![Lubeworks 1813351 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/lubeworks/1813351/1813351_instruction-manual_1945588012.webp)
TECHNICAL
DETAILS
INTENDED USE
FACTORY SETTINGS
TOOL USE
EXPLODED AND
PARTS LIST
OPERATION
TROUBLE
SHOOTING GUIDE
E10
Press again to modify the value to
equal the volume of the calibrated
container.
Press key “10” to increase
the indicated value.
Press key “0.1” to decrease
the indicated value.
WARNING
After dispensing, wait a few
minutes to allow any air bubbles in
the calibrated container to
dissipate. Verify the actual amount
dispensed in the calibrated
container; as the air bubbles
dissipate, the indicated level may
decrease. Do not wait more than
15 minutes as the Meter will exit
from the menu and it will no longer
be possible to complete the
calibration operation.
The Meter is ready to accept the
modification of the indicated value to
correspond to the real value. A key each
time is pressed, the last digit on the right is
modified under one unit.
AUTO
After correction:
Press again, the Meter will
calculate
the K Factor automatically which is blinking.
The Meter stores the new Calibration
Factor (K Factor) and displays:
Blinking New K Factor
After a few seconds, the Meter
automatically exits from the customization
mode and starts using the new Calibration
Factor.
One dispensing operation is enough to
carry out the on-site calibration of the
meter.
If you wish to verify the result of this
calibration,
complete a normal
dispensing in the same Calibrated
Container
without re-entering the
calibration function in the Customization
menu.
Attention: In order to preserve the unit
setting, must be hold for 2s after
accomplishing setting and programme will
be saved until the start of next function
setting. If setting preservation in flash in
case of power-off is needed, it is essential
to wait for 30s without operation until the
screen disappears and the setting will be
written in flash then.
Indicated value
Blinking
Real value
6.95
Meter
Calibrated Container
6.90
Lit
CAL
Indicated value
Blinking
Real value
6.95
Meter
Calibrated Container
6.90
Lit
CAL
10
0.1
10
0.1
CRL
Lit
1-003
AUTO
OK/STOP