            Doc: I491FGB05_17                                10/05/2017                                                  p. 10 / 12 

35 

kWh+ L1 Part – Énergie active L1 importée partielle 

 

 

35 

kWh+ L1 Part – Partial imported L1 active energy 

36 

kWh+ L2 Part – Énergie active L2 importée partielle 

 

 

36 

kWh+ L2 Part – Partial imported L2 active energy 

37 

kWh+ L3 Part – Énergie active L3 importée partielle 

 

 

37 

kWh+ L3 Part – Partial imported L3 active energy 

38 

kWh- Part – Énergie active exportée partielle 

 

 

38 

kWh-  Part – Partial exported active energy 

39 

kWh+ L1 Part – Énergie active L1 exportée partielle 

 

 

39 

kWh- L1 Part – Partial exported L1 active energy 

40 

kWh+ L2 Part – Énergie active L2 exportée partielle 

 

 

40 

kWh- L2 Part – Partial exported L2 active energy 

41 

kWh+ L3 Part – Énergie active L3 exportée partielle 

 

 

41 

kWh- L3 Part – Partial exported L3 active energy 

42 

kvarh+ Part – Énergie réactive importée partielle 

 

 

42 

kvarh+  Part – Partial imported reactive energy 

43 

kvarh+ L1 Part – Énergie réactive L1 importée partielle 

 

 

43 

kvarh+ L1 Part – Partial imported L1 reactive energy 

44 

kvarh+ L2 Part – Énergie réactive L2 importée partielle 

 

 

44 

kvarh+ L2 Part – Partial imported L2 reactive energy 

45 

kvarh+ L3 Part – Énergie réactive L3 importée partielle 

 

 

45 

kvarh+ L3 Part – Partial imported L3 reactive energy 

46 

kvarh- Part – Énergie réactive exportée partielle 

 

 

46 

kvarh-  Part – Partial exported reactive energy 

47 

kvarh+ L1 Part – Énergie réactive L1 exportée partielle 

 

 

47 

kvarh- L1 Part – Partial exported L1 reactive energy 

48 

kvarh+ L2 Part – Énergie réactive L2 exportée partielle 

 

 

48 

kvarh- L2 Part – Partial exported L2 reactive energy 

49 

kvarh+ L3 Part – Énergie réactive L3 exportée partielle 

 

 

49 

kvarh- L3 Part – Partial exported L3 reactive energy 

50 

kW d – Demande de puissance active 

 

 

50 

kW d – Active power demand 

 

Remarques : 

  

Quand les seuils sont appliqués à ces mesures, pour la comparaison, la 

mesure la plus élevée ou la plus basse parmi les trois phases est sélectionnée, 

selon que le seuil est un seuil maximal ou minimal. Par exemple, en appliquant un 
seuil maximal aux tensions de phase, il suffit qu'une seule des trois phases soit 

supérieure au seuil pour que ce dernier intervienne. 

 

 

 

Note: 

  

When thresholds are applied to these measurements, the comparison is made 

using the highest or the lowest among the three phases, depending on the type of 
threshold (maximum or minimum). For instance, applying a maximum threshold to 

the phase voltages, if any of the three voltages is above the limit, the threshold will 
be activated.

 

 

Disposition des bornes et dimensions mécaniques [mm]  

 

 

Terminal arrangement and  mechanical dimensions [mm]   

L3

L1

L2

L1

L2

L3

N

T2

T1

B

A

TR

SG

DME D301

Ener

gy

mete

r

1000

Imp/kWh

380-415 V3N~

50/60Hz

0.75-15 (80)A Cl. 0.5s

 

 

 

 

Schémas de branchement 

 

 

Wiring diagrams 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

100...240Vac

Tariff input 

LOAD

LINE

380-415 V3N

RS485 

Содержание DMED301MID

Страница 1: ...s Geräts befinden und vom Bediener leicht zugänglich sein Er muss als Trennvorrichtung für das Gerät gekennzeichnet sein IEC EN 61010 1 6 11 2 Das Gerät mit einem weichen Tuch reinigen keine Scheuermittel Flüssigreiniger oder Lösungsmittel verwenden ADVERTENCIA Leer atentamente el manual antes de instalar y utilizar el regulador Este dispositivo debe ser instalado por personal cualificado conforme...

Страница 2: ... measurement accuracy is compliant with reference standard EN 50470 3 Class B while the reactive energy with IEC EN 62053 23 Class 2 In addition to energy metering it can measure further quantities which can be viewed on the backlight LCD display The DME D301MID has a standard 4U 72mm wide modular housing and is supplied with sealable terminal blocks Description Boîtier modulaire 4U 72 mm pour rai...

