background image

Page 3 of 8

1. Attach Feet

Attach one of the adhesive-backed rubber feet to the recess in each of the four corners on
the bottom of the modem (

Figure 3

).

Figure 3. Attach Feet

2. Wall Mounting (Optional)

Mounting holes on the bottom of the modem provide the option to mount the modem on a
wall. Two Phillips head screws are provided per MM300SBP-G2.

Figure 4. Wall Mount

Rubber Feet

Recess

Step

Action

1

Use 

Figure 4

 as a guide for wall mounting. You can also use the enclosed Wall 

Mount template.

2

Leave enough space to read the front panel LEDs.

3

If you have more than one modem, refer to 

Protecting Multiple MM300SBP-G2 

Units from Overheating on page 2

.

.50"

4.85"

8.5"

3.0" (min.)

1.0"

Содержание MM300SBP-G2

Страница 1: ...s place at modem start up and is completely automatic By bridging traffic between these two modems you essentially create one extended LAN that allows the use of a single IP subnet FEATURES The MM300S...

Страница 2: ...cooling vents Power Adapter Input 100 240 VAC 50 60 Hz 0 3 A Output 6 VDC 1 8 A Ethernet Link Transmit Receive Collision DSL Sync Transmit Receive Margin Ethernet Connector LAN Interface RJ 45 connect...

Страница 3: ...odem provide the option to mount the modem on a wall Two Phillips head screws are provided per MM300SBP G2 Figure 4 Wall Mount Rubber Feet Recess Step Action 1 Use Figure 4 as a guide for wall mountin...

Страница 4: ...use the Black straight through cable To connect the modem to an Ethernet switch use the Yellow cross over cable Connect binding post connectors for the DSL interface Connect the Power Earth Ground Pow...

Страница 5: ...ceiving a Frame Off No Current Reception On Margin is At or Above Margin Threshold Off Margin is Below Margin Threshold LED State Description PWR On green Modem has power Off Modem does not have power...

Страница 6: ...t up or handshaking sequence Fast flashing green indicates that the DSL transceiver is in training sequence Off Power is not connected Admin State disable TX Flashing green Modem is transmitting data...

Страница 7: ...gure 10 Figure 10 Maximum Data Rate Vs Distance and Wire Gauge 0 128 256 384 512 640 768 896 1 024 1 152 1 280 1 408 1 536 1 664 1 792 1 920 2 048 2 176 2 304 Kft Km Data Rate in Kbps 0 0 0 3 0 6 0 9...

Страница 8: ...hat are not expressly approved by LTI DataComm voids the user s warranty All wiring external to the products should follow the provisions of the current edition of the National Electrical Code MAILING...

Отзывы: