Care and Maintenance
60
MultiPress S
Operating manual 3.0
Rev: 3.6.2009
›
Prior to each use, check the machine, the hydraulik pump, all outer
wiring and the hydraulic hose for visible damage. Pay particular
attention to oil loss at the hydraulic connections and cracked and rub
spots on the wiring.
›
If any damage is recognized:
Make sure that the machine can not be used until the damage is
repaired.
Checking the oil-level
›
Finish any running programm (see "Canceling/Quitting the program"
›
Switch the main switch on the back of the MultiPress S to position
0
.
›
Wait at least about five minutes to let the oil set.
›
Srew off the lid from the filler neck of the automatic hydraulic pump
and pull out the measuring stick.
›
Check the oil level on the basis of the markers on the measuring
stick:
Fig. 24: Checking the oil
level
1
"Minimum" marker
2
"Maximum" marker
3
Oil measuring stick
4
Lid of the oil filler neck
5
Acceptable oil level (between markers)
3
1
2
4
5
Result
What to do?
Oil level is in between the
markers, oil level is acceptable.
Insert measuring stick into filler neck.
Fasten the lid by hand.
Oil level is below "Minimum"
marker, too less oil.
Refill hydraulic oil nachfüllen (see
"Changing/refilling hydraulic oil" on
Caution! Use approved oils only.
Oil level is above "Maximum"
marker, too much oil.
Drain excessive oil.
Содержание MultiPress S
Страница 2: ......
Страница 12: ...For your notes 10 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Страница 15: ...Table of contents MultiPress S Operating manual 3 0 Rev 3 6 2009 13 13 Index 73...
Страница 30: ...For your notes 28 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Страница 38: ...For your notes 36 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Страница 58: ...For your notes 56 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Страница 60: ...For your notes 58 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Страница 70: ...Technical Data 68 MultiPress S Operating manual 3 0 Rev 3 6 2009...