26
9.0
TROUBLESHOOTING
ERROR
CODE
ERROR
CATEGORY
CODE
DESCRIPTION
INDICATOR LAMPS
ON SWITCH
DIAGNOSTIC WINDOW
ON SOFTWARE
DIAGNOSTIC
SYSTEM BEHAVIOUR
TROUBLE AREA
ERROR REMEDY 1
ERROR REMEDY 2
ERROR REMEDY 3
P01
Communication
Error
Communication
missing
None
Pop UP window with er-
ror code and description
ECU doesn’t
communicate
USB-COM port (problem with PC Port)
Connectivity of Serial Interface or ECU
Functionality of Serial Interface or ECU
Check the connectivity of ECU (fuse &
power supply)
Check the connectivity and functionali-
ty of serial interface device
Check that the USB-COM
port of PC are running or
virtual N° device is number
from 1 to 9
Replace the ECU or the
PC or the Serial Interface
Device as the case
P02
Communication
Error
ECU is
incompatible
None
Pop UP window with er-
ror code and description
ECU doesn’t
communicate
ECU
Use a correct model of ECU
P03
Communication
Error
Can’t opening
Input Data File
None
Pop UP window with er-
ror code and description
Update fi rmware
not possible
Input Data File
Input Data File corrupted
Replace the fi le
Reinstall the Calibration
Software Tool
P04
Communication
Error
Error in decrypting
of fi le of
programming
None
Pop UP window with er-
ror code and description
Update fi rmware
not possible
Operation System on the PC
Check the version of Internet Explorer.
It’s requires the presence of Internet
Explorer version 5.5 or next, with en-
cryption at least 128 bit.
P05
Programming
Error
Wrong voltage of
programming
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
Internal ECU Power Supply
Check the power ECU supply and try
again to program ECU
Replace the ECU
P06
Programming
Error
Error cancelling
fl ash
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
ECU Microprocessor
Turn off the power supply and try
again to program ECU
Replace the ECU
P07
Programming
Error
Error during
initialization
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
ECU Microprocessor
Turn off the power supply and try
again to program ECU
Replace the ECU
P08
Programming
Error
Error during
initialization
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
ECU Microprocessor
Turn off the power supply and try
again to program ECU
Replace the ECU
P09
Programming
Error
Error during start
programming
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
ECU Microprocessor
Turn off the power supply and try
again to program ECU
Replace the ECU
P10
Programming
Error
Empty size of
input data
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
Input Data File
Input Data File corrupted
Replace the fi le
P11
Programming
Error
Wrong mode of
encryption
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
Input Data File
Input Data File corrupted
Replace the fi le
P12
Programming
Error
Generic
programming
error
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
ECU Microprocessor
Turn off the power supply and try
again to program ECU
Replace the ECU
From
P1000
to up
Programming
Error
Error during Re-
cord programming
None
Pop UP window with er-
ror code and description
ECU Programming
doesn’t run
ECU Microprocessor
Turn off the power supply and try
again to program ECU
Replace the ECU
C01
Connection
Error
Communication
missing
None
Pop UP window with er-
ror code and description
ECU doesn’t
communicate
USB-COM port (problem with PC Port)
Connectivity of Serial Interface or ECU
Functionality of Serial Interface or ECU
Check the connectivity of ECU (fuse &
power supply)
Check the connectivity and functionali-
ty of serial interface device
Check that the USB-COM
port of PC is running and
virtual N° device is number
from 1 to 9
Replace the ECU or the
PC or the Serial Interface
Device as the case
C02
Connection
Error
Error loading the
identifi cation data
of the ECU
None
Pop UP window with er-
ror code and description
ECU doesn’t
communicate
Connectivity of Serial Interface or ECU
Functionality of Serial Interface or ECU
Check the connectivity of ECU (fuse &
power supply)
Check the connectivity and functionali-
ty of serial interface device
Replace the Serial Interfa-
ce Device or the ECU as the
case
C03
Connection
Error
Firmware version
not compatible
None
Pop UP window with er-
ror code and description
ECU doesn’t
communicate
Firmware of ECU
Use the correct Input Data File
C04
Connection
Error
Software version
not compatible
None
Pop UP window with er-
ror code and description
ECU doesn’t
communicate
PC Software (calibration tool)
Upgrade the software version