensor 

detecting any movement and the LED lights will switch on and off accordingly. 

 

To switch into MANUAL MODE, turn the wall switch off and on twice within three seconds.   

Wall switch action: OFF 

 ON 

 OFF 

 ON.   

Wait for 3 seconds and the LED lights will turn on and the luminaire will be in MANUAL MODE.   

NOTE: If the wall switch action is done only once or more than twice, the luminaire will not enter into MANUAL MODE.   

 

To change back to AUTO MODE, turn the wall switch off and on, the luminaire will enter “warm-up” mode and the 

LED light will remain on for about 15 seconds. After this the LED lights will turn off and the luminaire will be in AUTO 

MODE. 

Wall switch action: OFF 

 ON 

 

Safety tips 

 

Always ensure the power is OFF and the luminaire has cooled down before performing any maintenance, cleaning, 

changing the globe or making any adjustment to the luminaire. 

 

To  avoid  injury  or  damage  to  the  luminaire,  ensure  that  power  leads  and  screws  are  secure  before  connecting  the 

power. 

 

The luminaire must not be used if the shade has been cracked. Replace any cracked protective shield. 

 

Ensure that the luminaire does not come in contact with corrosive chemicals/solvents or abrasive cleaners etc. 

 

To clean, wipe with a damp clean cloth. Do NOT soak or immerse the product in water or other liquids. 

 

Specifications

 

SKU # 

240735 

240736 

240737 

Colour 

Black 

304 stainless steel 

316 stainless steel 

Rated Voltage 

220-240V~ 50Hz 

Rated Wattage 

20W Max. (Use 2 x Max.10W globes, LED Only) 

Lamp Holder 

GU10 

IP Rating 

IP65 

Weight 

0.9kg 

1.6kg 

1.6kg 

Dimensions 

H:250mm    W:310mm    E:215mm

 

 

Отзывы: