R-Log – Quick Start 

 

Cod. INSTUM_00953 

Pag. 3 

 

 

1.

 

Introduction 

 
This manual is an introduction to the use of the R-Log datalogger. 
Reading this manual will allow you to perform the basic operations for starting this device. 
 
Refer to 

GidasTea – User manual 

(code SWUM_00662) and particularly to the 

Step-by-step Guide 

accessible  from 

menu  of  GidasTEA  program  for  applications  requiring  the  calculation  of 

microclimate indexes.  

 

For special applications, such as - for example – the use of specific communication devices (modem, 
communicators, Ethernet/RS232 converters etc.) or where the implementation of actuation logics or 
the  setup  of  calculated  measurements  is  requested,  please  refer  to  the  R-Log  and 

3DOM

  software 

User  Manuals,  that  are  included  in  the 

MW6501  -  LSI  LASTEM  Products 

DVD

 

in  the 

Manuals

  – 

DOCUMENTS

 section.  

 
 

2.

 

To start… 

 
There are the following models of R-Log:  
 

Model 

Connector 

inputs 

Terminal 

board 

inputs 

Master 

mode 

Repeater 

mode 

Slave 

mode 

Ethernet 

output 

ELR510M 

ELR510R 

ELR510S 

ELR515M 

X  

ELR515R 

ELR515S 

ELR516M 

 
Additionally,  R-Log  is  compatible  with  the  following  sensors  provided  with  radio  communication 
(S-Log): 
 

o

 

ELR200

: environment sensors for temperature/ relative humidity;

 

o

 

ELR205

: black globe and wet bulb temperature sensors;

 

o

 

ELR210

: 2- temperature contact sensor.

 

 
The  instrument  model  is  indicated  on  the  label  located  on  the  back  of  the  instrument  and  in  the 
information displayed by the datalogger during the first boot phases (§3.2.1). 
 
 

3.

 

First installation 

 
Basic  operations  for  turning  the  instrument  on  depend  on  the  installation  typology  to  be 
implemented:  from  the  simplest,  consisting  of  a  single  Master  datalogger  (Fig.  1),  to  the  more 
complex, consisting of a Master instrument and of one or more Slave/Repeater devices (Fig. 2 and 
Fig. 3). 

Содержание ELR510M

Страница 1: ...Cod MW6165 R Log Quick Start Update 01 25 2016...

Страница 2: ...g a configuration report 14 3 4 Connecting the probes 14 3 4 1 Electrical connection 14 3 5 Displaying measures in fast acquisition mode 16 3 6 Starting the system and displaying measurements 16 4 Ela...

Страница 3: ...DOCUMENTS section 2 To start There are the following models of R Log Model Connector inputs Terminal board inputs Master mode Repeater mode Slave mode Ethernet output ELR510M X X ELR510R X X ELR510S X...

Страница 4: ...R Log Quick Start Cod INSTUM_00953 Pag 4 Legenda ________ cable connection _ _ _ _ _ _ radio connection Fig 1 A type installation Fig 2 B type installation Fig 3 C type installation...

Страница 5: ...each Slave Repeater datalogger with 3DOM software Configuration of the Master datalogger with measurements imported by Slave Repeater devices Generation of a Configuration Report for each datalogger C...

Страница 6: ...Information Installation in the SOFTWARE section Follow the instructions indicated under Guided Installation of LSI LASTEM programs paragraph 3 1 2 3DOM Software Through 3DOM software you can perform...

Страница 7: ...he instrument Insert the instrument in 3DOM Check the instrument s internal clock Create the configuration in 3DOM Send the configuration settings to the instrument For ELR510M ELR510S and ELR510R mod...

Страница 8: ...the screen for about 10 seconds when the window disappears the survey will be automatically started based on the last configuration stored before the instrument shutdown Refer to 3 2 4 if the system...

Страница 9: ...is mandatory and cannot be cancelled In order to have accurate time data the datalogger internal clock should be correct Failing this the clock can be synchronized with that of your computer through...

Страница 10: ...program list Select your instrument serial number in the Instruments panel Select the name of the basic configuration in the Configurations panel user000 by default Press the selected name with the ri...

Страница 11: ...sors registry or you want to connect it to the datalogger in single ended mode in this case refer to the instrument user manual press the New button to add a measure entering all the parameters reques...

Страница 12: ...the instrument The association between input and actuator is fixed and follows the table shown in 3 4 To set an actuation logic proceed as follows Select Logics from the Actuators section Select the...

Страница 13: ...tted via radio to the Master instrument must be entered in the latter as serial measurements To do so proceed as follows Select Measures in the General Parameters section Press Import button to start...

Страница 14: ...later when connecting the probes to the datalogger 3 4 Connecting the probes It is recommended to connect the probes with the instrument turned off 3 4 1 Electrical connection For ELR516M and ELR515...

Страница 15: ...Rx A B C D Current signal from 4 wires sensor powered fixed or switched from E Log 0 V 12V fixed or switched Probe power supply Rx A B C D Rx Current signal from 2 wires probe powered from signal wir...

Страница 16: ...activate the fast acquisition mode proceed as follows Turn the instrument on by simultaneously pressing and buttons Press simultaneously and buttons in the instant values display window Check when pos...

Страница 17: ...me based on the selected settings Basic folder Serial number Prefix _ Serial number _ yyyyMMdd_HHmmss txt Note If the setting Append data on the same file is not selected each time instrument data are...

Страница 18: ...Pag 18 To enable storage select Check to activate data storage control box The list shows the current connection status This can be changed by pressing the Select key that opens the configuration wind...

Страница 19: ...configuration of the programs that use the removed data source and that will continue to use it The timeout for data requests from the database can also be changed To add a new connection select the...

Страница 20: ...ted instrument the Download button is enabled proceed then as follows Select the date from which to start downloading data in case some data were already been downloaded the control proposes the date...

Страница 21: ...Select the identified acquisition with the starting date time of measurements Press the selected acquisition with the right key of your mouse and choose Show Data for the wind direction measurement s...

Страница 22: ...R Log Quick Start Cod INSTUM_00953 Pag 22 To display the chart select Show Chart on the table with the right key of your mouse Enjoy your R Log...

Отзывы: