- Instruction Manual for ESS R050096 -
31
4.2.1 Main screen
The LCD is touch screen, below screen shows the overall information of the inverter.
(1)
The icon in the center of the home screen indicates that the system is Normal operation. If it
turns into “comm. /F01~F64”, it means the inverter has communication errors or other errors,
the error message will display under this icon (detail error info can be viewed in the chapter
5.3).
(2)
At the top of the screen is the time.
(3)
System Setup Icon, Press this set button, you can enter into the system setup screen which
including Basic Setup, Battery Setup, Grid Setup, System Work Mode, Generator port use,
advanced function and Li-Battery info.
(4)
The main screen showing the info including Solar, Grid, Load and Battery. It’s also displaying
the energy flow direction by arrow. When the power is approximate to high level, the color on
the panels will changing from green to red so system info showing vividly on the main screen.
(5)
PV power and Load power always keep positive.
◼
Grid power negative means sell to grid, positive means get from grid.
◼
Battery power negative means charge, positive means discharge.