137
Calibrate is highlighted on the device configuration menu (left). Cali-
bration menu (right) with calibration instructions listed at the top.
3-Point Calibration
3-point calibration is designed for tanks that vary in shape from the top
to the bottom. You can begin calibration at any point in the 3-point
process, but we recommend starting calibration with an empty tank.
In a 3-point calibration, you will set three points, one each for empty,
half and full levels.
1. Press
MENU| MENU
, use
↓
↑
to select
NMEA
2000
and press
ENT
.
2. Highlight
B
US
S
ETUP
and press
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page.
3. Select the EP-15 Fluid Level and press
ENT
.
4. Press
↓
to select
C
ALIBRATE
and press
ENT
. The Device Calibration
menu will appear.
5. Highlight
N
UM
P
TS
, press
ENT
and select
3
. Press
ENT
.
6.
Make sure your tank is empty, then highlight
F
LUID
L
EVEL
and press
ENT
.
Select
E
MPTY LEVEL
and press
ENT
.
7.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Empty Level Calibration Completed
. Press
ENTER
.
8.
Add half a tank of fuel, highlight
F
LUID
L
EVEL
and press
ENT
.
Select
H
ALF LEVEL
and press
ENT
.
9.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Half Level Calibration Completed
. Press
ENT
.
10. Fill up the tank, then
highlight
F
LUID
L
EVEL
and press
ENT
.
Select
F
ULL LEVEL
and press
ENT
.
11
.
Highlight
C
ALIBRATE
and press
ENT
. The following message will ap-
pear:
Full Level Calibration Completed
. Press
ENT
, then press
EXIT
re-
peatedly to get back to the main display.
Содержание GlobalMap Baja 840C
Страница 1: ...Pub 988 0160 441 www lowrance com GlobalMap Baja 840C Mapping GPS Receivers Operation Instructions ...
Страница 8: ...vi Notes ...
Страница 16: ...8 Notes ...
Страница 64: ...56 Notes ...
Страница 126: ...118 Notes ...
Страница 156: ...148 Notes ...
Страница 157: ...149 Notes ...
Страница 158: ...150 Notes ...