Страница 3: ...L2 L3 Hz Fréquence 00 0 h Part Compteur horaire hhhhh mm 00000 00 L1 L2 L3 kW d Puissance active moyenne demande sur 15 min 00 00 kW d Max puissance active moyenne demande max 00 00 Selection of readings By pressing the keys it is possible to select the readings on the display following the sequence in the table reported below Each measurement unit is indicated by the correspondent icon in the low...

Страница 4: ...ce of imported and exported energy The pulsing rate of the LED gives an immediate indication of the power flowing in every moment The pulse duration colour and intensity of the LED are compliant with the reference standards that define its utilisation in order to verify the accuracy of the energy meter Indication du débit d énergie Quand un appareil détecte un débit d énergie vers la charge l écra...

Страница 5: ...if 1 Énergie Réactive Exp L3 2 kvarh 1000 1BFCh Tarif 2 Énergie Active Imp L3 2 kWh 1000 1C00h Tarif 2 Énergie Active Exp L3 2 kWh 1000 1C04h Tarif 2 Énergie Réactive Imp L3 2 kvarh 1000 1C08h Tarif 2 Énergie Réactive Exp L3 2 kvarh 1000 0002h Tension de Phase L1 2 V 100 0004h Tension de Phase L2 2 V 100 Modbus address table By modbus function 03 or 04 the following measures can be read from the d...

Страница 6: ...e peut être utilisée pour la sélection entre deux tarifs T1 et T2 avec compteurs d énergie séparés la mise à zéro des compteurs partiels des compteurs horaires et de la demande max en activant l entrée l activation du compteur horaire 0006h L3 Phase Voltage 2 V 100 0008h L1 Current 2 A 10000 000Ah L2 Current 2 A 10000 000Ch L3 Current 2 A 10000 000Eh L1 L2 Voltage 2 V 100 0010h L2 L3 Voltage 2 V 1...

Страница 7: ... clearing of partial energy meters CLEAR h simultaneous clearing of all 3 partial hour counters if enabled CLEAR d clearing of max demand values if enabled SET DEF set all parameters to default values SETUP programming of parameters set up INFO revision and checksum of internal software ESC return to normal operation 5 To select a function press while the required function is displayed For clearin...

Страница 8: ...marque les mesures sont mises à jour et intégrées 1 fois par seconde Remarque Si P2 02 P2 03 le compteur horaire s active quand la mesure spécifiée par P2 01 devient supérieure à P2 02 et se désactive quand elle redevient inférieure à P2 03 fonction de seuil maximal avec hystérésis Si au contraire P2 02 P2 03 le compteur horaire s active quand la mesure spécifiée par P2 01 est inférieure à P2 02 e...

Страница 9: ...l includes the harmonic contribution same vale as TOT case P08 01 Serial address node fot the communication protocol P08 02 Transmission speed of the communication port P08 03 Data format 7 bit settings possible only with ASCII protocol P08 04 Stop bit number P08 05 Communication protocol selection P7 02 Sélectionne la méthode de calcul pour la puissance réactive TOT la puissance réactive inclut é...

Страница 10: ...tial exported reactive energy 47 kvarh L1 Part Énergie réactive L1 exportée partielle 47 kvarh L1 Part Partial exported L1 reactive energy 48 kvarh L2 Part Énergie réactive L2 exportée partielle 48 kvarh L2 Part Partial exported L2 reactive energy 49 kvarh L3 Part Énergie réactive L3 exportée partielle 49 kvarh L3 Part Partial exported L3 reactive energy 50 kW d Demande de puissance active 50 kW d...

Страница 11: ...nt Iref Ib 15A Curant maximal Imax 80A Max current Imax 80A Courant de démarrage Ist 60 mA Start current Ist 60 mA Précision Accuracy Énergie active EN 50470 3 Classe B Active energy EN 50470 3 Class B Conditions de fonctionnement Ambient conditions Installation Uniquement pour usage interne Mounting Indoor use only Température d utilisation 25 55 C Operating temperature 25 55 C Température de sto...

Страница 12: ...0 49 Nm 4 4lbin Connexion interface série Serial interface connections Type de bornes À vis fixes Type of terminals Screw fixed Nbr de sorties 2 Number of outputs 2 Nbr bornes 4 Number of terminals 4 Section conducteurs min max 0 2 1 3 mm2 24 16 AWG Conductor cross section min max 0 2 1 3 mm2 24 16 AWG Couple de serrage des bornes 0 15 Nm 1 7lbin Tightening torque 0 15Nm 1 7lbin Boîtier Housing Ex...