background image

Page 8 of 8

H

OW

 

TO

 O

BTAIN

 LTI D

ATA

C

OMM

 D

OCUMENTATION

Copies of this Quick Installation Guide can be downloaded from the LTI DataComm website at

http://www.ltidata.com/customers/index.html

. To order a hard copy, please contact your

sales representative.

S

PECIFIC

 D

ISCLAIMER

 

FOR

 H

IGH

-R

ISK

 A

CTIVITIES

This product is not designed or intended for use in high-risk activities including, without
restricting the generality of the foregoing, online control of aircraft , air traffic, aircraft navigation
or aircraft communications; or in the design, construction, operation or maintenance of any
nuclear facility. LTI DataComm (including its affiliates) and its suppliers specifically disclaim any
express or implied warranty of fitness for such purposes or any other purposes.

FCC C

LASS

 B C

OMPLIANCE

This device complies with Part 15, Class B of the FCC rules. Operation is subject to the following
two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

Consult the dealer or an experienced radio/TV technician for help.

L

IMITED

 W

ARRANTY

Product warranty is determined by your service agreement. Contact your sales representative
or Customer Service for details.

M

ODIFICATIONS

Any changes or modifications made to this device that are not expressly approved by LTI
DataComm voids the user's warranty. All wiring external to the products should follow the
provisions of the current edition of the National Electrical Code.

M

AILING

 A

DDRESS

To contact LTI DataComm by mail:
LTI DataComm
23020 Eaglewood Ct - Suite 100
Sterling, VA  20166-9503

T

ECHNICAL

 S

UPPORT

Technical assistance is available 24 hours a day, 7 days a week by contacting the LTI
DataComm Customer Service at:
Email: 

[email protected]

Telephone: 1.800.677.5050 (toll-free) or 1.703.581.6868
Fax: 1.703.581.6861
Web: 

http://www.ltidata.com/

 (click on 

Contact

 

at the far right top of the screen)

Megabit Modem MM300SBP-G2

Quick Installation Guide

Product Catalog: MM300SBP-G2

Document: MM300SBP-G2-QI-A1

Issued September 19, 2011

´>Æ!h|('¨

300001729208

R

EVISION

 H

ISTORY

© 2011 LTI DataComm. All rights Reserved.

LTI DataComm and LTI (logo) are registered trademarks of LTI DataComm. Megabit Modem is a registered
trademark of ADC Telecommunications, Inc., a TE Connectivity Ltd. company.  No right, license or interest to
such trademarks is granted hereunder, and you agree that no such right, license or interest shall be asserted
by you with respect to such trademark.

Other product names mentioned in this practice are used for identification purposes only and may be
trademarks of their respective companies.

Information contained in this document is company private to LTI DataComm, and shall not be modified, used,
copied, reproduced or disclosed in whole or in part without the written consent of LTI DataComm.

Contents herein are current as of the date of publication. LTI DataComm reserves the right to change the
contents without prior notice. In no event shall LTI DataComm be liable for any damages resulting from loss of
data, loss of use, or loss of profits, and LTI DataComm further disclaims any and all liability for indirect,
incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products,
publications and services during and after the warranty period.

Rev

Date

Revisions

A1

9/19/2011

Initial Release.

)

../6!4)6%

#

/--5.)#!4)/.3

3

/,54)/.3

Содержание MM300SBP-G2

Страница 1: ...s place at modem start up and is completely automatic By bridging traffic between these two modems you essentially create one extended LAN that allows the use of a single IP subnet FEATURES The MM300S...

Страница 2: ...cooling vents Power Adapter Input 100 240 VAC 50 60 Hz 0 3 A Output 6 VDC 1 8 A Ethernet Link Transmit Receive Collision DSL Sync Transmit Receive Margin Ethernet Connector LAN Interface RJ 45 connect...

Страница 3: ...odem provide the option to mount the modem on a wall Two Phillips head screws are provided per MM300SBP G2 Figure 4 Wall Mount Rubber Feet Recess Step Action 1 Use Figure 4 as a guide for wall mountin...

Страница 4: ...use the Black straight through cable To connect the modem to an Ethernet switch use the Yellow cross over cable Connect binding post connectors for the DSL interface Connect the Power Earth Ground Pow...

Страница 5: ...ceiving a Frame Off No Current Reception On Margin is At or Above Margin Threshold Off Margin is Below Margin Threshold LED State Description PWR On green Modem has power Off Modem does not have power...

Страница 6: ...t up or handshaking sequence Fast flashing green indicates that the DSL transceiver is in training sequence Off Power is not connected Admin State disable TX Flashing green Modem is transmitting data...

Страница 7: ...gure 10 Figure 10 Maximum Data Rate Vs Distance and Wire Gauge 0 128 256 384 512 640 768 896 1 024 1 152 1 280 1 408 1 536 1 664 1 792 1 920 2 048 2 176 2 304 Kft Km Data Rate in Kbps 0 0 0 3 0 6 0 9...

Страница 8: ...hat are not expressly approved by LTI DataComm voids the user s warranty All wiring external to the products should follow the provisions of the current edition of the National Electrical Code MAILING...

Отзывы: