![LTO CONTROL60 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/lto/control60/control60_user-manual_1945170013.webp)
PROGRAM CHANGE
Parameter
Value
Legend
Preset 01 to preset 06
0, 1, 2, 3, 4, 5
Graphic Equalizer 2x30 dual mono
Preset 07 to preset 12
6, 7, 8, 9, 10, 11
Graphic Equalizer 2x30 stereo
Preset 13 to preset 18
12, 13, 14, 15, 6, 17
Graphic Equalizer 1x60 mono
Preset 19 to preset 24
18, 19, 20, 21, 22, 23
Parametric Equalizer 2x30 dual mono
Preset 25 to preset 30
24, 25, 26, 27, 28, 29
Parametric Equalizer 2x30 stereo
Preset 31 to preset 36
30, 31, 32, 33, 34, 35
Parametric Equalizer 2x30 mono
Preset User
36,..................., 98
User
Notes:
If the system is in
whatever program change command is ignored.
bypass
If the EQ type is Graphic or Parametric
, please first af all select the channel on which to load
dual mono
the preset.
CONTROL CHANGE
5. MIDI STANDARD CONTROL
Control60 Midi standard control
Parameter
Controller
Value
Bank
Legend
System Bypass
System Bypass
86
86
0
1
0=No Bypass; Led Off
1 = Bypass; Led ON
Bank
Bank
0
0
0, 1, 2
3, 4, 5
0, 1, 2 = channel Left
3, 4, 5 = channel Right
Output Volume
7
0,..., 48
0 = channel L;
3 = channel R
12 /
12 dB
Input Gain
83
0,..., 48
0 = channel L;
3 = channel R
12 /
12 dB
Delay Line Adj
Delay Line Fine
82
82
0,..., 127
0,..., 95
0 = channel L;
3 = channel R
1 = channel L;
4 = channel R
508 ms step 4ms
1995 us step 21us
High Pass Filter
High Pass Filter
80
80
0,..., 120
0, 1, 2
0 = channel L;
3 = channel R
1 = channel L;
4 = channel R
HP Frequency
HP Order
Low Pass Filter
Low Pass Filter
81
81
0,..., 120
0, 1, 2
0 = channel L;
3 = channel R
1 = channel L;
4 = channel R
LP Frequency
LP Order
Filer 01, 02,..., 20
Filer 01, 02,..., 20
Filer 01, 02,..., 20
12, 13,..., 31
12, 13,..., 31
12, 13,..., 31
0,..., 60
0,..., 120
0,..., 59
0 = channel L;
3 = channel R
1 = channel L;
4 = channel R
2 = channel L;
5 = channel R
Amplitude
Frequency
Band Width
Filer 21, 22,..., 30
Filer 21, 22,..., 30
Filer 21, 22,..., 30
70, 71,..., 79
70, 71,..., 79
70, 71,..., 79
0,..., 60
0,..., 120
0,..., 59
0 = channel L;
3 = channel R
1 = channel L;
4 = channel R
2 = channel L;
5 = channel R
Amplitude
Frequency
Band Width
Mode
Mode
84
84
0
1
Mode=0 select filter 01 to filter 30
Mode=1 select filter 31 to filter 60
Equ. Type
Equ. Type
85
85
0, 1, 2
3, 4, 5
0 = G2x30DM; 1 = G2x30St; 2 = G1x60M;
3 = P2x30DM; 4 = P2x30St; 5 = P1x60M;
12
Power Switch With LED (1)
Turns the apparatus on and off. Press the SW, the power LED inside the SW will turn on.
Dial Control Knob (10)
Used only to change editable values.
3.2 The Rear Panel
Input (19/20)
These are XLR balanced connectors which connect to sources such as the channel inserts of mixing consoles.
They may be used with nominal input levels from consumer to professional audio.
Outputs (21/22)
These are XLR balanced connectors which connect to devices such as the channel inserts on a mixing console
or power amplifier input. For mono applications, use the output1 and/or output2.
MIDI Connectors
MIDI in (23): 5-poles DIN connector for the MIDI input to the CONTROL60.
MIDI thru (24): 5-poles DIN connector for the MIDI thru.
MIDI out (25): 5-poles DIN connector for the MIDI output from the CONTROL60.
Power Connector (26)
This is an IEC 3-pole socket for connecting the AC power supply to the CONTROL60.
4. INSTALLATION & CONNECTION
4.1 Power Up and Audio Connections
a. Audio Connections
b. Power Up Setting
The connections between the CONTROL60 and the other audio devices have to be made using high quality
cables so to prevent bad performances of the CONTROL60 itself. So it should be good to use low-capacitance
shielded cables with a flexible internal conductor. Connect the cables to the CONTROL60 properly by observing
the following precautions:
Do not bundle audio cables with AC power cords.
Do not place audio cables and CONTROL60 near sources of electromagnetic interference such as:
Transformers, monitors, computers, etc.
Always unplug cables by firmly grasping the body of the plug and pulling directly outward.
Do not place cables where they can be stepped on.
Before turning on the CONTROL60's power, check if:
All connections have been made correctly.
The volume controls of the amplifier or mixer are turned down.
Insert the Power plug into the POWER input on the rear panel of the CONTROL60 and plug the power cord into
an AC outlet.
Turn on the power of the CONTROL60, pushing the ON/OFF button on the front panel.
Turn on the power of the amplifier/mixer, and adjust the volume.
13.Up key
14.Right key
15.Down key
16.Left key
17.LCD graphical display 128
64
18.Vu-meter
INPUT1
INPUT2
OUTPUT1
OUTPUT2
INPUT
THRU
OUTPUT
MIDI
AC INPUT
95-240V
60-50Hz
Rated Power Consumption 15W
FUSE:
210-240V: T250mAL 250VAC
95-120V: 500mA 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till
jordat uttag nar den ansluts
till ett natverk
25
24
23
22
21
20
19
26
5
PUSH
2
1
3
NEW
TIDE
PUSH
2
1
3
NEW
TIDE
Avoid twisting a cable or having it make sharp, right angle turns.
SERIAL
MODEL
CODE